E+H modular resistance thermometer
There are multiple models of E+H modular resistance thermometers, and the specific parameters of the TM401 model are as follows:
• Measurement principle: Thermistor
• Features/Applications: British standard, sanitary application, anti-corrosion application, sanitary process connection, with extension neck, temperature sensor, non replaceable temperature sensor core
Material: 1.4435Ra<0.4 μ m, electronic polishing
• Response time: T90:1.5s
• Thermal protection sleeve: None (cannot be used in conjunction with thermal protection sleeve)
Armor core/probe: No replaceable armor core
• Outer diameter of thermal protection sleeve: 6.0mm (0.24 inches), 8.0mm (0.31 inches)
• Required insertion depth: 400mm (15.75 inches)
• Material of thermal protection sleeve: 316L
• Process connections: Collar threads, Tricap clamps, Microcap clamps, ISO2852 fittings, Ingold fittings G3/4'Liquiphant, G1'Liquiphant, Varivent, SMS1147, DIN11851 threaded pipe fittings
• End type of thermal protection sleeve: straight pipe type/reduced diameter type
E+H modular resistance thermometer
Surface smoothness Ra: 0.76 μ m (30 μ in), 0.38 μ m (15 μ in)
• Operating temperature range: PT100: -50... 200 ° C (-58... 392 ° F)
• Process pressure (static pressure): 40bar (580psi) at 20 ° C
Measurement accuracy: Cl. A, in compliance with IEC60751 standard
Modular temperature transmitter: Yes (4... 20mA, HART)
• Process connection: Chuck (micro chuck DIN11851, LiquiphantM, Ingold, Vari vent sterile type DIN11864, metal metal)
• Output signal: Pt100 3/4 wire system, 4... 20mA, HART, PROFIBUS PA/FF Foundation fieldbus
Certificate: SIL (transmitter only)