The angular rotor of the NACHT high-capacity high-speed desktop freeze centrifuge has a large capacity of 6 x 500 ml, and the horizontal rotor has a large capacity of 4 x 750 ml. The D-16R has a powerful refrigeration system that can quickly and accurately cool the sample, and can pre cool the rotor in a stationary state.
NACHT D-16RLarge capacity high-speed desktop freeze centrifugeProduct Introduction
NACHT D-16 and D-16R are large capacity desktop freeze centrifuges, with angular rotors having a large capacity of 6 x 500 ml and horizontal rotors having a large capacity of 4 x 750 ml. D-16R has a powerful refrigeration system that can quickly and accurately cool samples and pre cool the rotors in a stationary state.
Reminder: This product is not a medical device and is not intended for use in the medical field.
Application example:
Ultra large batch processing of DNA and RNA
Cell collection in cell culture or fermentation applications
food technology
Technical specifications:
| parameter | D-16 | D-16R |
| High speed | 14,000 rpm | 16,000 rpm |
| Large relative centrifugal force | 21,912 x g | 28,621 x g |
| large capacity | 4 x 750 ml | 4 x 750 ml |
| Low RPM | 100 rpm | 100 rpm |
| display screen | 5-inch LCD display screen | 5-inch LCD display screen |
| motor | Three phase asynchronous variable frequency motor, unbalanced protection, over temperature protection | Three phase asynchronous variable frequency motor, unbalanced protection, over temperature protection |
| timer | 10 seconds to 99 hours and 59 minutes, instantaneous | continuous operation | 10 seconds to 99 hours and 59 minutes, instantaneous | continuous operation |
| temperature range | - | -20°C ~ +40°C |
| rapid cooling | - | Rapid cooling program; Ensure that the temperature is below 4 ° C at high speeds; Rotor cooling can be achieved in standby mode |
| coolant | - | Fluorine free environmentally friendly refrigerant |
| Program storage | 50 | 50 |
| Acceleration curve | 19 | 19 |
| Deceleration curve | 19 | 19 |
| Opening method | Electric locking hood, automatic opening, emergency opening | Electric locking hood, automatic opening, emergency opening |
| hood | Observation hole allows for external observation of rotational speed | Observation hole allows for external observation of rotational speed |
| rotor | Automatic identification of rotor | Automatic identification of rotor |
| Dimensions (length x width x height) | 670 x 540 x 463 mm | 670 x 760 x 463 mm |
| weight | 90 kg | 130 kg |
| Noise at high rotational speed | <70 dB | <68 dB |
Attachment:
| Order number | type | description | High speed/large centrifugal force |
| D-16 | host | Host 220-240 V 50 Hz 900w | 16,000 rpm 21,912 x g |
| D-16R | host | Equipped with a refrigeration host 220-240V 50 Hz 1050w | 16,000 rpm 28,621 x g |
| D-14802 | Angular rotor | 48 x 1.5|2.0 ml | 16,000 rpm 28,621 x g |
| D-11002 | Angular rotor | 100 x 1.5|2.0 ml | 9,600 rpm 17,032 x g |
| D-10850 | Angular rotor | 8 x 50 ml | 14,000 rpm 21,913 x g |
| D-106100 | Angular rotor | 6 x 100 ml | 14,000 rpm 24,038 x g |
| D-106250 | Angular rotor | 6 x 250 ml | 10,500 rpm 17,873 x g |
| D-21696 | Enzyme linked immunosorbent assay plate rotor | 16 x 96 well enzyme-linked immunosorbent assay plate | 5,100 rpm 5,002 x g |
| D-204750 | Horizontal rotor | Horizontal rotor+4 x 750 ml (basket) | 4,700 rpm 4,692 x g |
| | adapter | 1 x 500 ml 1x 250 ml 3 x 100 ml 5 x 50 ml 15 x 15 ml 12 x 10 ml Other specifications of adapters can be customized | |
Note: | The above data are D-16R parameters, D-16 can be consulted. |
Centrifuge maintenance rules:
(1) One rule
When the system malfunctions, you can tentatively change certain states, one parameter at a time. By making some simple changes, perhaps the problem can be solved.
(2) Secondary comparison rule
Before starting the manual maintenance, the fault location has been identified or a solution to the problem has been determined. In other words, the solution has already been found before taking action. For example, if it is found during the injection process that the peak value of the internal standard has decreased, the injection can be repeated to check the repeatability. If it is an accidental decrease, it may be due to bubbles entering the quantitative tube. This rule can be used to examine the situation after system changes. After changing the flow, two standard samples can be injected before formal injection to check the stability of retention time and chromatographic peaks. If there are excess peaks in the gradient elution, it is possible to empty the gradient elution once (is there really a problem?). Using this rule can avoid unnecessary changes and determine corrective measures as soon as possible.
(3) Replace the rules
Replacing suspicious components with good ones is a good way to identify faults. If you suspect that the detector is causing noise, replace it with a high-performance rotorless vulcanizing analyzer detector. If the fault is eliminated, it means that there is a problem with the replaced detector. The scale of application of this rule varies, ranging from replacing entire components to replacing integrated blocks on printed circuit boards.
(4) Change back rules
This rule, when applied together with the replacement rule, did not improve the situation after replacing the suspicious component of the solution flow rate tester with a good component, and the original component should be replaced. This approach reduces maintenance costs and prevents the accumulation of used components in the rotorless vulcanizing apparatus. This rule only applies to a single fault.
The principle of exchange does not apply to the following situations:
The new component was damaged when removed (such as the pump sealing gasket);
Low component prices (such as column lining filter);
Reinstalling the original components carries the risk of damage;
Regularly replaced components.