German CS Instrument VU 570 Ultrasonic Flow Meter
Used for industrial gases and mixed gases - integrated pressure and temperature compensation - with a larger measurement range than ordinary vortex flowmeters
Application scope:
•Industrial gases
• Mixed gas
Compressed air in PET
• Bottle production
• Liquid fossil oil and gas
• Propane Krypton Gas
Ultrasonic functional principle:

Advantages Overview:
Measure standard volume flow rate, working volume flow rate, and mass flow rate
• Suitable for unknown/changing gas compositions and mixed gases
Innovative measurement principles ensure accurate flow measurement in different gases
Suitable for rapidly changing temperature and pressure changes, as well as large mass flow rates
Advantages compared to traditional mechanical gas meters:
• No moving parts - no wear and tear
Advantages compared to traditional vortex street sensors:
Accurate measurement above 0.3 m/s
German CS Instrument VU 570 Ultrasonic Flow Meter
Technical Specifications
Measurement range:Refer to the table
Measurement medium:Air, non corrosive gases, and mixed gases (non condensing)
Accuracy:
volumetric flow rate (m³/h)
± 1.5% of the measured value, optional
± 1% of the measured value
mass flow rate (kg/h) or standard volumetric flow rate (Nm ³/h)
± 2% of the measured value, optional
± 1.5% of the measured value
Measurement principle:Vortex Ultrasonic Vortex Frequency Measurement
Process temperature:-40°…+100°C
Process pressure:highest 40 bar (g)
Protection level:IP67
Measurement of materials and components in contact with the medium:stainless steel 316, plastic
Material display unit:aluminium -Alloy casting
Output signal:
Standard configuration:RS 485 (Modbus-RTU),1x 4...20 mA, pulse
Optional: Ethernet interface
Power Supply:18…36 VDC
Measurement section:1:50
Repetition accuracy:± 0.3% of the measured value
Process interface:
flange DIN EN1092-1 or flange ANSI 150 lbs -300 lbs
R 1/2 "- R 2" (BSP British Standard Pipe)
1/2 "-2" NPT thread