Sanwei Science has launched high flow and high viscosity metering pumps, high viscosity feed pumps, and high viscosity constant flow pumps. The products are high-precision and pulse free, with a minimum flow increment of 0.01ml/min, and can transport liquid viscosity ranging from 0-1000 centipoise (cP). They can transport low viscosity organic solvents such as methanol and ethyl acetate, as well as high viscosity chemical materials such as concentrated sulfuric acid, silicone oil, photoresist, etc. They are widely used in new material process equipment, plastic modification process equipment, chemical feed and catalyst feed, chemical feed and reactant addition in microchannel reactors, chemical reaction devices, catalytic evaluation devices, supercritical fluid transport, foaming extrusion processes, new energy research, catalytic refining kettle reactions and other devices. Supporting facilities.
The high viscosity pump series includes: stainless steel pump head high viscosity pump, PTFE pump head high viscosity pump, Hastelloy pump head high viscosity pump
The flow viscosity specifications of the high viscosity pump series include: 0-10ml 1200 cP; 0-100ml 1000 cP; 0-300ml 700 cP; 0-600ml 400 cP; 0-1000ml 200 cP; 0-2000ml, 100 cP and other specifications

Characteristics of high viscosity and high-pressure metering pump products:
Accurate delivery of hardware functions
Multi point flow calibration: achieving high accuracy and high repeatability in fluid transport across the entire range
Flow pulse suppression: Cam curve compensation and flow pulse electronic suppression effectively control pressure pulses
Pressure setting correction: protection pressure setting of the flow path, zero point value correction to eliminate environmental interference
Piston cleaning function: After cleaning the plunger, reduce the wear of the sealing ring and extend the service life of the pump
Overpressure start stop mode: Multiple overpressure modes, automatic, manual, and low-pressure restart modes after overpressure
Timing control mode: The timing control of liquid delivery can be effectively achieved through buttons or software
Client traffic calibration: supports client single point traffic calibration and full flow segment linear traffic calibration
Integration of communication function system
Multiple communication modes: one-to-one control, one to many control, many to many control
Multiple communication ports: USB, RS232, RS485, WLAN, CAN, Ethernet, wired/wireless network
Multiple communication protocols: Modbus RTU/TCP, Profinet, CanOpen, EtherNet/IP, etc
Support system integration: integration into SCADA/DCS/PLC control systems and configuration applications
Analog digital control: analog input control, switch start stop control
Software function extension application
Transport unit switching: Switch the flow rate unit and select to transport by volume or weight
Flow rate variation control: constant, linear, gradient flow rate delivery, can be derived in any combination
Real time display of readings: real-time drawing of flow rate and pressure curves, display of program running progress bar
Data Record Export: Real time recording of flow and pressure data, exported in tabular and graphical form
Method save and call: Save and call multiple flow rate programs, control convenient switching between methods
Calibration and maintenance function: Customize flow calibration to meet specific operating conditions and restore factory parameters
Technical parameters of high viscosity and high-pressure metering pump:
| serial number | Product Model | SV3015 | SV6015 | SV1110 |
| 1 | Infusion method | Dual plunger series mode, floating plunger design, 316L pump head | ||
| 2 | Viscosity range | 0-700cP | 0-400cP | 0-200cP |
| 3 | flow range | 0.01-300.00ml/min | 0.01-600.00ml/min | 0.1-1000.0ml/min |
| 4 | increment | 0.01ml/min | 0.1ml/min | |
| 5 | Traffic accuracy | ± 0.5% | ||
| 6 | Traffic repeatability | ≤ 0.5% | ||
| 7 | pressure range | ≤ 15Mpa | ≤ 10Mpa | |
| 8 | pressure pulsation | ≤ 0.2Mpa | ≤ 0.5Mpa | |
| 9 | Flow path material | 316L stainless steel PTFE、PEEK、 ceramic | ||
| 10 | Pipeline connection | 1/8 'standard pipeline connection | ||
| 11 | Display parameters | 256 * 64 dot LCD display, self luminous display screen | ||
| 12 | Communication function | USB,RS232,RS485; Modbus protocol; Switching and analog input | ||
| 13 | upper computer software | SanoFlu Fluid Control Management System | ||
| 14 | power supply | 100~240VAC,50/60Hz | ||
| 15 | size | 550×420×222 mm3 | ||