Technical parameters:
model |
External dimensions (mm) |
External dimensions (mm) |
Internal dimensions (mm) |
Airflow rate (Inflow) |
Airflow rate (Sinking) |
power supply voltage |
AC2-2E8 |
730 x 753 x 1400 |
730 x 810 x 1400 |
610 x 580 x 660 |
0.45 m/s |
0.30 m/s |
230 V |
AC2-3E8 |
1035 x 753 x 1400 |
1035 x 810 x 1400 |
915 x 580 x 660 |
0.45 m/s |
0.30 m/s |
230 V |
AC2-4E8 |
1340 x 753 x 1400 |
1340 x 810 x 1400 |
1220 x 580 x 660 |
0.45 m/s |
0.30 m/s |
230 V |
AC2-5E8 |
1645 x 753 x 1400 |
1645 x 810 x 1400 |
1525 x 580 x 660 |
0.45 m/s |
0.30 m/s |
230 V |
AC2-6E8 |
1950 x 753 x 1400 |
1950 x 810 x 1400 |
1830 x 580 x 660 |
0.45 m/s |
0.30 m/s |
230 V |
Performance characteristics:
ULPA high-efficiency air filters have a 99% retention efficiency for 0.3 micron particle systems and a 99.995% retention efficiency for 0.1 micron particle systems.
The Esco's new Sentinel Gold ultra large screen microcomputer programmable system displays all safety information on one screen.
The airflow sensor will remind users if the airflow can provide higher safety.
The RS 232 serial interface will send operational information to the Building Management System (BMS).
Esco * * ISOCIDE antibacterial coating prevents bacterial and microbial contamination on the surface of the cabinet.
Single piece stainless steel workbench with arched design to prevent liquid leakage.
The operating chamber is formed by a single piece of steel plate, without joints or screws, and is easy to clean.
Optimize the isolation efficiency of the side interception zone and negative pressure side wall.
● Ergonomic design; Raising the armrest helps prevent the grille from intercepting and creates a more comfortable working posture.
● Available in the following size models: 0.6m (2 '), 0.9m (3'), 1.2m (4 '), 1.5m (5'), and 1.8m (6 ').
● Split type high-temperature sterilization worktable, easy to clean.
*According to American Standard IEST-RP-CC001, equivalent to HEPA H14 for EU-Standard EN1822
The Esco AirstreamA2 type secondary safety cabinet adopts a DCECM maintenance free fan system with a constant wind speed, and comes with voltage fluctuation compensation function to maintain a constant wind speed within a wide voltage fluctuation range of 190-250V; Equipped with resistance sensing compensation function, it can provide safe wind speed even when the filter blockage pressure increases by 30%. Adopting ULPA ji ultra high efficiency air filters with high safety performance, it can provide vertical laminar airflow to the workbench to protect the samples, while meeting the Class 1 air cleanliness standard (compliant with Class 3 of 1S0 1464.1 standard). The cabinet surface is coated with ESCO ISOCIDE antibacterial coating, which can effectively inhibit the growth of microorganisms on the cabinet surface. Compliant with EN 12469 certification, NSF/ANSI49 standard in the United States, and YY0569 standard in China.
Product Features:
Comes with wind speed compensation function
High Efficiency and Energy Saving
High cleanliness level in the workspace
Antibacterial coating on the surface of the cabinet reduces microbial contamination
Low noise and ergonomic design