- Phone
-
Address
Room 1501, Caoyang Business Building, 889 Zhongjiang Road, Putuo District, Shanghai
Shanghai Weitelui Industrial Development Co., Ltd
Room 1501, Caoyang Business Building, 889 Zhongjiang Road, Putuo District, Shanghai
German VSE flowmeter VS4 GPO 12V-32N11/6 in stock
VSE VS4 GPO 12V-32N11/6It's GermanyAllA high-precision volumetric flowmeter produced by the company, using gear measurement principle, is suitable for the field of industrial fluid measurement. This model integrates12VThe electronic signal processing unit for power supply has pulse output function and can monitor the medium flow rate in real time. It is widely used in hydraulic systems, lubrication equipment, and precision fluid control scenarios
parameter item |
numerical value/description |
model |
VS4 GPO 12V-32N11/6 |
Measuring principle |
Volumetric (gear type) |
power supply voltage |
12V DC(±10%) |
signal output |
Pulse signal(NPN/PNPOptional) |
interface type |
GPOThreaded connection (specific dimensions need to refer to the sample) |
flow range
Nominal flow rate:4 L/minUnder standard operating conditions, based on viscosity20 cStMedia)
Measuring range:0.1 - 10 L/min(can be adjusted according to the viscosity of the medium)
Repetitive error:≤±O.1%(Full scale)
Linearity error:≤±O.5% FS(Under standard conditions)
Media compatibility
Applicable medium types: low to medium viscosity fluids such as mineral oil, hydraulic oil, lubricating oil, synthetic oil, etc
Viscosity range:5 - 1000 cSt(Viscosity exceeds200 cStReduced usage is required)
Medium temperature range:-20℃ - +100℃(Short term tolerable)120℃)
pressure parameter
Work pressure: maximum320 bar(Continuous work)
Blasting pressure:≥640 bar(Safety factor)2:1)
Pressure loss:≤1.5 bar(Under nominal flow)
environmental parameters
Operating Temperature-40℃ - +85℃(Electronic components)
Protection level:IP65(Depending on the installation method, it may be upgraded toIP67)
vibrationresistance:10 - 2000 Hz,10 g(IEC 60068-2-6)
Features
high-precision measurement
Adopting a dual gear meshing structure, volume measurement is achieved by counting the number of gear rotations, ensuring maintenance within a wide flow range±0.5%Linear accuracy
Especially suitable for closed-loop systems that require precise flow control
Wide viscosity adaptability
Built in bearing design optimization, can be used in5 - 1000 cStStable operation within viscosity range, no need for frequent calibration
For high viscosity media such as gear oil, it is recommended to reduce the maximum flow rate to ensure measurement accuracy
Integrated electronic module
12VThe signal processing unit powered by DC directly outputs pulse signals, which can be combined withPLCSeamless integration of flow integrators or data acquisition systems to simplify system integration
Partial model support4-20mAAnalog output (configuration needs to be confirmed)
High pressure tolerance
The metal shell (usually made of aluminum alloy or stainless steel) is designed to withstand320 barWork pressure, suitable for high-pressure hydraulic systems such as injection molding machines, construction machinery, and other scenarios
compact structure
Compact in size and lightweight (approximately)0.5 kg)Suitable for situations where installation space is limited
GPOThreaded interface supports quick installation, reducing the complexity of pipeline connections
application field
Industrial hydraulic system
Used to monitor the output flow rate of hydraulic pumps and actuator components (oil cylinders)/Real time flow of motors to achieve system efficiency analysis and fault diagnosis
Flow monitoring of hydraulic circuit in injection molding machine
Dynamic flow measurement of machine tool hydraulic system
lubrication system
Accurately measure the supply of lubricating oil to ensure the lubrication effect of equipment bearings, gears and other components
Lubrication flow monitoring of wind turbine gearbox
Centralized lubrication system for automated production line
Fluid Transport and Measurement
As a measuring unit in the transportation of low viscosity media
Flow measurement of fuel delivery system
Quantitative control of fine chemical fluids such as ink and coatings
Testing and Development
Used for studying fluid dynamics characteristics in laboratory environments, or as calibration equipment to verify the performance of other flow meters
Installation method
The flow direction requires strict installation according to the arrow indication on the shell. Reverse installation may cause measurement failure or damage to the internal gears
It is recommended to install the pipeline connection before and after the flowmeter10A straight pipe section with a length equal to the diameter of the pipe, reducing the impact of turbulence
The installation position should avoid direct installation at the pump outlet (buffer device needs to be installed), and priority should be given to horizontal installation (gear shaft horizontal) to ensure bearing lubrication
Check before use
Confirmation of medium compatibility: The viscosity, temperature, corrosiveness of the medium match the material of the flowmeter
Stable use of power supply voltage12VDC power supply to avoid signal abnormalities caused by voltage fluctuations
Pre rinse the pipeline before installation to remove impurities (it is recommended to install a filter with high accuracy)≥80μm)
routine maintenance
Regularly check every6Check the interface sealing and signal output stability every month
The cleaning cycle is determined by the cleanliness of the medium1-2Disassemble and clean the internal gears annually
It is recommended to perform flow calibration once a year to ensure that the accuracy meets the requirements
Fault handling
No signal output. Check if the power supply and wiring are normal, and if the gears are stuck
Check if the viscosity of the medium exceeds the range or if there is any leakage in the pipeline due to excessive measurement error
Abnormal pressure loss may be caused by clogged filter screens, which need to be cleaned in a timely manner
High reliability German manufacturing process, average working time(MTBF)Exceeding50000hour
Strong adaptability across a wide range of pressure, temperature, and viscosity, meeting the needs of multiple application scenarios
Compared to similar imported brands, it has better cost-effectiveness and higher precision/Price ratio
Easy to integrate standardized signal output and support mainstream industrial control systems
Low maintenance cost, simple structure, easy replacement of spare parts, no need for frequent maintenance
VSE VS4 GPO 12V-32N11/6Flow meters have become an ideal choice in the field of industrial fluid measurement due to their high precision, high pressure tolerance, and wide medium adaptability. Its compact design and convenient signal output make it easy to integrate into various automation systems, especially recommended for hydraulic, lubrication, and fine fluid control scenarios. During installation and use, attention should be paid to medium compatibility, pipeline layout, and regular maintenance to ensure long-term stable operation.
VS0.02 GPO 12V-32N11/4
VS0.1 GPO 12V-12N11/3
VS0.4 GPO 12V-32N11/4
VS1 GPO 12V-32N11/4
VS2 GPO 12V-32N11/4
VS4 GPO 12V-32N11/6

German VSE flowmeter VS4 GPO 12V-32N11/6 in stock
Beinlich Bailey pump (optional)
RICKMEIER pump (optional)
MTS sensor
MEISTER flow switch
KOBOLD flowmeter, temperature switch
ATOS hydraulic solenoid valve, pump, pressure relay
EATON/VICKERS pumps and valves
REXROTH Rexroth hydraulic valve, vane pump
HYDAC Hedec filters, filter cartridges, sensors
KRACHT Clark, Germany
VSE Germany