Welcome Customer !

Membership

Help

Luoyang Taiguo Boiler Sales Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

LDR type electric heating boiler

NegotiableUpdate on 09/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The LDR type electric heating boiler is simply a vertical boiler that uses electricity for heating. It refers to a pressure vessel equipment that converts electrical energy into heat energy and heats water to produce steam

Product Details

The LDR type electric heating boiler is simply a vertical boiler that uses electricity for heating. It refers to a pressure vessel equipment that converts electrical energy into heat energy and heats water to produce steam. It mainly consists of a boiler body, an electric control box, and a control system. It operates quietly, noiselessly, and cleanly, especially using electricity (one of the three major clean energy sources in China) for heating, which meets environmental policy requirements and caters to customer psychology.
All electrical components of the LDR electric heating boiler have CE and CCC certification marks, and some accessories also use international brands such as Siemens, greatly improving the quality and service life of the boiler and gaining the trust and recognition of customers.


Performance characteristics:

The heating element of the boiler adopts high-quality stainless steel tubular heating elements with a large heat transfer area.

The product adopts fully automatic intelligent control technology, without the need for dedicated personnel to be on duty.

Can be set to manual or automatic mode,Improved work flexibility and efficiency.

During operation, the boiler does not produce noise or pollution, improving the working environment for workers.

The thermal efficiency is as high as 98%.

The boiler can operate at low load, flexible and versatile, and can operate at a lower load of 30%.

Reasonable design and advanced manufacturing technology make the boiler occupy a small space and facilitate transportation.

Segmented start-up heating enables the boiler to have high start-up rate and minimal impact on the power grid.

The boiler has automatic protection functions such as overcurrent, short circuit, water shortage, water cut-off, overpressure, etc. Once a fault occurs, the system will alarm and take automatic protection measures to ensure the safety of worker operation and the service life of the equipment.

The controller automatically controls, calculates, and tracks pressure, and can automatically start and stop the feedwater pump and electric heating pipe when the load changes, or manually control them.

Technical Specifications:

LDR type electric heating steam boiler
Model rated evaporation capacity
(T/h)
Rated working pressure
(Mpa)
Saturated steam temperature
(℃)
Boiler thermal efficiency
(%)
rated power
(KW)
Design fuel Maximum transportation weight
(KG)
Maximum transport size
(MM)
LDR0.1-0.4 0.1 0.4
0.7
151
171
≥98 72 electric energy 150 φ600x1200
LDR0.2-0.4 0.2 144 430 φ800x1400
LDR0.3-0.7 0.3 216 720 φ1000x1500
LDR0.5-0.7 0.5 360 1100 φ1100x1600
LDR0.7-0.7 0.7 504 1400 φ1250x1750
LDR1.0-0.7 1 720 1600 φ1300x1800
LDR type electric heating atmospheric hot water boiler
Model Rated thermal power
(MW)
Rated working pressure
(Mpa)
Rated outlet/return water temperature
(℃)
Boiler thermal efficiency
(%)
rated power
(KW)
Design fuel Maximum transportation weight
(KG)
Maximum transport size
(MM)
CLDR0.12-95/70 0.12 0 95/70 ≥98 120 electric energy 480 φ900x1450
CLDR0.24-95/70 0.24 240 720 φ1000x1500
CLDR0.35-95/70 0.35 360 1100 φ1100x1600
CLDR0.48-95/70 0.48 480 1400 φ1250x1750
CLDR0.70-95/70 0.7 720 1600 φ1300x1800