E-mail
k.wu@cs-instruments.cn
-
Phone
13601694498
-
Address
Room 508, 1080 Moyu South Road, Anting Town, Jiading District, Shanghai JT1166
Testing Instrument (Shanghai) Co., Ltd
k.wu@cs-instruments.cn
13601694498
Room 508, 1080 Moyu South Road, Anting Town, Jiading District, Shanghai JT1166
German CS Instrument VX 570 Steam Gas Liquid Flow Meter
High precision and versatile equipment integrating pressure and temperature compensation
Application scope:
• Measure saturated steam or superheated steam
• Measure liquids
• Measure mixed gases
• Measure corrosive media
Advantages Overview:
Measure standard volume flow rate, working volume flow rate, and mass flow rate
• Measurements are taken at temperatures up to 350 ° C
Measure at a maximum pressure of 63 bar (g)
• Suitable for unknown/changing gas compositions and mixed gases
• Corrosion resistance - All components in contact with the medium are made of stainless steel
• Not sensitive to vibration through reference vibration measurement
• No moving parts
Principle of vortex frequency function:

German CS Instrument VX 570 Steam Gas Liquid Flow Meter
Technical Specifications
measureQuantity range:Refer to the table
Measurement medium:Mainly single-phase gas, mixed gas, saturated steam, superheated steam, and liquid
precision-volumetric flow rate (m³/h):
gas /Steam:
± 1% of the measured value, (Re>20.000)
± 2% of the measured value, (10.000<Re<20.000)
Liquid:
± 0.75% of the measured value, (Re>20.000)
± 2% of the measured value, (10.000<Re<20.000)
mass flow rate (kg/h) or standard volumetric flow rate (Nm ³/h)
gas /Steam:
± 1.5% of the measured value, (Re>20.000)
± 2.5% of the measured value, (10.000<Re<20.000)
Measurement principle:eddy current -Vortex frequency measurement
Process temperature:-40…+350°C
Process pressure:highest 63 bar(g)
Protection level:IP67
Measurement of materials and components in contact with the medium:stainless steelSS304 (SS316 provided upon request)
Material aluminium -Alloy casting
Output signal: standard configuration:RS 485 (Modbus-RTU), 3x 4...20 mA,
optional:Ethernet interface
Power Supply:18…36 VDC
Measurement section:
Gas:1:30
Steam:1:35
Liquid:1:23
Viscosity:
DN 15 ≤ 4 mPas
DN 25 ≤ 5 mPas
DN 40...DN 300 ≤ 7 mPas
Repetition accuracy:± 0.3% of the measured value
Process interface:
flange DIN EN1092-1
flange ANSI
Middle flange