gas analyzerUE610 - O2It uses the principle of paramagnetic cross pressure to measure the oxygen content in corrosive gases, and can be used in general safety areas and special explosion-proof areas.
Technical specifications
Measuring range:
|
Detection range Measure small values Measure large values Measurement range (including zero correction) characteristic Control Panel The measurement results show that Electromagnetic Compatibility installation orientation size weight Measurement response: Noise (electronic time constant)1s, Range2) A small amount of process0.5%(The small quantity is indicated on the nameplate) zero drift<Small range on the label0,5% / 3moon Measurement drift<Each range's0,5% / 3moon reproducibility<Each range's1% Influencing variables: ambient temperature < 0.5% / 10 K sample gas pressure No pressure compensation: range based< 2%,1%Changes in pressure Pressure compensation: range based< 0.2%,1%Changes in pressure Residual gas Zero drift corresponding to magnetism or diamagnetic drift of residual gas (See operating manual)AD 55 0012) Sample gas flow rate<The small possible range on the nameplate1%Within the allowed flow range Within the scope, there are0,1 l/minChanges in traffic volume Electronic input and output: analog output 0 / 2 / 4~20mAFloating load750 relay output 6Different contacts can be freely set, such as range recognition: AC/DC 24 V / 1Afloat Analog input 2Group, used for0/2/4~ 20 mACorrection of external pressure sensors and residual gas effects (correction of cross effects) Binary input 6, used for24VFloating, freely adjustable, such as range selection serial interface RS 485 Optional parts Additional electronic accessories:8A binary input and8Binary output, such as automatic calibration trigger Climate conditions: Allowable ambient temperature-30~ +70 °CStorage and transportation environment +5 to +45 °CWorking environment Allow humidity Annual average< 90% RHDuring storage and transportation protection levelIP 20 (EN 60529) |
Multi range automatic switching 0~ 2% v/vor5% v/v O2 100% v/v O2 When the standard gas is passed, in0~100%v/vof Any zero point between them is possible (see reference gas table) linear Liquid crystal display,LEDBacklight and contrast control, soft buttons, numeric keys, function keys 4½ -bit,Depending on the selected measurement range; Optional decimal numbers part, Front panel vertical 19”, 4 HU = 177 x 483 x 476 mm about20Kg |
power supply
AC 200 ~ 240 V, 48~63 Hz(Rated range: 180 V to 264 V)
energy loss about35 VA
Inlet conditions:
sample gas pressure ±0,5~±1,5Ba (flexible hose);
±0,5~±3 Ba (pipeline)
Sample gas flow rate20~ 60 l/h (0,3 ~ 1 l/min.)
sample gas temperature0~50 °C
sample gas humidity< 90% RH
Response time:
warm-up time at room temperature< 30 min
Display delay time(T90)1.5~3.5sDepending on the model
Attenuation (electronic time constant)0~100s, can be set
Death time about0,5 ~2,5Depending on the model