The UV-2000S cosmetics SPF sun protection index analyzer can quickly measure the diffuse transmittance of sunscreen samples in the 250-450 nm ultraviolet band. Labsphere's Spectralon integrating sphere uses a re optimized scintillation xenon lamp as the light source to provide good sample diffuse illumination effect, thereby reducing integration time. The new diode array spectrometer, combined with advanced fiber optic components, is optimized at the system level to reduce stray light, improve wavelength stability and repeatability between each measurement.
Professional equipment and improved functionality*
The UV-2000S cosmetics SPF sun protection index analyzer adopts new optical, electronic components, and software technologies, integrated into an industry validated system architecture, to obtain accurate ex vivo SPF/UVA protection index analysis indicators for solar protection products, thereby obtaining accurate solar protection label values in development. Driven by the rapid development of the industry, UV-2000S is designed and developed according to recognized in vitro testing methods, such as COLIPA UVA-PF, Boots star Rating, FDA, and several upcoming global standards or methods, in order to simplify product labeling and quickly validate new in vitro testing methods. The launch of UV-2000S is positioned as an industry choice to replace Labsphere UV-1000S products, not only for laboratory in vitro SPF/UVA analysis, but also for basic quality control of products.
A lot of optimization work has been carried out on the UV-2000S cosmetics SPF sun protection index analyzer, including new spectrometers, scintillation xenon lamps, optical coupling fibers, optical head positioning mechanisms, sample positioning platforms, and a new and stable software development platform. The new diode array spectrometer has stable performance and uses a customized concave diffraction optical system to ensure measurement integrity and repeatability. The grating used is a master grating instead of a replicated grating, thereby maximizing performance within the wavelength range. A longer pixel array ensures better pixel wavelength resolution.
The illumination at the integrating sphere is now filtered, which can limit the total exposure of the sample and improve the stray light performance. A higher flicker frequency reduces exposure time, minimizes dark current, and increases dynamic range Zui. The use of sun resistant optical fibers can ensure stable output after a period of use. Longer fibers filter out higher-order modes to provide clean grating illumination and improve stray light performance.
Easy to operate
The built-in report function can generate key information by clicking the button. The report includes necessary information such as date, time, operator name, sample identity, and test parameters. It is easy to access these report information on a computer, and it can also be printed or output in text format for further data processing or analysis.
*Easy to use application software
The UV-2000S cosmetics SPF sunscreen index analyzer application software is based on **Architecture development, software includes modular structure and supports new user interfaces. The software includes the COLIPA method Boots Star Rating、FDA, And new industry or regional methods can be expanded when necessary. The software can facilitate data collection, archiving, retrieval, and report output, and can also record the impact of substrate roughness on UVA-PF.
The UV-2000S application software includes an integrated performance validation process that allows for online validation and revalidation to ensure instrument performance. A set of calibration standards includes a wavelength standard that can capture 6 spectral bands, and each UV transmittance analyzer includes a set of this standard.
Performance characteristics
Sample analysis can obtain results in less than 5 seconds
● Precise sample positioning platform with manual operation and data acquisition function before and after irradiation
The new wavelength standard can capture 6 relevant bands
● Simple and easy-to-use menu based application software
A simple instrument validation process ensures accurate and repetitive measurements
Automatically calculate SPF, UVA/UVB ratio, key wavelength, COLIPA method, and revised Boots Star Rating, FDA
During the testing process, there was no occurrence of ozone
● No sample replacement error, insensitive to fluorescence errors of samples
meet the standard
UVA protection factor: COLIPA Method (2011) standard
UVA protection factor: Revised Boots Star Rating (2008) standard
UVA protection factor: FDA UV1/UVA (2011) standard**
UVA sunscreen method: ISO 24443 standard
Technical parameters
| ★ Model | |
| UV-2000S (including software, sample platform, and validation kit) |
UV-2000S operating software 50 HD6 substrates |
| ★ System properties and performance | |
| Wavelength range: | 250 to 450 nm* |
| Wavelength accuracy: | ±1 nm |
| Broadband (FWHM): | <4 nm |
| Wavelength interval (data interval): | 1 nm |
| ★ Optical Structure | Hemisphere illumination/0 ° viewing angle (d/0) |
Integral sphere material: |
Spectralon® |
| Integral ball opening size: | < 5% |
| Sample exposure area: | 0.79 cm² |
Light source: |
Scintillation xenon lamp |
The amount of ultraviolet radiation per measurement cycle: |
< 0.2 J/cm² |
Sample platform: |
manual |
★ Measurement range | |
| Transmittance rate: | 0 - 100% |
Absorption value: |
0-2.7 A (validated using ISO dual treatment substrate verification method) |
SPF : |
1-50+ |
Scanning time: |
<5 s |
|
Supported measurement standards:
test project |
UVA protection factor: COLIPA Method (2011) standard UVA protection factor: Revised Boots Star Rating (2008) standard UVA protection factor: FDA UV1/UVA (2011) standard** UVA sunscreen methodsISO 24443 standard SPF UVA/UVB Critical wavelength |
| Computer interface: | USB |
Computer requirements: |
1.6 GHz processor, WindowsXP or Windows7 SVGA 800 x 600 256MB RAM, 400MB hard disk space |
| Power supply requirements: | 110 - 120/220 - 240 VAC, 60/50 Hz |
Operating environment: |
0 ℃ -50 ℃, 0% -70% RH (non condensing) |
| Instrument size | |
Dimensions with operating table: |
11H x 22.6D x 12.3W In (27.9H x 56.6D x 31.2W cm) |
Without console size: |
11H x 12.6D x 12.3W in (27.9H 32.0D x 31.2W cm) |
|
★ Optional attachments UV-2000S toolkitHelioScreen HD6 substrate |
AS-02796-000 PP-02097-000 |
software upgrade |
UV-2000S software |
| UV-2000S upgrade package | AS-02942-000*** |
*All system indicators are based on the wavelength range of 290-400nm
**Need an independent solar simulator
***The upgrade package complies with ISO 24443 standard
Industry Applications
SPF index analysis for sunscreen cosmetics