NKT-N9 Nano Particle Size and Zeta Potential Analyzer

NegotiableUpdate on 07/10
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

NKT-N9 nano particle size and Zeta potential analyzer are widely used in the particle size characterization of organic or inorganic nano lotion, powders, polymers, micelles, virus antibodies, proteins and other samples in various fields such as new materials, pharmaceuticals, bioengineering, life sciences, chemicals, painting, food safety, and the dispersion and stability analysis of sample systems.

Product Details

NKT-N9 Nano Particle Size and Zeta Potential Analyzer

Range: 0.5nm-10000nm (depending on the sample)

Appearance dimensions: 440mm × 245mm × 228mm

Product features: Particle and molecular weight fiber coupled semiconductor laser, high-speed digital correlator, dual wavelength laser, one key switching ± 0.1% high-precision constant temperature control HAMAMASTU photomultiplier tube

NKT-N9 Nano Particle Size and Zeta Potential AnalyzerOverview Product Overview

NKT-N9纳米粒度及Zeta电位分析仪

The NKT-N9 series nanoparticle analyzer is a specialized analytical instrument used to characterize the particle size and distribution of nanoparticles. It is based on the principle of dynamic light scattering (DLS) and photon correlation spectroscopy (PCS) technology, using laser irradiation to uniformly disperse nanoparticles in a sample pool. The detection fiber receives the dynamic scattered light of the sample particles caused by Brownian motion at a 90 ° angle and transmits it to a photomultiplier tube (PMT) to convert the light signal into a discrete pulse signal. Then, the autocorrelation curve of the sample is obtained through a digital correlator, and the diffusion coefficient of the particles is obtained by combining mathematical methods. Finally, the particle size and distribution of the measured sample are calculated according to the Stokes Einstein equation.

Scope of Application

NKT-N9 laser particle size analyzer is widely used for particle size characterization of organic or inorganic nano lotion, powder, polymer, micelle, virus antibody, protein and other samples in various fields such as new materials, pharmacy, bioengineering, life science, chemical industry, coating, food safety, and the dispersion and stability analysis of sample systems.

Product Parameters

Measuring principle

Dynamic Light Scattering (DLS), Photon Correlation Spectroscopy (PCS), Static Light Scattering (SLS)

Particle size range

0.5nm-10000nm (depending on sample options)

detection angle

90º

test parameters

Particle size, molecular weight, second micro profit coefficient

Laser

Integrated constant temperature system with high power of 50mw, wavelength of 532nm or 405 solid-state laser (optional)

Correlators

512 physical channels, sampling time adjustable dynamically from 0.1us-1ms

Detector

Photomultiplier tube (PMT)

Filtering method

Light trap filtering

Accuracy error

Better than ± 1% (average particle size, NIS traceable standard sample)

repeatability error

Better than ± 1% (average particle size, NIS traceable standard sample)

Sample pool

12mm石英比色皿, 1ml-4ml

Test concentration within a small range

0.1mg/ml-40% w/v (depending on sample options)

Molecular weight testing range

340 Da-2 × 107Da (related to sample options)

Measuring speed

Less than 5 minutes per session

Temperature control range

5℃-90℃

Temperature control accuracy

±0.1℃

Light intensity adjustment range

0-100%, automatic adjustment

Environmental Requirements

5 ° C-45 ° C, 10% -85% relative humidity (no condensation)

working power supply

AC100V-240V@50Hz-60Hz ,DC12V/10A

Overall Dimensions

440mm×245mm×228mm

Instrument weight

9.5kg

Scope of Execution

GB/T29022-2021/ISO22412-2017 GB/T19627-2005/ISO13320-1996

Technical Explanation

NKT-N9纳米粒度及Zeta电位分析仪All fiber testing optical path creates high sensitivity

The test optical path constructed by coupling a high-performance low-noise fiber coupled semiconductor laser with an all fiber dynamic scattering light receiving system uses a HAMAMASTU photomultiplier tube (PMT) with low dark counting and high sensitivity as the photodetector, which enables the entire test system to have high sensitivity and signal-to-noise ratio, laying the foundation for testing accuracy and high resolution.

NKT-N9纳米粒度及Zeta电位分析仪High speed digital correlators achieve high resolution

The independently developed high-speed digital correlator is used as the core device for signal processing, which collects dynamic scattered light intensity in real-time and performs autocorrelation operation at high speed. It has the ability to recognize 6ns signal resolution, 100Mbps data processing speed, and a linear dynamic range higher than 1011, ensuring the integrity of autocorrelation curves for particles of different sizes throughout the entire range.

NKT-N9纳米粒度及Zeta电位分析仪Full range calibration verification to ensure testing accuracy

Multiple national particle size standard substances were used for calibration and verification within the full range, and the testing accuracy error was less than 1% (higher than the requirements of the national standard GB/T29022-2021/ISO22412:2017).

NKT-N9纳米粒度及Zeta电位分析仪High precision constant temperature control

The semiconductor laser with automatic constant temperature technology ensures stable and reliable laser output. The high-precision constant temperature control system keeps the tested sample in the sample pool in a constant temperature state throughout the entire testing process, avoiding test deviations caused by temperature changes in medium viscosity and particle Brownian motion speed, thereby ensuring the reliability and stability of the test results.


The same sample from the customer was prepared into 6 test samples for testing, with a repeatability error of less than 1% (higher than the requirements of the national standard GB/T29022-2021/ISO22412:2017)