Large capacity mold incubator MJX-1000

NegotiableUpdate on 01/27
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The MJX-1000 large capacity mold incubator has a precise temperature and humidity control system, which can provide various environmental simulation conditions required for industrial research and biotechnology testing. It is suitable for environmental protection, health and epidemic prevention, drug testing, agriculture, animal husbandry, aquaculture and other scientific research, universities, production departments, and is a specialized constant temperature and humidity equipment for water quality analysis and BOD testing, breeding experiments, and plant cultivation.
Product Details

Large capacity mold incubator MJX-1000Main features:

1. Temperature control adopts microcomputer intelligent temperature control, PID control, and both set and actual parameters can be accurately displayed, ensuring precise and reliable control. And it has temperature time adjustment function, temperature correction function, power-off protection function, ultra-low and high temperature alarm function.

2. Three dimensional heating, fan forced convection circulation, using forced convection ducts to circulate the air inside the box, ensuring uniformity of temperature and humidity. After opening the door, the temperature and humidity can quickly recover.

3. The outer surface is treated with electrostatic high-temperature spraying, and the workshop is made of high-quality mirror stainless steel plate with strong corrosion resistance;

4. The outer door is sealed with a magnetic seal, and the double-layer insulated glass observation door has good sealing and is easy to close for direct observation of the culture inside the studio.

5. Adopting high-quality brand fully enclosed compressors and fluorine free green environmentally friendly refrigerants, with high efficiency, low energy consumption, delayed start-up, and automatic high and low pressure protection.

6. The over temperature tracking alarm system provides reliable protection for the sample, automatically memorizes the set parameters, and can automatically recover after power interruption.

7. LCD display controller, which displays both parameter settings and actual operating values to meet daily experimental needs.

8. It can set the running time, with a timing range of 0 to 9999 minutes or hours, and can automatically shut down.

9. It has a 30 stage temperature control program, divided into 99 stages per week, to meet daily experimental needs.

10. The box is equipped with multiple layers of pull-out partitions, and the floor height can be adjusted according to specific needs.

11. The bottom of the box is equipped with four movable double wheel casters to facilitate the movement of the box.

12. There is a UV sterilization lamp on the top of the box, which has the function of UV lamp sterilization

大容量霉菌培养箱MJX-1000


Large capacity mold incubator MJX-1000Technical Specifications

Model: MJX-1000

Capacity: 1000L

Temperature control range: 0-50 ℃

Temperature fluctuation: ± 1 ℃

Temperature display resolution: 0.1 ℃

Temperature uniformity: ± 1.5-2 ℃

Opening method:double door

UV sterilization lamp: available

Lighting: Yes

Timing range: 0-999 minutes or hours

Inner container size: 1200 * 670 * 1200mm

Dimensions: 1300 * 790 * 1800mm

Daily maintenance points:
1. Use the bottom adjustment screw of the intelligent mold incubator to adjust the height and make the incubator settle and shake.
When inserting into a power socket, the power supply should be well grounded. Press the power door, and the display screen will light up. At this time, the display screen will show the actual temperature and humidity inside the incubator.
2. The device of the intelligent mold cultivation box humidifier is to insert the power socket of the humidifier into the power socket on the back of the instrument, and then connect the humidification tube of the instrument to the humidifier, which must be tightly connected. The addition of water to the humidifier water tank must be operated accurately according to the instructions.
3. Intelligent mold incubator humidity adjustment: Press the humidity setting knob. The number is displayed as the set value. Surround the humidity control flood level gauge to the desired humidity level. Grasp the knob and the number displays the actual humidity of the smart mold incubator. When the actual humidity in the cultivation room is higher than the set humidity, humidification will humidify the cultivation room, and the humidification indicator light will turn on; When the actual humidity in the cultivation room is higher than the set humidity value, the humidifier stops working and the humidification indicator light goes out.
If the box does not require disinfection, the disinfection door on the panel should be closed.
5. After setting the temperature, it is not allowed to wrap the temperature control button one way at will to avoid the compressor repeatedly starting, causing compressor overload and reflecting the service life of the compressor.
6. There are two sets of safety boxes on the back of the intelligent mold incubator. 2A is the safety wire box for cooling and heating loads, and 8A is the safety wire box for control power supply. If there is a malfunction in the operation of the tool, such as a temperature control failure, if there is no heating or cooling, the flow source must be cut off, the safety wire must be confirmed to be intact, and the corresponding position must be checked.
7. Be careful when loading and unloading, and the angle between the loading and unloading and the degree surface should not be less than 45 degrees.
When the temperature is low, the drain in the drain pan located at the bottom of the box should be poured out.
When the humidity sensor is in a high humidity state for a short period of time, condensation will form, resulting in a high humidity display value. If the desired humidity display value is required, the light should be turned off, the incubator door should be opened, and the humidity sensor should be at room temperature. After drying, it can continue to be used.