Desktop thermal conductivity tester (heat flow method) thermal resistance meter

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Mainly used to test the thermal resistance of thin thermal conductors, solid electrical insulation materials, thermal conductive silicone grease, resins, rubber, beryllium oxide ceramics, alumina ceramics and other materials, as well as the contact thermal resistance and thermal conductivity of materials at solid interfaces. The detection material is a solid sheet, and with a surrounding frame, it can detect powder and paste materials. Instrument reference standard: MIL-I-49456A (insulation sheet, thermal conductive resin, thermal conductive fiberglass reinforcement); GB 5598 (Method for determination of thermal conductivity of beryllium oxide ceramics); ASTM D5470-2012 (Test Standard for Heat Transfer Properties of Thin Thermal Conductive Solid Electrical Insulation Materials), GB/T 2

Product Details

DRL-V desktop thermal conductivity tester (heat flow method), thermal resistance tester

(Upgraded type)

1、 Introduction:

Mainly used to test the thermal resistance of thin thermal conductors, solid electrical insulation materials, thermal conductive silicone grease, resins, rubber, beryllium oxide ceramics, alumina ceramics and other materials, as well as the contact thermal resistance and thermal conductivity of materials at solid interfaces. The detection material is a solid sheet, and with a surrounding frame, it can detect powder and paste materials. Instrument reference standard: MIL-I-49456AInsulation sheet, thermal conductive resin, and thermal conductive fiberglass reinforcement; GB/T 5598-2015Method for determination of thermal conductivity of beryllium oxide ceramicsGB/T 29313Test Method for Thermal Conductivity Performance of Electrical Insulation Materials in 2017;ASTM D5470-2017Test standards for heat transfer performance of thin thermal conductive solid electrical insulation materials, etc.

DRLThermal conductivity meter using heat flow methodaccording toASTM D5470-2017The standard requires design and manufacturing. Our company has accumulated 20 years of experience in production, manufacturing, and user practice, which has continuously improved and matured the performance of this product.Adopting servo motor control for precise automatic pressurization and automatic thickness measurement deviceAnd connected to a computer to achieve fully automatic control. The instrument adopts6Point temperature gradient detection improves testing accuracy. A protective thermal device has been added around the test rod inside the test head (to provide thermal protection for the sample), reducing the impact of ambient temperature on the test. It can test the thermal resistance curve under different pressures and temperatures, and use optimized mathematical models to measure multiple parameters such as material thermal conductivity, thermal resistance, and interface contact thermal resistance.Adopting new technology for automatic compensation of cold end temperature,No longer need to add ice water compensation device.

Users can choose standard and small-sized models (with the same performance) according to their actual land occupation, saving laboratory space.

Widely used in material thermal conductivity analysis and testing in universities, research institutions, quality inspection departments, and production plants.

2、 Main technical parameters:

1Thermal conductivity testing range: 0.01~50W/m.k,5~500W/m.k (high conductivity test mode), automatically switched by computer software;

2Thermal resistance test range: 0.05-500cm2.k/w ;

3Sample size: Φ 30mm or 20x20mm (standard configuration). Other sizes such as Φ 15, Φ 50, 25.4x25.4mm can be customized, According to the contract agreement, any items not specified shall be configured according to the standard;

4Sample thickness: 0.001-50mm (standard configuration), typical thickness: 0.02-20mm;

5Hot electrode temperature control range: Room temperature~99.99 ℃ (standard configuration), Room temperature~299.9 ℃, Room temperature~500℃, optional for users, as stipulated in the contract. For those not specified, standard configuration shall be followed;

6Cold pole temperature control range: 0-99.99.00 ℃, temperature control accuracy of 0.01 ℃ (equipped with high-precision, large capacity low-temperature water tank);

7. Pressure measurement range: 0-1000N, controlled by servo motor, can accurately set the pressure value for holding pressure, control accuracy0.1N;

8. Thickness measurement range: 0-50.00mm, resolution accuracy0.001mm,Automatic thickness measurement

9. Sample quantity: 1 piece (thin film or multiple pieces can be stacked).

10. Thermal conductivity and thermal resistance test error: ≤ 3%; Contact thermal resistance test error: ≤ 5%.
11. Experimental method:

a、 Thermal resistance testing of samples under different pressures; b、 Material thermal conductivity testing;

c、 Contact thermal resistance test under different pressures of the medium; d、 Thermal resistance test of aluminum substrate (composite sheet);

e、 Aging reliability testing; f、 Thermal conductivity testing of high thermal conductivity materials (equipped with a high conductivity testing module)

g、 Contact thermal resistance testing between samples under different pressures (with contact thermal resistance testing module); h、 Material compression performance testing.

12. Fully automated computer testing and implementation of data printing and output;

13. Power supply:220V/50Hz; 1000W。

3、 Typical test materials

1. Metal materials, aluminum, copper, and alloy materials;2. Thermal conductive silicone and silicone grease;

3. Thermal conductive silicone pad; 4. Engineering plastics, electrical insulation materials;

5. Thermal conductive tape (the sample is very thin and sticky, making it difficult to make regular individual samples, fixed with transparent plastic on one side and paper on the other);

6. Aluminum substrate and copper-clad laminate materials; 7. Quartz glass, alumina, composite ceramic materials;

8. Foam copper, graphite paper, graphite sheet, carbon felt and other new materials.

4、 Completeness

1One host 2. One set of analysis software (in both Chinese and English versions);

3. HX-1008 precision low-temperature constant temperature water bath (temperature control accuracy 0.01 ℃);

4. One Lenovo computer (user selectable); 5. Two standard samples;

6. One set of random accessories (one set of grease, paste, and powder test boxes, and one set of sheet forming stamping molds for easy sampling).

5、 Dimensions and weight

1Small desktop models: (length x width x height)) 500×400×780mm, Net weight:60Kg

2. Precision low-temperature constant temperature water bath: (length × width × height) 320 × 370 × 670mm, Net weight: 35Kg.

6、 Technical Services

1. Free one-year warranty, long-term technical service, and lifetime free software upgrades.

2. Free on-site installation and debugging across the country. Our company has mobile technical personnel throughout the country who can provide technical services