Jiangsu 15L high and low temperature circulating water tank
Do you know how to install wet ball gauze in a low-temperature constant temperature bath
Firstly, the editor will introduce the installation steps of the wet bulb gauze in the low-temperature constant temperature bath. First, take out the wet bulb gauze from the packaging bag, and then put it on the wet bulb temperature sensor. Sometimes, due to the large volume of the wet bulb gauze, it is difficult to install it, so it can be disassembled by hand and placed on the sensor.
The next step is to inspect the wet ball gauze. According to regulations, the upper end of the wet ball gauze must be hung on the wet ball sensor, and its lower end should be placed in the water tank of the wet ball gauze, making it easier for it to absorb the moisture in the tank. If the wet ball gauze is installed in other parts of the low-temperature constant temperature bath, it may not be able to fully absorb water, resulting in the illusion that the humidity in the bath cannot be reduced or the humidity control system may malfunction. When conducting a humidity test, it is necessary to check whether the wet bulb gauze is properly hung. If it is hung properly, check if the gauze is moist. If the gauze has been dried or its water absorption effect has deteriorated, please replace or clean the wet ball gauze immediately.
During the experiment, bacteria will grow on the wet ball gauze. If the number of bacteria is too high, the water absorption of the wet ball gauze will deteriorate. Therefore, when contacting the low-temperature constant temperature bath, it is necessary to wash your hands thoroughly and wear gloves to prevent bacteria from being carried onto the wet ball gauze. Because the bath only conducts temperature related environmental tests for a long time, especially when conducting tests above 50 degrees Celsius, please remove the wet bulb gauze. Prevent the wet ball gauze from drying out and affecting the next humidity test.
Installation location:
1. The compressor should be placed in a clean, dust-free environment with no toxic, flammable, or explosive gases in the air and good ventilation (with hot air on the top and cold air on the bottom).
2. The air compressor must be installed indoors (if installed outdoors, a work shed needs to be built to protect various components of the unit), and the lighting brightness should be conducive to operation and maintenance.
If the outdoor environment is poor and there is a lot of dust, a coarse filter should be added to the air inlet of the room to reduce the indoor dust content and facilitate maintenance work.
4. The ambient temperature must be above 5 ℃ to ensure the normal circulation of lubricating oil.
5. There must be a certain amount of space around the air compressor, preferably 1.5 meters away from the wall, as shown in Figure 8, for operators to carry out daily operations, maintenance, and repair work.
6. Heat recovery: Approximately 85% of the output power of the compressor can be recovered in the form of hot air, so this energy should be considered when installing the compressor. The outlet of the hot air should be designed above the top plate of the screw compressor hood for easy pipeline connection.
Main features:
The low-temperature constant temperature bath adopts a fully enclosed imported compressor for refrigeration, and the refrigeration system has multiple protection devices for overheating and overcurrent.
● It has an internal and external circulation function, and the circulation pump can draw out the constant temperature liquid in the tank, establishing a second constant temperature field.
Adopting imported fully automatic PID temperature setting program and imported temperature sensor, the temperature control accuracy is high. Temperature digital display.
The large screen LCD displays both Chinese and English, with clear data and beautiful appearance. The personalized interface makes industrial control no longer monotonous.
The body shell of the low-temperature constant temperature bath adopts mirror anti aging electrostatic spray painting technology, and the inner pot and tabletop are made of stainless steel, which is clean, beautiful and corrosion-resistant.
The cold liquid inside the tank can be introduced externally, and the experimental container outside the cooling machine can also be cooled. Low temperature and constant temperature experiments can be conducted directly inside the tank.
Technical Specifications:
model |
Temperature range (℃) |
temperature fluctuation (℃) |
Digital display resolution (℃) |
Working slot volume (mm)3) |
Groove depth (mm) |
Circulating pump flow rate (L/min) |
Working slot opening (mm)2) |
drainage |
JTGDH-0506 |
-5~100 |
±0.005~±0.02 |
0.001 |
250×200×150 |
150 |
6 |
180×140 |
have |
JTGDH-0510 |
-5~100 |
±0.005~±0.02 |
0.001 |
250×200×200 |
200 |
6 |
180×140 |
have |
JTGDH-0515 |
-5~100 |
±0.005~±0.02 |
0.001 |
280×250×200 |
200 |
6 |
235×160 |
have |
JTGDH-0520 |
-5~100 |
±0.005~±0.02 |
0.001 |
280×250×280 |
280 |
6 |
235×160 |
have |
JTGDH-0530 |
-5~100 |
±0.005~±0.02 |
0.001 |
400×325×230 |
230 |
6 |
310×280 |
have |
JTGDH-1006 |
-10~100 |
±0.005~±0.02 |
0.001 |
250×200×150 |
150 |
6 |
180×140 |
have |
JTGDH-1010 |
-10~100 |
±0.005~±0.02 |
0.001 |
250×200×200 |
200 |
6 |
180×140 |
have |
JTGDH-1015 |
-10~100 |
±0.005~±0.02 |
0.001 |
300×250×200 |
200 |
6 |
235×160 |
have |
JTGDH-1020 |
-10~100 |
±0.005~±0.02 |
0.001 |
280×250×280 |
280 |
6 |
235×160 |
have |
JTGDH-1030 |
-10~100 |
±0.005~±0.02 |
0.001 |
400×325×230 |
230 |
6 |
310×280 |
have |
JTGDH-2006 |
-20~100 |
±0.005~±0.02 |
0.001 |
250×200×150 |
150 |
6 |
180×140 |
have |
JTGDH-2010 |
-20~100 |
±0.005~±0.02 |
0.001 |
250×200×200 |
200 |
6 |
180×140 |
have |
JTGDH-2015 |
-20~100 |
±0.005~±0.02 |
0.001 |
300×250×200 |
200 |
6 |
235×160 |
have |
JTGDH-2030 |
-20~100 |
±0.005~±0.02 |
0.001 |
400×325×230 |
230 |
6 |
310×280 |
have |
JTGDH-3006 |
-30~100 |
±0.005~±0.02 |
0.001 |
250×200×150 |
150 |
6 |
180×140 |
have |
JTGDH-3010 |
-30~100 |
±0.005~±0.02 |
0.001 |
250×200×200 |
200 |
6 |
180×140 |
have |
Jiangsu 15L high and low temperature circulating water tank
In terms of the design of low-temperature constant temperature bath, the route and method of industrial manufacturing products are clearly visible from drawing drawings to establishing models to data. However, there are still data issues between product design stages such as CAD and CAE.
The key to the entire production process is to define the basic data of the product. In the case of a three-dimensional model, the performance, functionality, status, interrelationships, and corresponding modifications of the test chamber are all centered around the product model. So product data is very important. It can help improve low-temperature constant temperature bath products in future production. In the production process, we need to convert the data describing product functions and performance into data used to describe the production and processing process of the product, facilitating maintenance, repair, and other subsequent service status. This is the development direction of our future design models.