JM series multi valve system softener
JM series multi valve system softener
After about ten years of promotion and application of automatic multi way valves in China, the operation control mode of softened water equipment has generally shifted from manual multi way valve control to automatic multi way valve control. However, due to the high integration, small diameter, and complex structure of multi way valves, this control method has certain limitations when applied to systems with large flow rates and complex industrial and mining requirements.
The JM type automatic multi valve water softener is designed to compensate for the shortcomings of multi valve systems. The following table lists the main differences and characteristics between multi valve and multi way valves.
|
|
|
|
|
JM controller The JM multi valve control system consists of a signal distributor and a time/flow program controller, fixed inside the waterproof controller housing. JMA/JMC controllers can be used individually or in combination to achieve automatic control of one or a group of tanks for softening and filtering equipment.
JMA controller There are 16 models of JMA multi valve controllers (501-531), which are not only suitable for fully automatic soft water equipment, but also for various filters, room temperature filter deaerators, and other applicable water treatment equipment. JMA502 controller is selected for downstream regeneration water softener JMA505 controller is selected for the countercurrent regeneration water softener |
Performance characteristics of JMA controller
☆administrator
☆ Ten thousand year calendar display
☆ Display of regeneration steps and decreasing regeneration time
☆ External control signal chain control and step signal output
Four methods: timed start, original transmission (flow or analytical instrument) contact start, on-site temporary start, and on-site forced start
☆ Forced step start (for on-site debugging)
☆ Automatic reset of original position
☆ Regeneration program steps (1-8) and each step time (5-9999 seconds) are optional
Intentional setting
☆ System status signal display (such as system operation or regeneration status feedback)
Signal display)
☆ Power outage protection function: The set parameters are maintained for more than 3 years
The instrument casing is made of engineering plastic, which is dust-proof, corrosion-resistant, and splash proof
Shooting and other functions
Performance characteristics of JMB/JMC flow type controller
☆ Set password
☆ JMB single channel or JMC1-3 multi-channel flowmeter pulse reception
☆ Selection of K value for flowmeter probe (according to the pipeline size for probe installation, please refer to the attached table for reference)
☆ System flow display (0-999T/H) and pre-set batch (1-9999.9T) remaining quantity decreasing display
☆ Accumulated traffic query and reset function
☆ Status display of various systems (working, regeneration, backup, feedback)
☆ Local forced manual start regeneration
☆ Regeneration start signal output time (2-9999 seconds) setting
☆ System working mode:
JMC (C1, D2, D3, E2, E3) offers five options
Nine choices of JMB (C1, C2, C3, C4, C5, D2, D3, D4, D5)
Note: Type C: simultaneous operation and alternate regeneration;
D-type: multiple use and one backup;
E-type: simultaneous operation with separate regeneration;
☆ Auxiliary contact output of regeneration system (controlled by outlet solenoid valve)
☆ Power outage protection function: parameter retention time set after power outage
More than 3 years
The instrument casing is made of engineering plastic, which has functions such as dust prevention, corrosion prevention, and water splash resistance
The instrument adopts wall mounted or bracket mounted installation form
JM Multi Valve Softener Series Configuration Parameter Table
Note: 1) The items marked with an asterisk in the table use a centralized salt system.
2) Equipment working environment:
Pressure 0.2-0.6MPa
Temperature range of 5-50 ℃
Inlet hardness<8mmol/L (if greater than 8mmol/L, please contact the manufacturer for special design)