Capacitive voltage divider high voltage measurement system 50KV

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The capacitive voltage divider high voltage measurement system is 50KV, using precision high voltage thin film capacitors and precision high voltage glass glaze resistors. The input impedance is high, reducing the test current, reducing power consumption, and improving the measurement accuracy and stability of the tester

Product Details

Precautions for use

When using this device, there should be no debris around to avoid affecting the measurement accuracy.

2. Strictly maintain the operating distance to ensure safe operation.

3. Check the reliable connection of each part, especially the firm connection of the ground wire.

4. After the measurement is completed, enter the site only when the instrument measurement shows zero.

5. Overpressure use is strictly prohibited, and attention should be paid to surface cleanliness. When not in use, it should be stored in a cool and dry place. A voltage divider is a specialized instrument used for on-site measurement, which can measure both the average value of DC high voltage and the effective value of AC high voltage. The entire equipment consists of a voltage divider and a measuring instrument. The voltage divider adopts a balanced equipotential shielding structure, with high-quality electronic components inside and installed in an insulated cylinder filled with transformer oil, making the entire device accurate in testing, linear, stable in performance, structurally reasonable, easy to carry, simple in operation, and intuitive in display. Therefore, it is an ideal instrument for on-site measurement.


Capacitive voltage divider high voltage measurement system 50KV

Product Introduction

Used for power system frequency AC and DC high voltage testing, the AC/DC digital high voltage divider has voltage levels of 50kv, 100kv, 150kv, and 200kv, consisting of a high voltage divider and a low voltage display meter, connected by matching cables for use.

The signal acquisition is carried out using precision high-voltage thin film capacitors and precision high-voltage glass glaze resistors. The internal filling material is imported from abroad, making the structure small, lightweight, and has a small local discharge. The FRC series AC/DC digital voltage divider is connected to the high-voltage measuring terminal through an instrument line and is a good product for measuring AC/DC high voltage. The FRC series AC/DC digital high voltage divider can achieve clear readings from a long distance, safe and convenient to use, and adopts special shielding technology to reduce the influence of high voltage on the indication, thereby achieving high stability and high linearity.

AC/DC voltage divider is a universal high-voltage measuring instrument that can be used in power systems, electrical and electronic equipment manufacturing departments to measure power frequency AC high voltage and DC high voltage. During operation, the high-voltage part and low-voltage instrument are separated, ensuring safe and reliable operation.


Capacitive voltage divider high voltage measurement system 50KV

technical indicators

Accuracy: AC: Level 1.5, DC: Level 1.0 or AC: Level 1.0, DC: Level 0.5

Voltage division ratio K=high pressure/low pressure=1000:1 (measured high pressure value=1000 x value in low pressure gauge).

Electrical strength: 1.2 times the rated voltage

Environmental conditions: temperature 0-40 ℃, humidity: below 85%

voltage level

AC/DC50kV

AC/DC100kV

AC/DC200kV

AC/DC300kV


voltage division ratio

1000:1

1000:1

1000:1

1000:1


impedance

200MΩ

400MΩ

800MΩ

1200MΩ


accuracy

DC value

1.0 or 0.5 level

1.0 or 0.5 level

1.0 or 0.5 level

1.0 or 0.5 level

Communication value

Level 1.5 or 1.0

Level 1.5 or 1.0

Level 1.5 or 1.0

Level 1.5 or 1.0









Precautions

1. There should be no debris on the test site to avoid affecting the measurement accuracy.
2. The ground wire must be securely connected to ensure a safe operating distance.
3. After the experiment is completed, it must be fully discharged and display "O" before the testing personnel can enter the site.
4. It is strictly prohibited to use beyond the rated voltage.
5. Ensure the surface of the equipment is clean and store it in a cool, dry place.

电容分压器高压测量系统 50KV