- Phone
-
Address
First Floor Factory Building, Area A, Fengshu Industrial Park, Dongfeng Avenue, Wuhan Economic and Technological Development Zone, Hubei Province
Wuhan Andexin Testing Equipment Co., Ltd
First Floor Factory Building, Area A, Fengshu Industrial Park, Dongfeng Avenue, Wuhan Economic and Technological Development Zone, Hubei Province

1Mobile large high-temperature aging boxProduct Usage
Used for aging testing of electronic, electrical, plastic, hardware and other products in high temperature environments, detecting the product's performance
Performance stability under long-term high temperature conditions, such as whether components fail, materials deform or age.
Test the temperature resistance, oxidation resistance, and strength of various materials (such as rubber, plastic, coatings, etc.) in high temperature environments
Evaluate the high temperature resistance and service life of materials based on changes in temperature.
IIMobile large high-temperature aging boxBasic characteristics of equipment
1. The structural design of the experimental system should be excellent and reasonable, with standardized manufacturing processes and a beautiful and elegant appearance.
2. The main functional components of the laboratory should adopt world-class configuration (high gold content) and excellent technical principles
Reliability, optimal control of noise and energy efficiency.
3. The matching and assembly of components are good, and the main functional components should be imported to improve the equipment
The safety and reliability of the backup ensure that users can meet their long-term and high-frequency usage requirements.
4. The equipment should have good operability, maintainability, good temperature stability and durability, and good safety
Performance, non polluting environment, and harm to personal health.
3、 Main technical indicators
1. Internal dimensions: W1500mm * H1900mm * D1300mm (customized according to customer requirements)
2. External dimensions: W2000mm * H2350mm * D1500mm (customized size according to customer requirements)
3. Temperature range: RT+10 ℃~80 ℃;
4. Temperature fluctuation: ± 0.5 ℃;
5. Heating rate: from room temperature to 80 ℃ ≤ 30 minutes;
6. Temperature uniformity: ± 2 ℃;
7. Box material: The inner box is made of SUS201 # stainless steel, and the outer box is made of steel plate baked paint (color code RAL7035);
8.保温材料:高密度岩棉防火材料,厚度 75mm;
9. Box door: Install one double door, 2000mm (W) * 2025mm (H), with a conductive film tempered glass on each door
Glass observation window, equipped with a safety door locking mechanism;
10. Reserve two 100mm power test holes;
11. Configure a USB computer connection port for printing reports and outputting data;
12. Apply anti slip treatment to the bottom of the laboratory;
13. The aging room is delivered as a whole, meeting the requirements of rapid installation
4、 Safety protection and electromagnetic compatibility requirements
1. This test box should meet the national electrical safety standards, wiring specifications, and all wiring ports should be clearly marked as exposed;
2. The studio is absolutely insulated from all power sources, with a resistance greater than 1M Ω and no accumulation of static electricity;
3. * Security protection function (as follows)
1) Reliable grounding protection device;
2) Leakage/circuit breaker protection;
3) Heater short circuit/over temperature protection;
4) Circulating fan overcurrent protection; 5) Studio overheating protection; 6) Phase sequence and phase loss protection;
4. Electrical equipment meets the requirements of relevant electromagnetic compatibility standards;
5. The door should ensure dual opening both inside and outside, allowing for easy access at any time;
5、 Equipped with technical data and attachments
1. Technical data: third-party measurement report, equipment qualification certificate, equipment maintenance manual, electrical schematic diagram
Warranty card and instrument manual.
2. Communication software CD for upper computer, etc.
6、 After sales service
1. Provide detailed usage and maintenance instructions, including easy component models, brands, manufacturers, replacement frequency, and disassembly
Dismantling and installation methods.
2. Provide operational training to the user unit upon initial delivery of the equipment.
3. The quality assurance period is 2 years, starting from the date of formal delivery and use;
4. During the warranty period, except for damages caused by natural disasters, abnormal electricity, improper human use, improper maintenance, and other factors,
Free maintenance is required;
5. Provide free consultation on usage and maintenance as needed;
6. Timely provide vulnerable parts and spare parts, and provide spare parts for life;
7. During the operation of the test chamber, if there is a malfunction in the test system, a response should be given immediately upon receiving notification, and
Assist in equipment testing and maintenance within 24 hours to ensure normal operation of the equipment;
After the warranty period, lifetime maintenance is provided, and maintenance and material costs may be charged at a discretion