Technical Parameter
|
·Pressure measurement range
|
Minimum 0~1m, maximum 0~350m
|
|
|
·Pressure measurement accuracy
|
0.1% FS, 0.2% FS, 0.5% FS (comprehensive error includes linearity, hysteresis, and repeatability)
|
|
|
·Temperature measurement range
|
-20℃~150℃
|
|
|
·Temperature measurement accuracy
|
± 1 ℃, ± 2 ℃
|
|
|
·Allowable medium temperature
|
Standard type -20~+80 ℃; High temperature type -20~+150 ℃
|
|
|
·Compensation temperature
|
Standard type -20~+85 ℃; High temperature type -20~+120 ℃
|
|
|
·Allow storage temperature
|
Standard type -40~+80 ℃; High temperature type -40~+150 ℃
|
|
|
·Pressure accuracy
|
0.2%, 0.1% accuracy level, full temperature range ± 0.5% (based on 20 ℃)
|
|
|
Temperature influence
|
accurate 0.5% precision level full temperature range ± 1% (based on 20 ℃)
|
|
|
·Pressure signal output
|
4-20mA two-wire analog signal; 4~20mA two-wire system simulation
|
|
|
|
Signal with HART communication protocol function; MODBUS protocol RS485 output
|
|
|
|
Type; Special requirements agreed upon
|
|
|
·Power supply
|
Analog type (12.5-30) V DC; Intelligent (12~36) V DC
|
|
|
|
Intrinsic safety type (8-24) V DC; RS485 output type (12~36) V DC
|
|
|
·Long term stability
|
Better than 0.15% FS in two years
|
|
|
·Allow environmental humidity
|
95%HR
|
|
|
·Contact with medium
|
Sensor -316L or special requirements; Measuring Sensor Object -316L
|
|
|
Partial materials
|
Or special requirements; Cable - PU (polyurethane rubber, up to 80 ℃)
|
|
|
|
FEP (perfluoroethylene propylene, up to 150 ℃)
|
|
|
Other electrical parameters
|
|
|
|
·Preheating time
|
Simulated 200ms; Intelligent type: 2ms
|
|
|
·Corresponding time
|
Simulation type: 60ms; Intelligent type: 230ms
|
|
|
·Damping
|
Analog type: 2s; Intelligent type: 0-32s
|
|
|
·Electromagnetic compatibility
|
The radiation immunity of radio frequency electromagnetic fields complies with GB/T17626.3-1998
|
|
|
|
10V/m, compliant with Class A standards; The conduction impedance of RF field induction meets the requirements
|
|
|
|
GB/T17626.6-1998 U=10V, compliant with Class A
|
|
|
·Explosion proof mark
|
Exia II C T6 Ga; Explosion proof certificate number: CE14.2068
|
|
|
·Parameters
|
Ui:30V DC、li:120mA、Pi:0.9W、Li:0mH、Ci:0.02μF
|
|
|
·Allow overload pressure
|
150% F.S below 20MPa; 150% F.S at 20~30 MP
|
|
|
·Protection level
|
IP68
|