E-mail
739915789@qq.com
-
Phone
19941565709
-
Address
No. 788 Shuangying Road, Wuyi Industrial Park, Nanqiao District, Chuzhou City, Anhui Province
Anhui Hilbert Environmental Testing Instrument Co., Ltd
739915789@qq.com
19941565709
No. 788 Shuangying Road, Wuyi Industrial Park, Nanqiao District, Chuzhou City, Anhui Province
High and low temperature damp heat test chamberTechnical parameters and performance indicators
| High and low temperature humid heat chamber model | GDS-50 | GDS-100 | GDS-150 | GDS-225 | |||||
| Studio size (mm) | 300×400×450 | 400×450×550 | 500×600×500 | 500×600×750 | |||||
| High and low temperature humid heat chamber model | GDS-408 | GDS-800 | GDS-010 | GDS-015 | |||||
| Studio size (mm) | 600×800×850 | 800×1000×1000 | 1000×1000×1000 | 1000×1500×1000 | |||||
| Operation mode | Fixed value operation, program operation | ||||||||
| skill technique ginseng number | temperature upper limit | +100℃/+150℃ /+200℃ | |||||||
| lower temperature limit | 0℃、 -10℃、- 20℃、- 30℃、 -40℃、 -50℃、 -60℃、- 70℃、- 80℃ | ||||||||
| temperature fluctuation | ±0.5 ℃ | ||||||||
| Temperature Uniformity | ≤2.0 ℃ | ||||||||
| temperature deviation | ±2 ℃ | ||||||||
| humidity range | 20~98%RH | ||||||||
| Humidity deviation | + 2/- 3% RH | ||||||||
| warm-up time | 40min( 20℃~ 100℃) | ||||||||
| cooling time | 25min( 20℃~ 0℃)、 40min( 20℃~- 20℃) 60min( 20℃~- 40℃)、 80min( 20℃~- 70℃) | ||||||||
| Temperature and humidity controller | Imported temperature and humidity controller | ||||||||
| temperature sensor | Pt100 platinum resistor | ||||||||
| humidity sensor | Pt100 platinum resistance dry wet bulb | ||||||||
| manufacture cold be unify | refrigeration unit | Imported fully enclosed French Taikang compressor unit (environmentally friendly) | |||||||
| Cooling method | Single stage compression refrigeration, binary cascade compression refrigeration | ||||||||
| cooling method | Air cooling/water cooling | ||||||||
| heater | Nickel chromium alloy electric heater | ||||||||
| Humidification method | Boiler type evaporation | ||||||||
| humidifier | Stainless steel heating tube | ||||||||
| Dehumidification method | Low temperature dehumidification | ||||||||
| circulating fan | axial flow fan | ||||||||
| Security protection measures | Overtemperature, overload, overpressure, oil pressure Protection against leakage, water interruption, short circuit, power phase loss, and phase error | ||||||||
| material material | housing material | Cold rolled steel plate electrostatic spraying | |||||||
| Inner wall material | SUS304 stainless steel plate | ||||||||
| thermal insulation material | Ultra fine glass wool | ||||||||
| Standard Configuration | One test hole of size 50, two sets of test sample shelves, lighting fixtures, and insulated glass observation windows coated with electric heating film | ||||||||
| Optional accessories | Communication interface, remote monitoring computer and software | ||||||||
| power supply | 380V±10%, 50Hz, 3P+ N+ G | ||||||||
| product standard | GB10586: Technical Conditions for Damp Heat Test Chamber GB10589: Technical Conditions for Low Temperature Test Chamber | ||||||||