E+HProline Prowirl O Vortex Flow Meter
The specific parameters of the E+H Proline Prowirl O 200 vortex flowmeter are as follows:
• Measurement range: Liquid is 0.16-545m ³/h, steam and gas are 2-7262m ³/h;
Accuracy level: Liquid volume flow rate is ± 0.75%, steam and gas volume flow rate is ± 1.00%, liquid mass flow rate is ± 0.85%, steam and gas mass flow rate is ± 1.7%;
• Nominal diameter: DN15-DN150;
Work pressure: PN250, Class1500, 40K;
• Process temperature: PN63 to 160, Class600 from -200 to+400 ° C, PN250, Class900 to 1500 from -50 to+400 ° C;
• Environmental temperature: Compact (standard) is -40 to+80 ° C, Compact (optional) is -50 to+80 ° C, Remote (standard) is -40 to+85 ° C, Remote (optional) is -50 to+85 ° C;
• Sensor housing material: The sensor connection housing is made of AlSi10Mg and coated; 1.4408(CF3M);
• Material of transmitter housing: AlSi10Mg, coated; 1.4404(316L);
• Electronic plug-in protection: Compact type is IP66/67, 4X type housing, sensor remote type is IP66/67, 4X type housing, transmitter remote type is IP66/67, 4X type housing;
• Display/Operation: 4-line backlit display with touch control (can be operated externally), configurable through local display and operation tools, providing remote display;
• Output: 4-20mA HART (passive), 4-20mA (passive), pulse/frequency/switch output (passive);
E+HProline Prowirl O Vortex Flow Meter
• Input: 4-20mA (passive);
• 通信: HART,PROFIBUS PA,FOUNDATION Fieldbus;
• Power supply: DC12 to 35V (4-20mA HART with/without pulse/frequency/switch output), DC12 to 30V (4-20mA HART, 4-20mA), DC12 to 35V (4-20mA HART, pulse/frequency/switch output, 4-20mA input), DC9 to 32V (PROFIBUS PA, pulse/frequency/switch output);
• 防爆: ATEX,IECEx,cCSAus;
• Functional safety: Functional safety, metrological certification and certification, calibration on calibration facilities (compliant with ISO/IEC 17025), NAMUR, heartbeat technology meets the requirements of ISO 9001:2008 Section 7.6a (T Ü V certification) traceability verification;
Pressure certification and certificates: PED, CRN, AD2000;
Material certificate: 3.1 Material, NACE MR0175/MR0103, PMI (as required), only Class900/1500: Welding testing is conducted according to ISO15614-1, similar to ASME IX (as required).