Welcome Customer !

Membership

Help

Shanghai Weitelui Industrial Development Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Weitelui Industrial Development Co., Ltd

  • E-mail

  • Phone

  • Address

    Room 1501, Caoyang Business Building, 889 Zhongjiang Road, Putuo District, Shanghai

Contact Now

German VSE flowmeter VS4 GPO 12V-32N11/6 in stock

NegotiableUpdate on 05/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

German VSE flowmeter VS4 GPO 12V-32N11/6 in stock $r $n Shanghai Weite Rui Industrial Development Co., Ltd. has excellent service and a 22 year credit guarantee $r $n Find the right supplier Shanghai Weite Rui has guaranteed after-sales service and peace of mind

Product Details

German VSE flowmeter VS4 GPO 12V-32N11/6 in stock

VSE VS4 GPO 12V-32N11/6It's GermanyAllA high-precision volumetric flowmeter produced by the company, using gear measurement principle, is suitable for the field of industrial fluid measurement. This model integrates12VThe electronic signal processing unit for power supply has pulse output function and can monitor the medium flow rate in real time. It is widely used in hydraulic systems, lubrication equipment, and precision fluid control scenarios

parameter item

numerical value/description

model

VS4 GPO 12V-32N11/6

Measuring principle

Volumetric (gear type)

power supply voltage

12V DC±10%

signal output

Pulse signal(NPN/PNPOptional)

interface type

GPOThreaded connection (specific dimensions need to refer to the sample)

flow range

Nominal flow rate:4 L/minUnder standard operating conditions, based on viscosity20 cStMedia)
Measuring range:0.1 - 10 L/min(can be adjusted according to the viscosity of the medium)
Repetitive error:≤±O.1%(Full scale)
Linearity error:≤±O.5% FS(Under standard conditions)

Media compatibility

Applicable medium types: low to medium viscosity fluids such as mineral oil, hydraulic oil, lubricating oil, synthetic oil, etc
Viscosity range:5 - 1000 cSt(Viscosity exceeds200 cStReduced usage is required)
Medium temperature range:-20℃ - +100℃(Short term tolerable)120℃

pressure parameter

Work pressure: maximum320 bar(Continuous work)
Blasting pressure:≥640 bar(Safety factor)2:1
Pressure loss:≤1.5 bar(Under nominal flow)

environmental parameters

Operating Temperature-40℃ - +85℃(Electronic components)
Protection level:IP65(Depending on the installation method, it may be upgraded toIP67
vibrationresistance10 - 2000 Hz10 gIEC 60068-2-6

Features

high-precision measurement

Adopting a dual gear meshing structure, volume measurement is achieved by counting the number of gear rotations, ensuring maintenance within a wide flow range±0.5%Linear accuracy

Especially suitable for closed-loop systems that require precise flow control

Wide viscosity adaptability

Built in bearing design optimization, can be used in5 - 1000 cStStable operation within viscosity range, no need for frequent calibration

For high viscosity media such as gear oil, it is recommended to reduce the maximum flow rate to ensure measurement accuracy

Integrated electronic module

12VThe signal processing unit powered by DC directly outputs pulse signals, which can be combined withPLCSeamless integration of flow integrators or data acquisition systems to simplify system integration

Partial model support4-20mAAnalog output (configuration needs to be confirmed)

High pressure tolerance

The metal shell (usually made of aluminum alloy or stainless steel) is designed to withstand320 barWork pressure, suitable for high-pressure hydraulic systems such as injection molding machines, construction machinery, and other scenarios

compact structure

Compact in size and lightweight (approximately)0.5 kg)Suitable for situations where installation space is limited

GPOThreaded interface supports quick installation, reducing the complexity of pipeline connections

application field

Industrial hydraulic system

Used to monitor the output flow rate of hydraulic pumps and actuator components (oil cylinders)/Real time flow of motors to achieve system efficiency analysis and fault diagnosis
Flow monitoring of hydraulic circuit in injection molding machine
Dynamic flow measurement of machine tool hydraulic system

lubrication system

Accurately measure the supply of lubricating oil to ensure the lubrication effect of equipment bearings, gears and other components
Lubrication flow monitoring of wind turbine gearbox
Centralized lubrication system for automated production line

Fluid Transport and Measurement

As a measuring unit in the transportation of low viscosity media
Flow measurement of fuel delivery system
Quantitative control of fine chemical fluids such as ink and coatings

Testing and Development

Used for studying fluid dynamics characteristics in laboratory environments, or as calibration equipment to verify the performance of other flow meters

Installation method

The flow direction requires strict installation according to the arrow indication on the shell. Reverse installation may cause measurement failure or damage to the internal gears
It is recommended to install the pipeline connection before and after the flowmeter10A straight pipe section with a length equal to the diameter of the pipe, reducing the impact of turbulence
The installation position should avoid direct installation at the pump outlet (buffer device needs to be installed), and priority should be given to horizontal installation (gear shaft horizontal) to ensure bearing lubrication

Check before use

Confirmation of medium compatibility: The viscosity, temperature, corrosiveness of the medium match the material of the flowmeter
Stable use of power supply voltage12VDC power supply to avoid signal abnormalities caused by voltage fluctuations
Pre rinse the pipeline before installation to remove impurities (it is recommended to install a filter with high accuracy)≥80μm

routine maintenance

Regularly check every6Check the interface sealing and signal output stability every month
The cleaning cycle is determined by the cleanliness of the medium1-2Disassemble and clean the internal gears annually
It is recommended to perform flow calibration once a year to ensure that the accuracy meets the requirements

Fault handling

No signal output. Check if the power supply and wiring are normal, and if the gears are stuck
Check if the viscosity of the medium exceeds the range or if there is any leakage in the pipeline due to excessive measurement error
Abnormal pressure loss may be caused by clogged filter screens, which need to be cleaned in a timely manner

High reliability German manufacturing process, average working time(MTBF)Exceeding50000hour
Strong adaptability across a wide range of pressure, temperature, and viscosity, meeting the needs of multiple application scenarios
Compared to similar imported brands, it has better cost-effectiveness and higher precision/Price ratio
Easy to integrate standardized signal output and support mainstream industrial control systems
Low maintenance cost, simple structure, easy replacement of spare parts, no need for frequent maintenance

VSE VS4 GPO 12V-32N11/6Flow meters have become an ideal choice in the field of industrial fluid measurement due to their high precision, high pressure tolerance, and wide medium adaptability. Its compact design and convenient signal output make it easy to integrate into various automation systems, especially recommended for hydraulic, lubrication, and fine fluid control scenarios. During installation and use, attention should be paid to medium compatibility, pipeline layout, and regular maintenance to ensure long-term stable operation.

VS0.02 GPO 12V-32N11/4

VS0.1 GPO 12V-12N11/3

VS0.4 GPO 12V-32N11/4

VS1 GPO 12V-32N11/4

VS2 GPO 12V-32N11/4

VS4 GPO 12V-32N11/6

德国VSE流量计VS4 GPO 12V-32N11/6现货

German VSE flowmeter VS4 GPO 12V-32N11/6 in stock

Beinlich Bailey pump (optional)

RICKMEIER pump (optional)

MTS sensor

MEISTER flow switch

KOBOLD flowmeter, temperature switch

ATOS hydraulic solenoid valve, pump, pressure relay

EATON/VICKERS pumps and valves

REXROTH Rexroth hydraulic valve, vane pump

HYDAC Hedec filters, filter cartridges, sensors

KRACHT Clark, Germany

VSE Germany