Technical parameters:
model |
external dimensions (Length x Width x Height) |
internal dimensions (Length x Width x Height) |
Airflow rate (Inflow) |
Airflow rate (Sinking) |
power supply voltage |
|
1115 x 852 x 1540 mm (44.0' x 33.5' x 60.6') |
970 x 623 x 670 mm (38.2' x 24.5' x 26.4') |
0.53 m/s 105 (fpm) |
0.35 m/s 70 (fpm) |
220 VAC 50 Hz |
LA2-4A1 |
1420 x 852 x 1540 mm (56.0' x 33.5' x 60.6') |
1270 x 623 x 670 mm (50.0' x 24.5' x 26.4') |
220 VAC 50 Hz |
||
LA2-5A1 |
1725 x 852 x 1540 mm (68.0' x 33.5' x 60.6') |
1570 x 623 x 670 mm (61.8' x 24.5' x 26.4') |
220 VAC 50 Hz |
||
LA2-6A1 |
2030 x 852 x 1540 mm (80.0' x 33.5' x 60.6') |
1870 x 623 x 670 mm (73.6' x 24.5' x 26.4') |
0.33 m/s 65 (fpm) |
220 VAC 50 Hz |
|
LA2-8A1 |
2600 x 852 x 1540 mm (102.4' x 33.5' x 60.6') |
2440 x 623 x 670 mm (96.0' x 24.5' x 26.4') |
220 VAC 50 Hz |
Performance characteristics:
The new generation of DC electric motors in the United States serves as the operation center for safety cabinets.
The negative pressure meeting revolves around the polluted positive pressure area, and it is not recommended to use fabric bags.
The long service life ULPA air filter (per IEST-RP-CC001.3) for supply and exhaust filtration provides a retention efficiency of up to 99.999% for particles between 0.1 and 0.3 microns.
The operating chamber is formed from a single steel plate without joints or screws, making it easy to clean and sterilize.
The inclined airflow supply filter is matched with a safety cabinet shape to achieve uniform sinking airflow.
The Esco new Sentinel Gold ultra large screen micro computer programmable system displays all safety information on one screen.
Quick start mode, by moving the front window to the correct position, controls the on/off of the exhaust fan and lights.
RS 232 data output port for remote monitoring of operating parameters of the safety cabinet.
Frameless windows for easy cleaning.
Improve comfort from an ergonomic perspective.
Tilted display and control pad, compliant with ADA specifications.
Higher airflow grille design to prevent blockage.
Esco ISOCIDE antibacterial coating is applied to the painted surface to minimize the growth of bacteria.
Enhanced sidewall drainage hole design optimizes particle retention performance in the air.
Night mode/standby mode reduces power consumption while maintaining interception efficiency.
The ESCO LABCULTUREA2 secondary safety cabinet combines a large number of cutting-edge designs to provide multiple protections for operators, samples, and the environment, reducing maintenance costs and improving operational comfort and convenience.