E+H Thermal Mass Flow Meter Proline T-Mass
The specific parameters of the E+H Proline T-Mass F 300 thermal mass flowmeter are as follows:
Measurement error: Gas: 1.0% O.R. (10 to 99% O.F.S.), 0.1% O.F.S. (1 to 10% O.F.S.)
• Measurement range: 0.5 to 3750 kg/h (1.1 to 8250 lb/h)
• Medium temperature range: -40 ° C to+180 ° C (-40 ° F to+356 ° F)
• Process pressure: PN40/Cl.300/20K
• Material of liquid receiving components:
• Measuring tube: DN 15 to 50 (189 to 2 '): stainless steel cast steel, CF3M/1.4408; DN 65 to 100 (2 ݪ to 4 '): Stainless steel, 1.4404 (316/316L)
• Process connection: Flange connection: stainless steel, 1.4404 (F316/F316L); Threaded connection: stainless steel, 1.4404 (316/316L)
• Sensing element: Unidirectional: stainless steel, 1.4404 (316/316L); Alloy C22,2.4602 (UNS N06022); Bidirectional: Stainless steel, 1.4404 (316/316L); Reverse flow detection: stainless steel, 1.4404 (316/316L)
• Measurement principle: Thermal
• Sensor features:
High precision process control: high measurement accuracy and repeatability.
Reliable monitoring: capable of detecting process interference and reverse flow.
• Easy to maintain: The sensor is detachable.
E+H Thermal Mass Flow Meter Proline T-Mass
• Characteristics of the transmitter:
Access process and diagnostic information: Provides multiple freely combinable I/O and fieldbus options.
• Reduce complexity and diversity: I/O functionality can be freely configured.
• Integrated verification: heartbeat technology.
• Nominal caliber range: DN 15 to DN 100 (1/2 'to 4')
• Material of liquid receiving components:
• Measuring tube: DN 15 to 50 (189 to 2 '): stainless steel cast steel, CF3M/1.4408; DN 65 to 100 (2 ݪ to 4 '): Stainless steel, 1.4404 (316/316L)
• Process connection: Flange connection: stainless steel, 1.4404 (F316/F316L); Threaded connection: stainless steel, 1.4404 (316/316L)
• Measurement variables: mass flow rate, temperature, standard volume flow rate, volume flow rate, free air transport, velocity, heat flow rate, energy flow rate, density
• Environmental temperature range: -40 to 60 ° C (-40 to 140 ° F); Optional: Transmitter: -50 to 60 ° C (-50 to 140 ° F), Sensor: -60 to 60 ° C (-60 to 140 ° F)
• Material of transmitter housing: aluminum, AlSi10Mg, Coated polycarbonate
• Protection level: IP66/67, Type 4X enclosure
• Display/Operation: 4-line backlit display screen with touch control (can be operated from the outside); It can be configured through local display screens and operating tools; Provide remote display
• Output: 3 outputs: 4-20 mA HART (active/passive), 4-20 mA (active/passive), pulse/frequency/switch output (active/passive), relay output
• Input: Status input, 4-20 mA input
• Digital communication: HART, Modbus RS485
• Power supply: DC 24V, AC 100 to 240V
Explosion proof certification: ATEX, cCSAus, IECEx, NEPSI, JPN, UK Ex
Product safety: CE, C-tick
• Functional safety: Complies with the functional safety requirements of IEC 61508 and is suitable for safety related applications that comply with IEC 61511
• Metrological certification and certification: Calibration is conducted at accredited calibration facilities (compliant with ISO/IEC 17025); Heartbeat technology meets the requirements for measurement traceability in section 7.1.5.2 a of ISO 9001:2015
Pressure certification and certificates: PED, CRN
Material certificate: 3.1 Material NACE MR0175/MR0103