Technical Specifications
|
·Measurement range
|
Minimum measurement range of relative pressure (0-100) KPa; Maximum measurement range (0-4) MPa
|
|
|
|
Minimum measurement range of absolute pressure (0-100) KPa; Maximum measurement range (0-4) MPa
|
|
|
|
Minimum measurement range of negative relative pressure (-50~50) KPa; Maximum measurement range (-0.1~3.5) MPa
|
|
|
·Measurement accuracy
|
The comprehensive error (including linearity, repeatability, and hysteresis) is better than 0.05%,
|
|
|
|
2: 1~20:1 Range ratio: (0.05%+0.01% × TD)% Set range FS
|
|
|
·Long term stability
|
Exceeding 0.05% F.S annually
|
|
|
·Allowable medium temperature
|
(-40~120)℃
|
|
|
·Allow ambient temperature
|
(-20~80)℃
|
|
|
·Allow storage temperature
|
(-30~70)℃
|
|
|
·Temperature influence
|
Full temperature range impact ≤± 0.5% FS (compensating temperature (0-50) ℃)
Compared to 25 ℃
|
|
|
·Damping
|
0~40S continuously adjustable
|
|
|
·Anti vibration
|
Peak amplitude 0.07mm, frequency (10-60) Hz
|
|
|
·Impact resistance
|
50g 11mesc
|
|
|
·Electromagnetic compatibility characteristics
|
Compliant with IEC801 standard
|
|
|
·Sensors allow for overvoltage
|
3 times the standard range pressure
|
|
|
·Signal output
|
4-20mA linear output two-wire system with HART communication protocol
|
|
|
·Start time
|
3S without preheating required
|
|
|
·Contact with medium
|
Process connector: Stainless steel 316
|
|
|
Partial materials
|
Sensor diaphragm: stainless steel 316
|
|
|
·Non contact with the medium
|
Shell: Die cast aluminum strip with epoxy resin coating
|
|
|
Partial materials
|
|
|
|
·On site display
|
Five digit digital LCD display
|
|
|
·Electrical connection
|
M4 screw terminal block
|
|
|
·Power supply
|
Standard type: (12~36) V DC
|
|
|
|
Intrinsic safety type, explosion-proof type: (12~30) V DC
|
|
|
·Process Connection
|
External thread M20 * 1.5; G1/2; Or special requirements agreed upon
|
|
|
·Process connection material
|
Stainless steel 304/316L
|
|
|
·Protection level
|
IP66
|
|
|
·Explosion proof grade
|
Explosion proof Ex d Ⅱ C T6 Gb, intrinsically safe Ex ia Ⅱ C T6 Gb
|
|
|
·Allow environmental humidity
|
100%RH
|