- Phone
-
Address
Room 4032, Building 1, No. 10 Hongfu Courtyard, Beiqijia Town, Changping District, Beijing
Beijing Gredeman Instrument Equipment Co., Ltd
Room 4032, Building 1, No. 10 Hongfu Courtyard, Beiqijia Town, Changping District, Beijing
The GT50R frozen tissue grinder is a professional pre-processing and crushing system for biological samples that is fast, efficient, and high-throughput. It can perform wet grinding, dry grinding, and low-temperature grinding, and has the functions of tissue homogenization, grinding, cell crushing, homogenization, and material dispersion. Low temperature grinding of biological samples can effectively inhibit nucleic acid degradation and preserve protein activity. By using different reagents, various substances can be crushed and extracted, and cells can be quickly crushed. Samples from any source (including soil, plant and animal tissues/organs, bacteria, yeast, fungi, spores, paleontological specimens, etc.) can be ground and crushed to facilitate the extraction and purification of original DNA, RNA, and proteins.
Product Application
Application areas: Molecular marker assisted breeding, genomics, systems biology and molecular evolution, transgenic research, and other biochemical research fields for plant tissue nucleic acid extraction.
Typical samples: roots, stems, leaves, flowers, fruits, seeds, and certain animal tissues of plants: particularly suitable for extracting nucleic acids, proteins, and other components from plant tissues. In addition, it can also crush yeast, animal cells, bacterial cells, etc. to extract their components.
Rapid preparation of multiple samples using PCR (polymerase chain reaction) and rapid lysis of tissue homogenate for nucleic acid extraction, RNA/DNA extraction, and protein extraction
Cracking of yeast and bacterial cells
Pesticide/Insecticide Analysis (Sample Processing of Food Pesticide Residues or Toxic Substances in LC/MS Testing)
QuEChERS method (pesticide, antibiotic, drug extraction)
Extraction of Medicinal Active Ingredient APIs
Food safety (contamination, adulteration, food traceability)
biofuel
Performance advantages
Place the sample into a centrifuge tube and use vertical shaking mode to allow the grinding ball to collide and rub against the sample, along with a formula reagent that breaks down cell walls and membranes while protecting nucleic acid proteins, to achieve the extraction of target DNA, RNA, and proteins. The research results have good repeatability and there is no cross contamination between samples. Each sample can be quickly and efficiently ground in only 1-2 minutes.

Performance advantages
Adopting vertical grinding design
Multiple sizes and materials of grinding balls are available for selection
Desktop design, symmetrical design of the motor and refrigeration compressor horizontally on both sides, saving storage space
Compressor refrigeration, with low-temperature freezing function, refrigeration value>-50 ℃, temperature control accuracy ≤± 0.5 ℃
Low speed crushing function effectively ensures sample yield, especially suitable for genome preparation
Controllable electric control equipment for opening and closing doors. After grinding is completed, the equipment can intelligently start without manual operation
The instrument has program control and parameter storage functions, and can store more than 20 sets of experimental data. Historical experimental data can be recorded and exported at any time
The application of new brushless motors and the direct transmission of motors make instrument maintenance very convenient
Both centrifuge tubes and cryovials can be used, with centrifuge tubes ranging from 0.2ml to 50ml available, as well as single sample and single tube operationsmutualIsolate and eliminate cross contamination
The fixed method adopts a simple clamping device, which can reduce the risk of crushing the grinding tube. Under high-intensity grinding work, the sample tube can also be intact and undamaged
Adopting the original pulse motor drive system and good shock absorption principle, it has stable performance, long-lasting durability, and can maintain low noise and smooth operation during high-speed grinding
Dual electronic lock protection device, one key electric door opening, unable to start the instrument when the host is not closed
There are various adapter specifications to choose from, and they are universal and can be adapted to multiple similar instruments
The time taken to accelerate to maximum speed is ≤ 2 seconds, and the time taken for maximum speed to drop to zero is ≤ 2 seconds
Control Panel
The device adopts a 5-inch LED touch screen design, which is easy to operate
Multiple language options to meet diverse user needs
Vibration speed, time and other parameters can be set on the screen, which is simple, convenient and fast
Main technical parameters
| Injection size | <10 millimeters |
| Sample size | <5 microns (depending on sample properties) |
| rotation speed | 1300-1800 revolutions per minute |
| Time Settings | 00:01-99:59 (minutes/second) |
| temperature | -50℃ |
| Fixture travel | 32 milliliters |
| Frequency setting | 22-30Hz |
| Standard | CE |
| Overall Dimensions | 700 * 555 * 600 millimeters |
| weight | 75 kilograms |