Intelligent constant temperature and humidity test chamber, high humidity constant temperature chamber

NegotiableUpdate on 01/27
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The intelligent constant temperature and humidity test box has a precise temperature and humidity control system, which can provide various environmental simulation conditions required for industrial research and biotechnology testing. It is suitable for environmental protection, health and epidemic prevention, drug testing, agriculture, animal husbandry, aquaculture and other scientific research, universities, production departments, and is a constant temperature and humidity equipment for water quality analysis and BOD testing, breeding experiments, plant cultivation, etc.
Product Details

Intelligent constant temperature and humidity test chamber, high humidity constant temperature chamberMain features:

1. The outer box is made of cold-rolled steel plate, and the surface is coated with electrostatic spraying technology. The inner box is made of stainless steel insulation layer formed by polyester foam, with good constant temperature effect.

2. The outer door is sealed with a magnetic seal, and the double-layer insulated glass observation door has good sealing performance. There is a lighting lamp inside the box, which is easy to close and can directly observe the condition of the culture in the studio

3. There is a hot air duct in the box body to ensure smooth gas circulation and more balanced temperature inside the box;

4. Microcomputer temperature and humidity integrated controller, with built-in humidification method for good humidity control effect;

5. LCD display controller that displays both parameter settings and actual operating values to meet daily experimental needs.

6. It can set the running time, with a timing range of 0 to 9999 minutes or hours, and can automatically shut down.

7. The over temperature tracking alarm system provides reliable protection for the sample, automatically memorizes the set parameters, and can automatically recover after power interruption.

8. Using high-quality brand fully enclosed compressors and fluorine free green environmentally friendly refrigerants, with high efficiency, low energy consumption, delayed start-up, and automatic high and low pressure protection.

9. The box is equipped with multiple layers of pull-out partitions, and the floor height can be adjusted according to specific needs.

10. The bottom of the box is equipped with four movable double wheel casters to facilitate the movement of the box.

智能恒温恒湿试验箱高湿恒温箱


Intelligent constant temperature and humidity test chamber, high humidity constant temperature chamberTechnical Specifications

1. Model: HWS-250A

2. Power supply: 220V ± 10% 50Hz

3. Temperature control range: 0-60 ℃

4. Temperature resolution: 0.1 ℃

5. Temperature control accuracy: ≤± 0.5 ℃

6. Temperature fluctuation: ≤± 0.5 ℃

7. Temperature uniformity: ≤± 1 ℃

8. Humidity range: 50-95% RH fluctuation range 5-8% RH

9. Humidity control: LCD built-in

10. Inner container size: 500 × 500 × 1000mm

11. Suitable operating environment temperature range: -5-28 degrees/humidity 20% -90%

Installation and placement precautions
Ground requirements: After the constant temperature and humidity incubator is placed on the ground, the ground should be flat and placed steadily to prevent vibration and noise.
Space requirements: It should be placed in a cool, dry, well ventilated place away from heat sources and direct sunlight. To ensure effective heat dissipation of the condenser, the distance between the condenser and the wall should be greater than 100mm, there should be a 50mm gap on the side of the box, and there should be at least 300mm of space at the top of the box.
Grounding requirements: The box shell should be properly grounded to prevent electrical leakage; The casing should be reliably grounded.
Precautions during use
Before operation
Internal and external inspection: Conduct internal and external inspections before use. If there are any items stored by others inside the box, take them out and put them away; Check whether the test switch, temperature control handle, etc. are flexible and easy to use; Open the air vent and insert the thermometer; Pay attention to whether the power supply matches the nominal voltage on the nameplate.
Avoid hazardous environments: To prevent machine malfunctions, please provide a power supply within the rated voltage range; This product is non explosion proof and should not be used in environments with flammable or explosive gases; Do not turn on the power until installation and wiring are complete.
In progress
Load placement: During normal operation, the placement of loads inside the box should not affect air circulation to ensure uniform temperature inside the box; Avoid overloading and do not put too many samples into the incubator to avoid affecting the uniformity and stability of temperature and humidity.
Switch box door: Try not to open the test box door during instrument operation. Opening it at high temperatures may cause burns to the operator, and opening it at low temperatures may have adverse effects on the staff; Wait until the temperature inside the box is not very high before opening the door to prevent the glass door from breaking due to sudden cooling.
Temperature regulation: If the heating indicator red light is not on, turn the temperature control knob clockwise until the red light is on; When the temperature inside the box approaches the desired temperature, perform the corresponding heating wire switch operation and adjust the temperature control knob; The scale indicated by the temperature control knob is not the temperature inside the box. After each constant temperature, the constant temperature and the scale indicated by the knob can be recorded accordingly for future reference.
Prevent condensation: reduce condensation on the surface during module testing; There shall be no condensed water droplets on the test piece at the top of the cabinet; During the experiment, condensed water should not condense on the vibration table.