Product Overview:
Mainly used for measuring power frequency AC or DC high voltage. Can replace high-voltage electrostatic voltmeter. It has the characteristics of easy operation, intuitive display, high accuracy, small size, and light weight. Suitable for power plants, substations, high-voltage electrical equipment manufacturing plants, and high-voltage testing laboratories as ideal equipment for high-voltage measurement.
This instrument is equipped with a dedicated high-precision 31/2-digit voltage divider digital display instrument, which is connected to the voltage divider tube through the instrument line, and can achieve clear readings from a distance. It is safe and convenient to use. This instrument has a high input impedance, which can reduce the impact on the output of the high-voltage power supply. This instrument can be easily disassembled and placed in a packaging box, making it easy to carry and move, and bringing convenience to on-site inspection work. Welcome to choose.
Usage:
1. Safely ground the grounding terminal of the standard voltage divider.
2. Connect the high-voltage wire above the voltage equalizing ball and tighten it with a wiring screw.
3. Insert the input terminal on the instrument base into the measuring terminal of the voltage divider. As it is a resistive voltage divider, the toggle switch should be switched to the "DC" position (without AC measurement function, the toggle switch is invalid when switched to the "AC" position)
When the measured voltage is less than 200kV, select the "LOW" mode. When it exceeds 200kV, select the "HIGH" mode to obtain higher precision test values.
5. Turn on the "Power" switch and select the appropriate gear. At this point, the voltage divider will display "00.00" or "000.0", and measurement can begin.
6. After the test is completed, the high voltage should be cut off first. Only when the reading on the voltage divider is "00.00" or "000.0", can the site be entered (after the measurement is completed, the tested object should be discharged first, and the site can only be entered when the voltage on the voltage divider is zero).
When measuring DC, if there is a filtering capacitor, it should be fully discharged first until the reading indicated by the voltage divider is "0.000" before other operations can be performed.
During use and maintenance, attention should be paid to the cleanliness of the surface of the voltage divider to prevent contamination,
The instrument should be placed in a dry place and properly stored.
9. Compatible with oscilloscope interface. If voltage waveform display is required, simply connect the voltage divider directly to the oscilloscope.
technical indicators
Voltage divider ratio |
1000 : 1 |
|
Voltage divider accuracy |
AC:1.0%, DC:0.5% |
|
Insulation medium of voltage divider |
DuPont dry dielectric materials from the United States |
|
Communicating measurement methods |
True effective value measurement |
|
environmental conditions |
temperature |
0~40℃ |
humidity |
≤85%RH |
|
FRC-50kv |
Dimensions: 200 * 200 * 550mm3 |
|
weight |
6.3kg |
|
FRC-100kv |
Dimensions: 200 * 200 * 850mm3 |
|
weight |
8.2kg |
|
FRC-150kv |
Dimensions: 370 * 270 * 1030mm3 |
|
weight |
14kg |
|