Overview
The fully automatic EVOL cell is a microbial domestication equipment developed based on high gas permeability microchannels and single-phase microfluidic technology
Product Details

毫升体系微生物适应性进化仪

1、 Product Introduction

Fully automatic microbial adaptive evolution instrumentEVOL cell is a microbial domestication equipment developed based on high gas permeability microchannels and single-phase microfluidic technology. It has functions such as microbial cultivation, passage, chemical factor gradient addition, real-time detection, and oxygen partial pressure control. The instrument uses microchannels as miniature bioreactors, which have good permeability to various gases (oxygen, nitrogen, carbon dioxide, etc.), fully meeting the gas exchange requirements during the cultivation process. The fully automatic microbial adaptive evolution instrument utilizes oxygen partial pressure control technology to flexibly regulate the gas environment around the reactor, thus being applied to the cultivation and adaptive evolution of various microorganisms.

2、 Product Features

Tubular bioreactor

High gas mass transfer capacity

Weak fluid shear force

Fully automatic passage operation

OD、 Real time fluorescence detection

Adjustable and controllable oxygen partial pressure

3、 Product parameters

classification Technical Specifications
Tubular bioreactor Multiple gas highly permeable composite materials, reactor volume 5mL (linear amplification)
OD detection 350-800nm full wavelength detection, detection linear range 0-18
temperature control Room temperature+5 ℃ -50 ℃, resolution 0.1 ℃, fluctuation ± 0.5 ℃
Passage method Support two ways of passage: time-based passage and OD threshold passage
Inoculation volume for successive generations 1% -20% adjustment
Oxygen partial pressure environment control (optional) Oxygen control range 1-60%, nitrogen control range 1-60%, carbon dioxide control range 1-60%, fluctuation value 0.3
Chemical factors Support the addition of two chemical factors and the free setting of evolutionary gradients
Cultivate flux Host+N cultivation channels, supporting up to 4 channels, each channel independently controlled
4、 Workflow
毫升体系微生物适应性进化仪Comparison of oxygen mass transfer coefficients in different micro bioreactors
cultivation method Working volume/mL Temperature/℃ Vibration/stirring speed/rpm KLa/h-1
48 hole plate 0.9 34 200 (oscillation radius 25 mm) 102
shaking flask 15 34 200 (oscillation radius 25 mm) 103.48
Biolector 0.2-1 37 100-500 (oscillation radius 25 mm) 63.6-140
ambrTM15 10-15 37 300-1000 (flow rate 0.4-0.57 m/s) 2.6-6
EVOL cell 5 37 —— 100(air)