Multi channel electrophysiological stimulation/acquisition system
Key Features:
● Record up to 1024 channels simultaneously;
● Maximum simultaneous independent electrical stimulation of 128 channels;
● Expandable 24 digital input/output channels;
● It can expand up to 6 analog inputs/outputs, flexibly set output waveforms, and can be used to modulate optogenetic signals/stimulus signals/behavioral signals;
● EEG signal simulator.

Strong isolated neural data input port
Designed for high-quality electrophysiological research. The stimulation and recording ports are electrically isolated from all other inputs and outputs to optimize signal quality and reduce noise.
TruGround (Strong Grounding)
Most systems are only equipped with one ground node, which is not suitable for in vivo electrophysiological recording. TruGround connects the ground wire and signal path to two separate nodes, significantly reducing noise in electrophysiological recordings.
Multi channel electrophysiological stimulation/acquisition system
Ultra comprehensive functionality
Switch ThornStimulate/Record:
XDAQ ™ The X-Headstage allows for direct selection and modification of stimulation and recording channels on the electrodes through software.
Self made electrode electroplating:
XDAQ equipped with SR stimulation/recording Headstage ™ It can perform fully automatic electroplating and impedance testing.
Short circuit analyzer:
XDAQ™Control the short-circuit analyzer to identify the short-circuit situation in the electrodes and Headstage.
TTL&DAC pulse generator:
XDAQ™It can drive digital and analog outputs and configure experiments in the way you want. Incorporating optogenetic stimulation, electrical stimulation, and behavioral controlManufacturing systems, etc.
Impedance test:
XDAQ ™ Can perform electrode impedance measurement with X-Headstage.
Cross compatibility:
XDAQ ™ Compatible with X-Headstage and Intan system hardware and software.
![]()
·Recording channel: 512/1024 (sampling rate 1-30 kHz);
·Electrical stimulation channel: 64/128;
- 10 nA-2.55 mA,33 μs steps;
-Constant current output voltage: ± 7V, 10Vto-4V, 4VTo-10;
·8X digital GPIO (3/5V compliant);
·2X analog GPIO (+/-10V, calibrated);
·Port isolation;
·TruGround;
·Heavy duty heat dissipation shell.

![]()
· Recording channel: 512 (sampling rate 1-30 kHz);
·Electrical stimulation channel: 16/32;
- 10 nA-2.55 mA,33 μs steps;
-Constant current output voltage: ± 7V;
·7X digital GPIO (3/5V compliant);
·IX Analog GPIO (+/-10V);
·Aluminum casing.