BOLOR quality providesGTMULP-10T intelligent water quality analyzer; Professional customized design with multiple parameter optionsReliable performance.
Domestic multi parameter water quality analyzerPrinciple:
This instrument contains optical and electrode methods (pH, conductivity TDS、 Dissolved oxygen and water temperature are used to measure water quality, and users can freely combine them according to their needs. Widely applicable for the determination of surface water and sewage.
Domestic multi parameter water quality analyzerFeatures:
*It can detect the concentration, absorbance, and transmittance of nearly a hundred parameters in water quality, and can store, print, query, and upload concentration values to a computer;
*Automatic selection of measurement wavelength;
*Adopting a large screen color touch operation, the interface is friendly and comes with operation guide assistance to explain various functional operations;
*In addition to up to 250 factory curves, users can add 3500 curves themselves, calibrate curves, and store them in the instrument;
*Store up to 100000 records (including parameter names, concentrations, units, detection times, operator numbers, etc.);
*The measurement method can be either the straight line method or the line method. Choosing the line method can achieve more accurate measurement of some parameters with poor linearity;
*It has a one click recovery function, which can achieve one click recovery when the factory curve and user curve data records are lost due to accidents;
*Backup measures can be taken for user calibrated curves and data records, and recovery operations can be carried out in case of accidental loss;
*Equipped with various security measures, it can set startup and system settings input passwords to prevent other personnel from accidentally operating the instrument settings;
*The light intensity can be adjusted, divided into 16 levels and set arbitrarily, which can effectively solve the problem of measurement range expansion caused by the strength of the signal;
*It is possible to query the curve, in addition to querying the curve equation, it is also possible to query the standard value and corresponding absorbance of each standard substance during calibration, as well as the standard value
*Set the time and calibration personnel number, reproduce the state of calibration;
*When querying records, single item printing or page printing can be performed;
*The system has bilingual functionality and can switch between Chinese and English.
As a partner of numerous enterprises, BOLOR Platinum has established strategic cooperation with you through its excellent quality and service.
| serial number | measurement items | Measurement range | unit | test error |
| 1 | COD (low range chromium method) | 5-200 | mg/L | 5% |
| 2 | COD (High Range Chromium Method) | 200-2000 | mg/L | 5% |
| 3 | Ammonia nitrogen (low range) | 0.02-5.00 | mg/L | 3%(F.S) |
| 4 | Ammonia nitrogen (high range) | 5.00-25.00 | mg/L | 3%(F.S) |
| 5 | Total phosphorus (low range) | 0.02-2.00 | mg/L | 5%(F.S) |
| 6 | Total phosphorus (high range) | 2.00-10.00 | mg/L | 5%(F.S) |
| 7 | Total nitrogen (low range) | 0.10-10 | mg/L | 5%(F.S) |
| 8 | Total nitrogen (high range) | 10-100 | mg/L | 5%(F.S) |
| 9 | CODMn (permanganate index) | 0.00-10.00 | mg/L | 0.2 or 5% |
| 10 | Residual chlorine (low range) | 0.02-2.00 | mg/L | 0.1 or 5% |
| 11 | Residual chlorine (high range) | 2.00-10.00 | mg/L | 5% |
| 12 | Total chlorine (low range) | 0.02-2.00 | mg/L | 0.1 or 5% |
| 13 | Total chlorine (high range) | 2.00-10.00 | mg/L | 5% |
| 14 | Chlorine dioxide (low range) | 0.05-2.00 | mg/L | 0.2 or 5% |
| 15 | Chlorine dioxide (high range) | 2.00-20.00 | mg/L | 5% |
| 16 | sulfate | 5-200 | mg/L | 5% |
| 17 | Nitrate (nitrogen) | 0.02-10.0 | mg/L | 0.1 or 5% |
| 18 | Phosphate (low range) | 0.01-10.0 | mg/L | 0.2 or 5% |
| 19 | Phosphate (high range) | 10.0-50.0 | mg/L | 5% |
| 20 | Nitrite nitrogen (low) | 0.02-1.0 | mg/L | 0.05 or 5% |
| 21 | Nitrite nitrogen (high) | 1.0-5.0 | mg/L | 5% |
| 22 | sulfide | 0.01-1.000 | mg/L | 5%(F.S) |
| 23 | fluoride | 0.05-2.0 | mg/L | 5%(F.S) |
| 24 | 0.01-0.50 | mg/L | 5%(F.S) | |
| 25 | bromide | 0.10-5.00 | mg/L | 5%(F.S) |
| 26 | formaldehyde | 0.05-2.5 | mg/L | 5%(F.S) |
| 27 | Volatile phenols (low) | 0.20-5.0 | mg/L | 5%(F.S) |
| 28 | Volatile phenols (high) | 5.0-10.0 | mg/L | 5%(F.S) |
| 29 | hydrazine | 0.01-0.50 | mg/L | 5%(F.S) |
| 30 | Aniline compounds (low) | 0.03-1.0 | mg/L | 5%(F.S) |
| 31 | Aniline compounds (high) | 1.0-5.0 | mg/L | 5%(F.S) |
| 32 | silicon dioxide | 0.01-5.00 | mg/L | 5%(F.S) |
| 33 | silicate | 0.01-5.00 | mg/L | 5%(F.S) |
| 34 | Total alkalinity (low) | 0-100 | mg/L | 5%(F.S) |
| 35 | Total alkalinity (high) | 100-1000 | mg/L | 5%(F.S) |
| 36 | Total hardness (low) | 0.1-5.0 | mg/L | 5%(F.S) |
| 37 | Total hardness (high) | 5.0-200.0 | mg/L | 5%(F.S) |
| 38 | Chloride ion (chloride) | 0.20-100.0 | mg/L | 5%(F.S) |
| 39 | ozone | 0.01-2.5 | mg/L | 5%(F.S) |
| 40 | Anionic surfactant | 0.01-1.0 | mg/L | 5%(F.S) |
| 41 | ammonium ion | 0.02-25.00 | mg/L | 5%(F.S) |
| 42 | available chlorine | 0.0-100.0 | mg/L | 5%(F.S) |
| 43 | chlorite | 0.00-20.00 | mg/L | 5%(F.S) |
| 44 | Cyanuric acid | 0-200 | mg/L | 5%(F.S) |
| 45 | urea | 0.00-4.00 | mg/L | 5%(F.S) |
| 46 | Copper (low) | 0.02-1.0 | mg/L | 5%(F.S) |
| 47 | Copper (high) | 1.0-10.0 | mg/L | 5%(F.S) |
| 48 | zinc | 0.2-5.0 | mg/L | 5%(F.S) |
| 49 | Nickel (low) | 0.02-0.50 | mg/L | 5%(F.S) |
| 50 | Nickel (high) | 0.50-1.00 | mg/L | 5%(F.S) |
| 51 | nickel | 0.02-10.0 | mg/L | 5%(F.S) |
| 52 | Iron (low) | 0.0-5.0 | mg/L | 5%(F.S) |
| 53 | Iron (High) | 5.0-10.0 | mg/L | 5%(F.S) |
| 54 | Ferrous (low) | 0.0-5.0 | mg/L | 5%(F.S) |
| 55 | Ferrous (high) | 5.0-10.0 | mg/L | 5%(F.S) |
| 56 | hexavalent chromium | 0.01-1.00 | mg/L | 5%(F.S) |
| 57 | cadmium | 0.05-0.50 | mg/L | 5%(F.S) |
| 58 | Manganese (low) | 0.01-0.10 | mg/L | 5%(F.S) |
| 59 | Manganese (high) | 0.10-1.0 | mg/L | 5%(F.S) |
| 60 | manganese | 0.02-5.00 | mg/L | 5%(F.S) |
| 61 | Total chromium | 0.02-1.0 | mg/L | 5%(F.S) |
| 62 | Aluminum (low) | 0.01-0.40 | mg/L | 5%(F.S) |
| 63 | Aluminum (high) | 0.40-4.00 | mg/L | 5%(F.S) |
| 64 | silver | 0.01-1.00 | mg/L | 5%(F.S) |
| 65 | molybdenum | 0.05-1.00 | mg/L | 5%(F.S) |
| 66 | Arsenic (low) | 0.004-0.100 | mg/L | 5%(F.S) |
| 67 | Arsenic (high) | 0.100-0.500 | mg/L | 5%(F.S) |
| 68 | 铍 | 0.001-0.10 | mg/L | 5%(F.S) |
| 69 | boron | 0.10-2.00 | mg/L | 5%(F.S) |
| 70 | mercury | 0.002-0.50 | mg/L | 5%(F.S) |
| 71 | lead | 0.01-0.50 | mg/L | 5%(F.S) |
| 72 | antimony | 0.50-10.0 | mg/L | 5%(F.S) |
| 73 | Chromaticity (low range) | 5-50 | PCU | 3%(F.S) |
| 74 | Chromaticity (high range) | 50-500 | PCU | 3%(F.S) |
| 75 | turbidity | 0-400 | NTU | ≤2%(F.S) |
| 76 | suspended solids | 5-1000 | mg/L | ≤2%(F.S) |
| 77 | PH (colorimetric method) | 5.00-8.00 | PH | 0.1±0.1 |
| 78 | PH (electrode method) | 0.00-14.00 | PH | ±0.1 |
| 79 | Dissolved oxygen (colorimetric method) | 0.1-10.0 | mg/L | 0.1±5% |
| 80 | Dissolved oxygen (electrode method) | 0-20.0 | mg/L | ±0.2 |
| 81 | Conductivity (electrode method) | 0.00µs/cm-199.9ms/cm | ms/cm | ±1.0% (F.S) |
| 82 | TDS (electrode method) | 0.0mg/L~199.9g/L | g/L | ±0.5% (F.S) |
| Dissolver | |
| Temperature control range: | Room temperature can be set between 200 ℃ |
| Temperature control accuracy: | ±0.5℃ |
| Dissolving time: | 1-9999min adjustable |
| Batch processing capacity: | 16 water samples (optional 20, 25, 36) |
| Power consumption: | 220VAC,<500W |
| display screen: | 3.5-inch color touch screen with a resolution of 320 × 240, displaying switching between Chinese and English |
| Overall dimensions: | 355mm × 260mm × 135mm (excluding protective cover) |
| Weight: | GTDR-16:5.5kg(GTDR-20:6.5kg、GTDR-25:7.0kg、GTDR-36:8.0kg) |
| Standard configuration: | 1 host (standard 16 hole), 1 protective cover, 1 power cord, 1 user manual, 1 product certificate and 1 warranty card |
| parameter type | parameter value |
| Measurement items: | COD、 Ammonia nitrogen, total phosphorus, total nitrogen, copper, iron, nickel, hexavalent chromium, phosphate, nitrite PH、 More than 80 parameters, including residual chlorine, can be found in the "Measurement Item Table" below. Users can customize parameters according to their needs |
| Number of optical channels: | Customizable 1-16 channels |
| Wavelength optional: | 340,420,440,470,520,540,560,610,630,660,680,700nm |
| Electrochemical method parameters: | Temperature, PH, Conductivity, dissolved oxygen |
| light source | Imported high-performance LED |
| Detector: | Silicon photoelectric sensor |
| Wavelength accuracy: | Center wavelength ± 1nm |
| Absorption range: | -2.0001~2.000 |
| Colorimetric linearity: | ±0.002A(0-1A) |
| Colorimetric accuracy: | ± 0.005A/1A |
| Repeatability: | ≤2% |
| Optical stability: | ≤0.002A/20min |
| Electrochemical method for determining parameters and ranges | |
| temperature | 0.0~100.0C |
| Dissolved oxygen: | 0.0~20.0mg/L |
| PH: | 0.00~14.00PH |
| Conductivity: | 0.0ps/cm~200.0ms/cm |
| monitor: | Color touch screen, switching between Chinese and English |
| Reading mode: | Concentration, absorbance, and transmittance |
| Colorimetric method: | 比色管 (Ф16mm、Ф25mm) 和比色皿 |
| Power Supply: | AC220V(165V~240V),30W |
| Instrument size: | 400mm×300mm×140mm |
| Instrument weight: | 2.6kg |
| Host power consumption: | <10W |
| Work environment: | Temperature range of 5-40C, humidity not exceeding 90% |
| Storage environment: | Temperature -40~60 ℃, humidity not exceeding 90% |