GC-9860 Trace Hydrocarbon Chromatograph Automatic Gas Chromatography Analyzer
Air separation is currently the main method for industrial production of oxygen, nitrogen, and argon. Due to air pollution, hydrocarbons contained in the raw air enter the oxygen concentrator system, directly threatening safety production. The situation is quite serious Serious. In recent years, there have been hundreds or thousands of explosions in large, medium, and small air separation equipment both domestically and internationally due to excessive hydrocarbon content, resulting in astonishing direct and indirect losses. If detected at any time, the content of hydrocarbons can be predicted in advance, and measures can be taken early to prevent explosions.GC-9860The type of trace hydrocarbon analyzer can help you detect and predict in advance at any time, making it the choice for explosion-proof air separationOh
GC-9860The Type III trace hydrocarbon chromatograph is an automatic gas chromatograph that can continuously and automatically analyze trace hydrocarbons in liquid oxygen, liquid air, and suction air in air separation processes, and monitor explosive components C in real-timeThe changes in the content of 1-C4 provide important reference data for the safe operation of the main condenser in air separation equipment. It can also be used as a process controller for detecting hydrocarbons in industries such as petrochemicals, steel, and gas.
GC-9860Advantages of a type of trace hydrocarbon chromatograph: The pipeline extending from the air separation tower is connected to the instrument, and the instrument is controlled by a microcontroller automated program to drive an automatic six way valve for sampling and injection. As long as the analysis conditions and program settings are set, it can automatically detect hydrocarbons in liquid oxygen without human supervision. The experimental results are automatically printed out and the experimenters can directly take the experimental report.
Functions and characteristics of GC-9860 trace hydrocarbon chromatograph:
1. Automatic sampling, injection, and output analysis report. Automatic detection of three-way circulation of liquid air, liquid oxygen, and product oxygen, or single channel detection, with unmanned operation during automatic mode. 24-hour continuous online work.
2. The dedicated chromatographic column has a long service life and short analysis time, less than 5 minutes.
3. The detector has high sensitivity and low noise. The minimum detectable concentration of acetylene is 0.02ppm.
4. Choose between two detection components (four components and nine components).
5. Automatic progressive valve structure GC-9860 Trace Hydrocarbon Chromatograph Automatic Gas Chromatography Analyzer Novelty, long service life, continuous operation up to 100000 times without damage.
GC-9860Trace hydrocarbon chromatographDetection concentration:
group divide detection limit
CH4 (methane) 0.01ppm
C2H4 (ethylene) 0.01ppm
C2H6 (ethane) 0.01 ppm
C2H2 (acetylene) 0.01 ppm
C3H6 (propylene) 0.02 ppm
C3H8 (propane) 0.02 ppm
n-C4H10(正丁烷) 0.02 ppm
I-C4H10 (isobutane) 0.02 ppm
1,3-C4H8 (butadiene) 0.02 ppm
Adopting the FLASH memory system of *, data protection is no longer trapped by battery failure;
The highly stable and sensitive microcurrent amplification technology significantly improves the detection limit of FID;
The new thermal conductivity detector has higher sensitivity;
The instrument can be equipped with a built-in AD conversion circuit for direct digital output of chromatographic signals;
The instrument can be equipped with XS-H2000 workstation to complete all control and analysis tasks on a PC;
The instrument pneumatic system can be equipped with electronic flow display;
New pneumatic control valves ensure the repeatability of analysis parameters;
Capillary systems have split and split/non split injection modes;
● Rear door opening technology enables near room temperature operation and 9-stage programmed heating;
The instrument can be equipped with manual/automatic FID and FPD ignition devices;
Analysis of Dimethylamine and Trimethylamine by Gas Chromatography Manufacturer's Scheme
Flame photometric detector(FPD):
Detection limit:(S)≤5×10-11g/s ,(P)≤1×10-12g/s;
Baseline noise:≤3×10-13A
Baseline drift:≤0.2mV/30min
Linear range:≥103(S),102(P)
Method for making calibration curve for hydrogen sulfide analysis in natural gas:
Turn on the gas, turn on the machine, wait for the instrument to be ready, aboutAfter 10 minutes, ignite and wait for the baseline to stabilize.
Connect the standard gas cylinder directly to the inlet of the six way valve through a stainless steel tube, and the outlet of the six way valve is led out through a gas pipeline and connected to a beaker filled with water to absorb excessH2S。
Put four sets of low concentration standard gases into the chromatography separately, repeat each sample three times, calculate the average value through software, and then use software to calculate the standard curve
gas chromatographExperimental conditions:
Requirements for injection valve:Imported manual inert six way valve,install additionally1ml PTFE quantitative ring