- Phone
-
Address
Room 1501, Caoyang Business Building, 889 Zhongjiang Road, Putuo District, Shanghai
Shanghai Weitelui Industrial Development Co., Ltd
Room 1501, Caoyang Business Building, 889 Zhongjiang Road, Putuo District, Shanghai
German VSE flowmeter in stock VSI2/10 S07V32
AllThe flow meter is from GermanyAllThe high-precision volumetric flow measurement instrument developed by the company,Vsi2 / 10 s07v32The model is a classic model in the series, which uses gear meshing principle to achieve flow measurement. It has the characteristics of high measurement accuracy, strong stability, and wide range of applicable media. It is widely used in industrial process control, hydraulic systems, engineering machinery and other fields
parameter category |
specific parameters |
model |
Vsi2 / 10 s07v32 |
Nominal Diameter |
10 mm(According to the model)“10”Identification) |
flow range |
0.1 - 20 L/min(Typical value, depending on the viscosity of the medium) |
measurement accuracy |
±0.1% FS(Full scale accuracy, under standard conditions) |
repetitiveness |
±0.05%(Short term repeatability) |
Medium temperature range |
-20℃ - +120℃(Standard configuration) |
Range of work pressure |
maximum350 bar(Continuous work pressure) |
Viscosity adaptation range |
1 - 10000 cSt(High viscosity media require special configuration) |
output signal |
Pulse signal(NPN/PNPOpen collector), optional4-20mAanalog signal |
power supply voltage |
10 - 30 VDC(Standard electrical interface) |
response time |
< 1 ms(Pulse signal output) |
material |
Shell: Aluminum alloy/stainless steel; Gear: hardened steel/Ceramics (optional) |
Functional scope
Real time monitoring of the volumetric flow rate of liquid media through flow measurement, supporting instantaneous and cumulative flow measurement
Signal output is achieved through pulses or analog signalsPLCTheDCSWait for the control system to interface and achieve data acquisition and closed-loop control
Media compatibility is applicable to mineral oil, hydraulic oil, lubricating oil, and water-Ethylene glycol solution, diesel and other industrial fluids
Adapt to the environment and have good resistance to vibration(10-2000Hz,10gAcceleration and impact resistance, suitable for harsh industrial environments
Temperature and pressure characteristics
temperature effect
at-20℃ - +120℃Within the range, the measurement accuracy of the instrument is less affected by temperature, and every temperature change10℃Accuracy deviation≤±O.02% FS
When the temperature of the medium exceeds120℃When selecting, high-temperature sealing materials (such as fluororubber) should be used, which can be expanded up to150℃
pressure characteristics
The impact of work pressure on measurement accuracy can be ignored,350barThe pressure resistant design makes it suitable for high-pressure hydraulic systems
When the pressure fluctuates, the instrument maintains measurement stability through the tight meshing of the internal gear structure, resulting in pressure loss≤0.5bar(At maximum flow)
Key factors during use
Media requirements
The medium needs to be cleaned to avoid solid particles (installation recommended)100Filter above the target to prevent gear jamming
For high viscosity media(>1000 cSt)To ensure measurement accuracy, it is necessary to reduce the maximum flow rate
To avoid cavitation, sufficient back pressure should be ensured on the inlet side (usually≥1bar)
Flow accuracy guarantee
at5% - 100%Within the range, maintain accuracy±0.1% FS; Below5%When measuring range, the accuracy drops to±0.2% FS
Suggest using actual flow control within the range20% - 80%To achieve the best measurement results
The relationship between viscosity and flow rate
An increase in viscosity will lead to a decrease in the upper limit of the flow rate. The viscosity is1000 cStAt that time, the maximum flow rate was approximately5 L/min
The viscosity is10 cStAt this time, the maximum flow rate can reach20 L/minWhen selecting, the flow range should be checked based on the actual viscosity of the medium
The principle of high-precision volumetric measurement ensures stable accuracy over a wide viscosity range, which is superior to flow meters such as turbines and electromagnetic meters
High pressure tolerance350barThe working pressure meets the requirements of high-pressure hydraulic systems and is suitable for scenarios such as construction machinery and injection molding machines
quick response1msThe response time can capture transient changes in flow and support dynamic process control
Long life design with hardened steel gears and precision bearings, no contact wear, average no working time(MTBF)>50000hour
Flexible installation supports horizontal and vertical installation, and the inlet and outlet directions can be adjusted according to the pipeline
Application Fields and Scenarios
application field |
typical scenario |
hydraulic system |
Hydraulic oil flow monitoring for injection molding machines and die-casting machines to achieve closed-loop control |
construction machinery |
Hydraulic circuit flow measurement for excavators and cranes to prevent overload |
Industrial Lubrication |
Lubricating oil flow monitoring for gearboxes and bearings to ensure adequate lubrication |
petrochemical |
Filling, transportation and metering of diesel, lubricating oil and other oil products |
automobile manufacturing |
Fuel flow measurement and power system performance evaluation on engine test bench |
Installation method
pipeline connection
Using threaded connections (standard)G1/2'orNPT1/2'Interface), sealing gaskets should be used during installation to prevent leakage
The import and export directions must be consistent with the arrow markings on the instrument housing, and reverse installation is strictly prohibited
Upstream straight pipe section requirements: There are no strict straight pipe section requirements, it is recommended to retain them upstream5A straight pipe section with a length equal to the diameter of the pipe
electrical connection
throughM12Circular connectors or cable leads are used to connect power and signal lines, ensuring correct polarity
Shielded cables and grounding resistors are required for pulse signals≤1ΩReduce electromagnetic interference
Installation location
Prioritize installation on the low-pressure side of the system (return oil pipeline) to avoid high-pressure impact; If installed on the high-pressure side, it is necessary to ensure that the pressure does not exceed the rated value
When installed vertically, it is recommended that the medium flow from bottom to top to avoid the accumulation of bubbles
Precautions
Media filtration must be installed with a filter upstream of the instrument, ensuring high filtration accuracy≤25μmTo prevent impurities from damaging the gears
Avoid running for a long time without any medium during idle operation to prevent gear wear caused by dry friction
The maintenance cycle is to check the aging condition of the sealing components once a year3Annual precision calibration (requires professional organization)
Environmental protection: Avoid direct sunlight and corrosive gases. Outdoor installations require protective enclosures
If the output signal is abnormal, first check whether the power supply, wiring, and filter are blocked, and then check whether the gear is stuck
Vsi2 / 10 s07v32Flow meters are particularly suitable for industrial scenarios with strict flow measurement requirements due to their high precision, high pressure resistance, and wide viscosity adaptability. It is recommended to prioritize the use of closed-loop control in hydraulic systems, high-pressure fluid metering, and high viscosity medium monitoring. Attention should be paid to the cleanliness of the medium and installation direction when using it, in order to fully utilize its performance advantages and reduce maintenance costs
VSI0.2/16 GPO 12V-32W15/4
Vsi2 / 10 s07v32
Vsi0.04 / 1 EPO 12v-42r11 / 4
German VSE flowmeter in stock VSI2/10 S07V32
KRACHT Clark from Germany provides on-site selection and technical support for flow meters and indicators, and has competitive purchasing prices for gear pumps, valves, and spare parts
VSE Germany (flowmeter provides project selection and technical support)
In addition, there are many brands that also have advantages:
Beinlich Bailey pump (optional)
RICKMEIER pump (optional)
MTS sensor
TEMPOSONICS sensor
MEISTER flow switch
KOBOLD flowmeter, temperature switch
ATOS hydraulic solenoid valve, pump, pressure relay
WEBTEC flowmeter, flow indicator
HYDAC Hedec filters, filter cartridges, sensors
P+F Beckhoff sensor, safety barrier
HAWE hydraulic pump, hydraulic valve
VESTA Vesta cylinder, solenoid valve