E-mail
13526877955@139.com
-
Phone
13526877955
-
Address
1-818 Xinyuan Duhui Plaza, Daxue South Road, Zhengzhou City
Zhengzhou Junda Instrument Co., Ltd
13526877955@139.com
13526877955
1-818 Xinyuan Duhui Plaza, Daxue South Road, Zhengzhou City
Document from the Office of the State Administration for Market Regulation
Market Supervision Special Issue [2025] No. 52
Elevator car specific thickness gaugeTIME-N7
The General Office of the State Administration for Market Regulation on Further Improving Residential Housing
Notice on the Renovation of Old Elevators
Market Supervision Bureaus (Departments, Committees) of all provinces, autonomous regions, municipalities directly under the central government, and Xinjiang Production and Construction Corps:
In order to do a good job in updating old residential elevators supported by extra long term special treasury bond funds, and fully ensure the safety and convenience of residents, we hereby notify the following matters:
1、 Balancing safety and economy, effectively ensuring the quality and safety performance of elevators
1. Floor doors, elevator doors, and cars
(1) The floor sills and car fenders of the landing doors and sedan doors should be made of metal materials;
(2) The updated panel materials for metal layer doors, elevator doors, and cars shall consist of at least one layer of single metal sheet with a nominal thickness of not less than 1.5mm; The nominal thickness of the metal material panel of the reserved metal layer door shall not be less than 1.2mm; the engagement depth of the lower retaining device of the reserved layer door shall not be less than 15mm.
2、 Inspection equipment: Elevator panel thickness measuring kit, including the following contents:
Device Name |
Specification requirements |
purpose |
Digital Caliper |
indication error±0.01mm、 Calibration or verification certificates must be obtained. |
The direct measurement method is for detectionThe fundamental guarantee of work. |
Ultrasonic thickness gauge |
indication error±0.05mm(10mmWhen), calibration or inspection must be obtainedCertification is required. It is necessary to have the function of "coating thickness measurement" activated under painted conditions (including double-sided painted), without the need for polishing, to accurately measure the thickness of the metal body. It is also necessary to have real-time capabilitiesAScan signal display function (instead ofSnapshotAsweep”)In order to search for corrosion pits. At least the following accessories should be provided: a single crystal delay block probe (.≤4.5mm)Used for thickness measurementSearch for corrosion points and pits; One 'unequal thickness step test block' and two 'unequal thickness anti paint test pieces' (used to verify the instrument's ability to measure paint thickness). It is recommended that the thicknesses be500uAbout m, and1000uAbout m |
Quick measurement,
The part that cannot be measured by the caliperMeasure the position,
On the premise of having paint, there is no needPolish and accurately measure the thickness of the body. |
-Can display A-scan waveform for easy echo analysis and measurement of complex workpieces
-It has multiple measurement methods and can be set to blank to shield aftershocks or clutter;
-The instrument can adapt to various types of probes
-Penetrating coating measurement, layer by layer thickness measurement, and simultaneous display;
-Resolution of 0.001, 0.01, 0.1 millimeters is optional in any mode (or 0.0001, 0.001, 0.01)
Inches optional);
-Gain adjustment range 0-99dB;
-Adjustable voltage and variable pulse width square wave pulse generator;
-Equipped with single value B-scan display function;
-Equipped with alarm function, the upper and lower limits of the alarm can be freely set;
-Display mode with differences and maximum and minimum values;
-Can store up to 500000 measurement values and waveforms;
-Users can activate the fast measurement mode up to 20 times per second;
reverse measurement of sound velocityBased on the thickness of an object with unknown sound velocity, measure the sound velocity of the object in reverse
threeElevator car specific thickness gaugeTIME-N7 Performance Parameters
△ Display resolution |
0.001mm or 0.01mm or 0.1mm optional |
△ Speed adjustment range and measurement range |
0.1-600mm 508 m/s~18699m/s |
|
△ Repeatability |
comply withJJF 1126 5M and above probe repeatability: 0.03mm 2M and below probe repeatability: 0.1mm |
△ Probe parameters |
see details4.1- Probe parameters within the measurement range |
△ Display |
colorfulTFT LCD display, 320x240 pixels, 5-digit display, with backlight |
|
△ Measurement function |
High precision measuring tools suitable for measuring metals, plastics, ceramics, glass, and any other ultrasonic wavesA good conductor. Conventional measurement, minimum thickness capture, maximum thickness capture, difference, upper and lower limit LED alarm. |
|
Measurement of special materials |
Gain adjustment range:0-99dB; Shielding strip: The initial pulse bottom wave, interface wave bottom wave, and echo echo modes can be adjusted. Slope: adjustable to 11. The above three functions can be used in combination to measure various special materials, such as molybdenum containing stainless steel (316, 317, etc.), fiberglass, cast iron with extremely poor spheroidization rate, gray iron, etc. |
△ Set Lock |
Lock calibration data, etc |
△ pulse generator |
Adjustable square wave pulse generator |
△ I/O port |
USB communication |
△ Emission voltage |
60V, 110V, 150V, 200V optional |
△ Emission pulse width |
Change with probe frequency |
△ Gain range |
0-99dB, 1dB step |
△ Frequency range |
0.5 Mhz~20Mhz |
△ Measurement rate |
standard(4Hz)、 Fast (20Hz) |
△ Probe setting |
10 sets of fixed probe settings and 22 sets of custom probe settings |
△ Data storage |
500 data files, each capable of storing 1000 measurement values and waveforms |
△ Operating environment temperature |
0℃~40℃ |
△ Power supply |
According to customer requirements, three sections can be selectedNo.5 dry battery/nickel hydrogen rechargeable battery |
△ Working language |
Chinese, English |
△ Power consumption |
The working current does not exceed250mA (WiFi off, low brightness, at 4.5V) |
△ External dimensions |
187mm×87 mm×43 mm |
△ Shell |
Impact resistant, dust-proof, splash proof, compliant withIP65 |
△ Weight |
360g 左右 |
|
Applicable standards and specifications |
Q/HD SDF0001-2014 Ultrasonic Thickness Gauge JJF 1126-2004 Calibration Specification for Ultrasonic Thickness Gauge GB/T 6587 General Specification for Electronic Measuring Instruments |
▲ Standard configuration |
● Host ● 15MHz monocrystalline probe ● Coupling agent |