- Phone
-
Address
Chengdu Development Zone, Sichuan Province
Sichuan Kailisen Instrument Manufacturing Co., Ltd
Chengdu Development Zone, Sichuan Province
performance parameters | |
accuracy class |
Level 0.5 |
Environmental temperature impact |
≤±0.2%/10℃ |
long-term stability |
≤± 0.2%/URL (12 months) |
The impact of installation location |
The influence of any installation position can be corrected through zero point fine-tuning |
Static pressure influence |
≤± 0.1%/range/1.0Mpa |
response time |
0.25s |
Power supply impact |
≤±0.005%/URL/V |
vibration impact |
≤±0.25%/URL/g |
Operating Temperature |
-40~315℃ |
environment/Storage temperature |
-40~70℃ |
use/Storage humidity |
≤95%RH |
Radiation interference (shell) |
30MHz-1000MHz |
Conducted interference (power port) |
0.15MHz-30MHz |
surge immunity |
220V |
power supply |
24V DC |
Load range |
Current type load resistorRL(≤Us-Umin)/0.03 |
Instrument diagnostic function |
When the instrument malfunctions, output an alarm current |
Display variables |
Percentage, current, main variable(g/cm³、kg/m³) |
HART communication requires voltage |
(18.5-24)V |
Shell material |
Cast aluminum baking paint (default), stainless steel304, stainless steel 316L |
Protection level |
IP65 |
Sensor diaphragm |
316L (default) HC、 Tantalum, 316L gold-plated |
Sensor filling fluid |
Silicone oil (default), fluorine oil, high-temperature silicone oil, vegetable oil |
The relationship between power supply voltage and load |
load resistorRL calculation formula: RL=(Vs-12)/0.025(Ω) RL load resistance value (Ω) Vs - Power Supply Voltage (V) |
Coal washing online density meterIts core working principle is based on the formula P=ρ gh for liquid static pressure difference. There are two pressure sensors (or pressure relays) inside the instrument, which are installed at a fixed vertical distance (h). The sensor measures the pressure difference (Δ P) generated by the liquid column, and with the known local gravity acceleration (g) and height (h), the density (ρ) of the liquid can be calculated. To ensure accuracy, devices usually have built-in temperature sensors (such as PT1000) that automatically compensate for changes in medium temperature.