MSG5100B pressure transmitter
|
working principle
|
Adopting micro melting technology and introducing aviation application technology, using high-temperature glass to melt micro machined silicon varistor strain gauges
|
|
|
On the stainless steel isolation membrane. The glass bonding process avoids the effects of temperature, humidity, mechanical fatigue, and medium on the adhesive and
|
|
|
The influence of materials has improved the long-term stability performance of sensors in industrial environments, while also avoiding sensing
|
|
|
The P-N junction effect phenomenon that occurs in traditional micro machining manufacturing process engineering.
|
|
Technical Specifications
|
·Measurement range
|
Relative pressure: minimum measurement range(0~0.1)MPa,Maximum measurement range(0~70)MPa
|
|
|
|
Negative relative pressure: minimum measurement range (-0.1~0.1)MPa; Maximum measurement range (-0.1~70)MPa
|
|
|
·Measurement accuracy
|
1%FS (including linear, hysteresis, and repeatability)
|
|
|
·Long term stability
|
Every year ≤±0.25%FS
|
|
|
·Allow ambient temperature
|
-40℃~+85℃
|
|
|
·Allowable medium temperature
|
-40℃~+125℃
|
|
|
·Allow storage temperature
|
-40℃~+125℃
|
|
|
·Temperature influence
|
1.0%, 0.5% accuracy: compensating temperature from 0 ℃ to+50 ℃, with a full temperature range impact of ≤± 0.75%
|
|
|
|
0.25% accuracy: compensation temperature -20 ℃~+60 ℃, full temperature range impact ≤± 0.5%
|
|
|
|
Or special requirements agreed upon
|
|
|
·Signal output
|
(4-20) mA analog type (two-wire system)
|
|
|
|
(0.5-4.5) V DC (three wire system)
|
|
|
|
(0-10) V DC (three wire system)
|
|
|
·Process Connection
|
External thread G1/4
|
|
|
·Anti vibration
|
20g (20~200Hz)
|
|
|
·Impact resistance
|
200g/11ms
|
|
|
·Working power supply
|
(4-20) mA output type (12-30) V DC;(0.5-4.5) V DC output type:5V DC
|
|
|
·Material of the part in contact with the medium
|
|
|
|
17-4PH stainless steel
|
|
|
·housing material
|
Stainless Steel 304
|
|
|
·Protection level
|
Aviation plug IP65; Overall cable IP65;
|
|
|
·Electromagnetic compatibility interference
|
EN61000-6-1,EN61000-6-310V/m
|
|
|
·Electrical connection
|
Overall cable type; Aviation plug-in type
|
|
|
·Pressure cycle
|
>107 full-scale cycles
|
|
|
·Other parameters
|
Overload pressure 2 times the rated pressure
|
|
|
|
Breaking pressure 5 times rated pressure
|
|
|
|
Explosion proof Ex d IIC T6 Gb
|
|
|
|
Load impedance: Current output RLMAX [Ω] ≤ (US-12V)/0.02A
(RLMAX [Ω] ≤ 600 Ω at 24V, RLMAX [Ω] ≤ 900 Ω at 30V)
Voltage output RLmin [Ω] ≥ 5 k Ω
|
Exterior structure
When installing instruments, it is forbidden to rotate the aviation plug with hands or tools!
electrical connection

In environments with strong interference, in order to ensure the normal operation of instruments, they should be reliably grounded according to relevant instrument grounding technical specifications!
Order Selection Table