Microplate specific constant temperature oscillator

NegotiableUpdate on 01/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The microporous plate specific constant temperature oscillator is a multi-purpose constant temperature oscillator that combines a DC brushless motor and PID intelligent temperature control technology. Its PID control technology can accurately ensure temperature control accuracy and automatically adjust heating rate to save waiting time. Combining the functions of constant temperature and oscillation greatly shortens the experimental operation time, making it an ideal automation tool for sample incubation, catalysis, mixing, and preservation processes.

Product Details

Microplate specific constant temperature oscillator/Microplate constant temperature oscillator/96 well enzyme-linked immunosorbent assay plate mixer/96 well plate heating mixer

Model:H18433

Microplate specific constant temperature oscillatorIt is a multi-purpose constant temperature oscillator that combines a brushless DC motor with PID intelligent temperature control technology. Its PID control technology can accurately ensure temperature control accuracy and automatically adjust heating rate to save waiting time. Combining the functions of constant temperature and oscillation greatly shortens the experimental operation time, making it an ideal automation tool for sample incubation, catalysis, mixing, and preservation processes.


This product has the following characteristics
1. A simple and easy-to-use human-machine interface that displays all operational and setup information in real-time, making it convenient for users to observe the device's operating status;
2. It can process 4 enzyme-linked immunosorbent assay plates or deep well plates at once;
3. Adopting DC brushless motor, low noise, minimal interference, and maintenance free;
4. Adopting hot lid heating technology;
5. Support automatic preheating function;
6. Support automatic power failure recovery function;
7. Comes with temperature calibration function;
8. Built in software and hardware dual over temperature protection device, making it more reliable to use.


Normal working conditions
Operating environment temperature: 0C 35C
Relative humidity: ≤ 70%
Power supply: AC220V/50-60HZ


Basic Parameters
Temperature setting range: 0 ℃~80 ℃
Temperature control range: Room temperature+5 ℃~80 ℃
Time setting: 1min~99h59min/∞
Temperature control accuracy: ≤± 0.5 ℃*
Display accuracy: 0.1 ℃
Temperature uniformity: ≤± 0.5 ℃*
Speed range: 200~1350rpm
Horizontal amplitude: 3mm
Heating time: ≤ 15 minutes (heating from 25 ℃ to 80 ℃)*
Automatic preheating: supported
Power off automatic recovery: supported
Sample capacity: 4 enzyme-linked immunosorbent assay plates or deep well plates
Input power: 300W
Voltage: AC220V/50-60HZ
melt sever Device: 250V 3A Ø 5 × 20
Dimensions (mm): 340x320x200 mm
Weight: 9.5Kg
*Test conditions: Room temperature 25 ℃± 2 ℃, thermometer accuracy ± 0.1 ℃





2.Mineral wool needle thickness gauge/needle thickness gauge/rock wool thickness gauge/needle thickness gaugeH18431

Measurement range 0-140mm
Pressure plate size 200 * 200
Pressure plate pressure 50 ± 1.5Pa
Measuring needle diameter Φ 3mm
Division value 1mm
Dimensions 200 * 200 * 180mm

Usage:
Place the test sample flat on a hard flat plate, loosen the tightening nut at the bottom of the measuring needle, gently place the instrument on the test sample, slowly insert the measuring needle into the test sample until it reaches the bottom, and check the thickness indicated by the parallel position of the scale pointer slider, which is the thickness of the test sample.

3.Handheld transmittance meter/car solar film transmittance detection/plastic film glass detection meter/haze meter/transmittance meterH18431

The transmittance meter series adopts a parallel light path design, and the instrument will automatically calibrate and measure upon startup; Place the test material into the testing slot, and the screen will immediately display the test results; pressHOLDPress the key to lock the test data; Digital display, capable of measuring ultraviolet light, visible light, infrared light940nmand1400nmThe light transmittance. Widely used in industries such as film and glass.

4.Aquatic virus detection instrument/fish virus detection instrument/aquatic disease detection instrumentH18430

The aquatic virus detection instrument, also known as the fish virus detection instrument, is based on PCR fluorescence probe technology. It identifies the presence of viruses through changes in fluorescence signals and is used to detect the virus content in fish and shrimp in aquatic products. The aquatic virus detection instrument has the characteristics of simple use, easy operation, and easy control. It can quickly detect viruses in aquatic products such as fish and shrimp, achieving timely diagnosis and control.

1、 Characteristics of Aquatic Virus Detection Instruments

1. Small size, light weight, and easy to carry. Easily meet the needs of outdoor experiments.

2. Built in 7-inch high-definition capacitive screen PDA, touch screen operation, simple and fast.

3. Marlow high-quality Peltier refrigeration chips, combined with German PT1000 temperature sensor and temperature control mode with electric resistance heating compensation edge, have a heating rate of 7 ℃ and a large cooling rate of 5 ℃, greatly reducing experimental time.

4. The whole board adopts a 3-second fast lighting mode to ensure the consistency of the hole positions in the experimental results.

5. Simple and intuitive software guidance, making it easy to start detection experiments.

2、 Application fields of aquatic virus detection instruments

Basic scientific research

pathogen detection

Meat products adulterated

Transgenic testing

Food safety testing

Drug development and rational drug use

gene expression

Water monitoring

3、 Technical parameters of aquatic virus detection instruments

Sample capacity: 8x0.2ml, supports 8-tube connection

Applicable consumables: Common transparent PCR consumables, 8x0.2ml tube, 0.2ml single tube

Reaction system: 5-120ul reaction mode system

Heating/cooling module: imported semiconductor thermoelectric module

Temperature control range: 4 ° C-99 ℃

The average rate of temperature rise and fall is ≥ 2 ° C/second

Temperature control accuracy: ≤± 0.1 ° C

Temperature uniformity: ≤± 0.2 ° C

Number of temperature control areas: Multiple points (2 points)

Number of gradients: 0

Gradient temperature range: none

Number of gradient holes: none

Excitation light source: maintenance free LED

Excitation light wavelength range: 400-700nm

Testing component: Imported photoelectric detector

Number of detection channels: standard configuration 1 channel (FAM), high-end configuration (optional) (FAM, VIC)

Applicable dyes and probes: FAM/SYBR Green I, VIC/HEX/CY3 (optional), ROX/Texas Red (optional), Cy5, TAMARA (optional)

Software function: Fluorescence quantitative PCR system software; Real time amplification reaction curve function; Real time response curve display of specific specimens; Data analysis function;

Automatic judgment function for yin-yang results; Graphic display function.

Noise:<45 dB

Screen size: 7 inches (HD)

Touch screen: capacitive type

External USB: Supports data import and export

Hot cover: automatic pressure regulation

Exterior dimensions: 290 (W) * 308 (L) * 130 (H)

Box size: 75 cm in length, 38 cm in width, and 19 cm in height

Net weight: approximately 3Kg

5.Evaporation sensor/evaporation rate sensor/water surface evaporation sensorH18429

1、 Working principle of evaporation sensor

The evaporation sensor is an instrument used to observe water surface evaporation, with high accuracy, sensitivity, and wide range. It adopts a double-layer stainless steel structure design to prevent evaporation errors caused by direct sunlight. The pressure measurement principle is applied to measure the weight change of liquid in the evaporation dish, calculate the page height, and thus measure the evaporation amount. The water surface evaporation measurement that can adapt to various environments is not affected by liquid freezing, overcoming the drawbacks of inaccurate measurement when using ultrasonic principle to measure liquid level height due to freezing, easy damage to sensors when there is no water, and low measurement accuracy.

2、 Scope of application of evaporation sensor

Water surface evaporation sensor is a sensor used to sense changes in water surface evaporation, which can observe the changes in water surface evaporation at different time periods. It is suitable for meteorological observation, plant cultivation, seed cultivation, agriculture and forestry, geological survey, scientific research and other fields.

It can be used in conjunction with automatic water adding devices, data collection and transmission devices, etc. to achieve automatic monitoring of the evaporation process. It can also be combined with data collection and storage devices (recorders) to achieve automatic storage of evaporation data. It can also be used in conjunction with rainfall sensors, data collection and transmission devices, etc. to achieve automatic observation and remote transmission of evaporation and rainfall processes.

3、 Functional characteristics of evaporation sensor

1. It can prevent evaporation errors caused by direct sunlight and has a fast response speed;

2. The whole machine is made of 304 stainless steel material, which is corrosion-resistant and does not rust, ensuring the service life of the sensor;

3. Pressure based measurement principle, using high-precision weighing principle to measure the weight change of the liquid in the evaporating dish, calculate the liquid level height, and thus measure the evaporation rate more accurately and scientifically;

4. The design structure of double-layer protection adopts a double-layer stainless steel design, which can isolate external interference and ensure accurate measurement results;

5. After a power outage, power is restored and the output data remains correct;

4、 Working and storage conditions of evaporation sensor

Working temperature: -40 to 85 ° C

Working humidity: 0-100% RH

Storage humidity:<80% (no condensation)

5、 Technical parameters of evaporation sensor

Power supply voltage: 12V DC

Measurement range: 0-190mm

Measurement accuracy: ± 1%

Signal output: 485 Modbus RTU

Response time: 200ms

Inner barrel diameter: 200mm

Protection level: IP66