Welcome Customer !

Membership

Help

Beijing Chuangshi Yunbo Technology Development Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Beijing Chuangshi Yunbo Technology Development Co., Ltd

  • E-mail

  • Phone

  • Address

    No. 88 Fuxing Road, Haidian District, Beijing

Contact Now

Contact Us - Panasonic High Pressure Sterilizer Beijing After sales Maintenance Center

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Contact Us - Panasonic High Pressure Sterilizer Beijing After sales Maintenance Center; 400/002/1991, Panasonic/Sanyo full range high-pressure sterilization pot fault repair service in Japan.

Product Details

Contact Us - Panasonic High Pressure Sterilizer Beijing After sales Maintenance Center;400 002 2991; 010--5726--1824.


Panasonic high-pressure sterilization pot operation alarm maintenance, Panasonic high-pressure sterilization pot non heating maintenance, Panasonic high-pressure sterilization pot air leakage maintenance, Panasonic high-pressure sterilization pot pressure increase maintenance, Panasonic high-pressure sterilization pot non startup maintenance, Panasonic high-pressure sterilization pot non drainage maintenance, Panasonic high-pressure sterilization pot trip maintenance, Panasonic high-pressure sterilization pot maintenance.

 

Daily maintenance and upkeep of Panasonic high-pressure sterilizer:

When stacking sterilized items, it is strictly prohibited to block the outlet of the steam valve. A space must be left to ensure smooth air release of the equipment. Otherwise, the safety valve cannot work due to the blocked outlet, causing accidents.

2. Before each use of the high-pressure sterilizer, it is necessary to check whether the water level in the sterilization bucket is maintained at the foot rest.

When sterilizing liquid, it should be bottled in a hard heat-resistant glass bottle with a volume not exceeding 3/4. The bottle mouth should be sealed with cotton yarn, and unperforated rubber or cork stoppers should not be used.

Special attention: Do not release steam immediately after the sterilization liquid is finished. The residual gas can only be discharged after the pressure gauge pointer returns to zero.

4. Do not sterilize items of different types and with different sterilization requirements, such as dressings and liquids, together to avoid neglecting one and causing losses.

5. When the sterilization of the high-pressure sterilizer is completed, the pressure gauge pointer must return to zero position, and the release valve should be placed in the release position. Allow external air to enter the high-pressure sterilizer, and after the vacuum is eliminated, the container lid can be opened.

6. If the pressure gauge of the high-pressure sterilizer is used for a long time and the pressure indication is not correct or cannot return to zero, it should be repaired in a timely manner. It should be regularly compared with the standard pressure gauge. If it is not normal, a new gauge should be replaced.

7. The high-pressure sterilizer should be kept clean and dry in order to extend its service life. Rubber sealing gaskets will age over time and should be replaced regularly.

  

Principle of Panasonic high-pressure steam sterilization pot;

The principle of high-pressure sterilization is that in a closed steamer, the steam cannot escape, and the pressure continues to rise, causing the boiling point of water to continuously increase, thereby increasing the temperature inside the steamer. Under a pressure of 0.1 MPa, the temperature inside the pot is 121. At this steam temperature, various bacteria and their highly heat-resistant spores can be quickly killed.

Pay attention to eliminating the air inside the pot, so that the pot is completely filled with water vapor, and sterilization is necessarycompleteThere are several different methods for high-pressure sterilization and deflation, but the purpose is to clear the air and evenly heat up the pot to ensure sterilizationeffectThe common method is to close the vent valve, turn on the power, and when the pressure reaches 0.05MPa, open the vent valve to release air. After the pressure gauge pointer returns to zero, close the vent valve. After closing the valve and energizing, when the pressure reaches 0.1 MPa, start timing and maintain the pressure at 0.1-0.15 MPa for 20 minutes.

  

Panasonic high-pressure sterilization pot product features:

1. The space saving and easy-to-use high-pressure steam sterilizer allows you to perform sterilization operations anytime, anywhere when needed. The MLS-3781 and MLS-37511 high-pressure steam sterilizers are designed for independent laboratories and can be easily pushed from one laboratory to another by rollers. MLS-3751 has a lower height and can be placed under the laboratory control panel when not in use.

2. Unbelievable large chambers, although these high-pressure steam sterilizers have small and compact external dimensions, can accommodate 8 (MLS-3751) or 12 (MLS-3781) 1000ml flasks. MLS-3751 has two baskets, while the larger MLS-3781 has three.

3. Compact design, easy to access flip up, both models can be easily installed in a small space. The flip up cover allows you to easily and conveniently place and remove test tubes, flasks, and laboratory equipment.

4. The voice prompt function increases security, avoids misoperation, and enhances accuracy. Standard mode: For the safety of product use, precautions and operating instructions will be notified through voice prompts; Warning mode: If the security protection mechanism is activated during use, this product will stop running and a voice prompt will inform the user to confirm/check the items. In addition, reminders will be sent for regular maintenance.

5. The newly designed handle allows users to easily open and close the lid with one hand. The traditional sliding handle has been redesigned and evolved into a manual pull method, which can be easily opened and closed with one hand. In addition, there is a heat-resistant plate under the lid to prevent steam burns.

6. A cooling fan with reduced cooling time, several exhaust holes added to the side of the product, and a standard cooling fan installed below the chamber have improved cooling and sterilization efficiency.

7. Equipped with exhaust volume adjustment function, the constant opening and closing level of the exhaust valve (5-level adjustment) allows you to choose the steam discharge rate in the chamber, reducing cooling time while reducing exhaust time and preventing excessive boiling of sterilization liquid.

8. Optional thermal printer, through a serial thermal dot matrix printer, can print the working status (temperature/chamber pressure, sterilization process, time) displayed on the operation panel for record keeping, management, and storage.

9. Microprocessor temperature control, controlling the fluctuation of sterilization temperature within the set temperature (115 ℃~135 ℃)+2 ℃/-0 ℃.

10. Exhaust control can be set to automatically release air after sterilization is completed.

11. Configure 4 optional processes and 3 custom programs, choose one of the 4 processes based on usage purposes, and save 3 types of settings for each process based on usage conditions. It is easy to change the settings of various programs (sterilization temperature, sterilization time, melting temperature, melting time, insulation, exhaust temperature, exhaust rate) for convenient use by users.


Panasonic High Pressure Sterilization Pot Repair Service Commitment

(1) Timely reflect user needs;

(2) Provide high-quality and affordable products to ensure timely delivery;

(3) Strictly control product quality;

(4) Properly package to prevent omissions and damage.

In short, we not only provide users with qualified products, but also offer high-quality services, establishing a good image in the industry and leaving a deep impression on users.

Contact Us - Panasonic High Pressure Sterilizer Beijing After sales Maintenance Center.