Merieux API NH Neisseria and Haemophilus Identification Kit
Packaging specifications10 tests/box
Testing principleAPI NHThe test strip is composed of10 Composed of a substrate containing dry powder. These substrates can be used for12 An appraisal test(Enzyme reactions andSugar fermentation)And testing(Especially in cases of Haemophilus influenzae, Haemophilus parainfluenzae, Klebsiella pneumoniae, and Neisseria gonorrhoeaeShigella).The reaction results after cultivation can be obtained from natural discoloration or by adding reagents.cultivate2 After hours, the reaction results can be observed with the naked eye, and the identification results can be compared with the identification table or corresponding identification software.
Composition of reagent kit
Main reagent:
API NH1 copy of operation manual
Operation guide card1 copy
10 copies of API NH report
10 API NH reagent strips
10 incubators (including lid)
Additional reagents:
NACL 0.85% medium10 ampoules
ZYMB reagent1 ampoule
James reagent 1 tube
10 disposable sample tubes
10 disposable cotton swabs
1 bottle of No.4 Maxwell turbidity tube
Composition and storage conditions of test strips
API ListeriaPlease refer to the instruction manual for the interpretation of the composition of the test stripTable. The test strip should be stored within its validity period (indicated on the reagent kit)stored in2-8℃.Once the aluminum bag containing the test strip is opened, a sealing clip should be usedSeal it to store the remaining test strips.
All reagents should be stored in the dark2-8Under a temperature of ℃ until the expiration date.
All ampoules have a validity period of only one month (or packaging) after openingThe validity period is based on the shortest possible time. Please carefully record ampoulesOpening time.
After opening the reagent ampoule or transferring the reagent into a dropper, it can be stored15 Valid within days (or until the expiration date), the date of opening the reagent bottle should be markedOn the bottle.ZYMBReagent sensitivity to light: After mixing the dropper bottle, check the appearance of the reagent.Put it back in the refrigerator immediately after use.ZYMBThe reagent should be within its validity periodYellow, the reagent has turned dark pink, please discard. Laboratory lightingThe reagent is damaged, try to shorten the time as much as possible (about)1Hour).
Merieux API NH Neisseria and Haemophilus Identification Kit