Welcome Customer !

Membership

Help

Xiangtan Xiangyi Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Xiangtan Xiangyi Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    Xiangtan Xiangyi Instrument Co., Ltd., Xiaotang Road, German Industrial Park, Xiangtan High tech Zone, Hunan Province

Contact Now

Desktop high-precision material thermal conductivity meter (flat plate heat flow meter method)

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Adopting the internationally popular method of using a heat flux meter to measure thermal conductivity and resistance, coupled with a computer to achieve fully automatic detection and generate experimental reports. The instrument uses a stable hot surface temperature added to one side of the sample, and heat is transferred to the cold surface through the sample. The heat transfer is measured to calculate the thermal conductivity and thermal resistance. Adopting imported sensors and computer technology, it has the characteristics of good measurement accuracy, high reliability, and good repeatability. Especially suitable for measuring low thermal conductivity (accurate to 0.1mW). It can be used for testing plastics, rubber, thermal insulation materials, aerogel plates, vacuum glass, etc., and is widely used in colleges, research institutes, quality inspection, factories and mines.

Product Details

DRPL-VIII desktophigh precisionMaterial Thermal Conductivity Tester(Flat plate heat flux meter method

1Overview

Adopting the internationally popular method of using a heat flux meter to measure thermal conductivity and resistance, coupled with a computer to achieve fully automatic detection and generate experimental reports. The instrument uses a stable hot surface temperature added to one side of the sample, and heat is transferred to the cold surface through the sample. The heat transfer is measured to calculate the thermal conductivity and thermal resistance. Adopting imported sensors and computer technologyThe characteristics of good measurement accuracy, high reliability, and good repeatability. Especially suitable for measuring low thermal conductivity (accurate to 0.1mW). Can be used for plastic, rubber, and insulation materialsAir gel plate, vacuum glassWaiting for testing, widely used in colleges and universities, research institutes, quality inspection, factories and mines.

Reference standardGB/T10295-2008 (Determination of steady-state thermal resistance and related characteristics of insulation materials - Heat flux meter method) andASTME1530,ASTM C518-04 Test Method for Determining Steady State Heat Flux and Heat Transfer Characteristics by Heat Flux Meter Method.

2、 Main technical parameters

1Range and accuracy of thermal conductivity: 0.00011W/mk, measurable and accurate to0.1mw/mk.

0.001~300W/mk.

2. Measurement accuracy:1%.
3Sample size: 50×50~150×150mm),Thickness not exceeding50mm

4Can test solid materials and powder materials. 5Measurement time1520min.
6Hot surface temperature and control: room temperature
99.9 ℃ (standard configuration),room temperature499.9℃,Higher can be determined according to user requirements temperature Flat panel heater, bidirectional thyristor control,temperature control accuracy0.1℃。
7Cold face temperature and control:0
99.9 ℃ (standard configuration), -1099.9℃,Lower temperatures can be determined according to user requirements. Cold noodles are water-cooled,Ensure stable temperature of cold noodles (precision constant temperature water bath, adjustable temperature),temperature control accuracy0.1℃。
8The sample is precisely pressurized and clamped using a computer,pressure range0
1000N,resolution0.1N.
9Automatic measurement of sample thickness, 0V50mm,resolution0.1um.
10Adopting imported original heat flow meter,Stable and reliable performance.
11The entire process adopts computer automatic testing and printing to store experimental data.

3、 Completeness

1One host;

2One set of analysis software (in both Chinese and English versions);

3TheHX-1005One precision low-temperature constant temperature water bath (temperature control accuracy)0.01℃);

4One Lenovo computer (user selectable);

5One standard sample;

4、 Dimensions and weight

1Small desktop model: (length x width x height) 500 x 400 x 780mm, Net weight: 60Kg

2Precision low-temperature constant temperature water bath: (Long)X Width x Height)300×350×530mm , Net weight: 35Kg .

5、 Technical Services

1Free one-year warranty, long-term technical service, and lifetime free software upgrades.

2Free on-site installation and debugging across the country. Our company has mobile technical personnel throughout the country who can provide technical services.

DRPLSeries Thermal Conductivity Tester(Flat plate heat flux meter method)Partial user list

serial number

Unit Name

1

Henan Fanrui Yihui Composite Materials Co., Ltd. 3 units

2

Shanghai Motor Vehicle Testing and Research Center

4

Huahui (Jiangsu) Testing Technology Co., Ltd./2 units in Taizhou

5

Hebei Aibei Aihe New Materials Co., Ltd. 3 units

6

Henan Audemars Piguet Love River New Materials Company 2 units

7

Jiangsu Anjia New Material Technology Co., Ltd. 2 units

8

四川省建材研究院

9

Center for Space Application Engineering and Technology, Chinese Academy of Sciences

10

2 units from Saint Gobain R&D (Shanghai) Co., Ltd

11

Beijing Mucheng Fireproof Insulation Special Materials Co., Ltd

12

Nanjing University of Chemical Technology Suqian New Materials Base 2 units

13

Jiangsu Dazheng Material Technology Co., Ltd

14

Changsha Gree Electric Appliance Co., Ltd