Benzene detector X-pid 9000 toxic and harmful gas measuring instrument
Dr ä ger X-pid 9000/9500 does not require preparation and can be used immediately after quick startup. The selective measurement in the "analysis" mode can be completed in just a few seconds. To perform benzene measurement, simply press the button and it will take 30 seconds to complete. After a 60 second interval, the device can measure benzene again. Compared to other detection systems, Dr ä ger X-pid 9000/9500 can save a lot of time and enable further monitoring. Simultaneously measuring other compounds such as benzene and butadiene further reduces detection time.

Benzene detector X-pid 9000 toxic and harmful gas measuring instrument
9000/9500 sensor unit.Raw & & X-pid
List of target compounds in 9000/9500 "Analysis" mode
Raw & & X-pid
The target compounds of 9000 are limited to benzene and 1,3-butadiene. Dräger X-pid
9500 is suitable for the following target compounds.
Compound CAS number
Acrylic Quan 107-02-8
Benzene 71-43-2
1,3-Butadiene 106-99-0
2-butanone 78-93-3
Butyl acrylate 141-32-2
Chlorobenzene 108-90-7
1,1-Dichloroethylene 75-35-4
Cis-1,2-dichloroethylene 156-59-2
Trans-1,2-dichloroethylene 156-60-5
Epichlorohydrin 106-89-8
Ethyl acetate 141-78-6
Ethyl acrylate 140-88-5
Ethylbenzene 100-41-4
Ethylene oxide 75-21-8
N-hexane 110-54-3
Isobutene 115-11-7
Methyl acrylate 96-33-3
Methyl Bromide 74-83-9
Phosphine 7803-51-2
Epoxy propane 75-56-9
Styrene 100-42-5
Tetrachloroethylene 127-18-4
* 109-99-9
Toluene 108-88-3
Trichloroethylene 79-01-6
Order Information
Explain the order number
Raw & & X-pid
9000, including sensor unit, control unit, pre installed mobile applications, power supply, and charging
Wire, test gas adapter, and dust-proof and waterproof filtration membrane
6851847
Raw & & X-pid
9500, including sensor unit, control unit, pre installed mobile applications, power supply, and charging
Wire, test gas adapter, and dust-proof and waterproof filtration membrane
6851848
Raw & & X-pid
9500 AUS/SGP, Including sensor unit, control unit, and pre installed mobile applications, electricity
Source, charging cable, test gas adapter, and dust-proof and waterproof filtration membrane
6850014
Raw & & X-pid
9500 CAN, Including sensor unit, control unit, pre installed mobile application, power supply
Charging cable, test gas adapter, and dust-proof and waterproof filtration membrane
6850015
将 Dräger X-pid
Mobile application upgraded from version 9000 to version 9500 6851849
Testing and Calibration Gas 58L
10ppm isobutene, 10ppm toluene
6814046
Test gas 58 l
Benzene 5ppm
6814050
Pressure reducing valve basic model 0.5 LPM; Suitable for 58L test gas cylinder 6810397
Raw & & X-pid
9000/9500 Test Gas Adapter 6851850
Raw & & X-pid
9000/9500 outer box 6851851
Polyethylene sampling hose, including PTFE lined hose
Length (3 meters); Outer diameter: 8 millimeters; Inner diameter: 4.8 millimeters; Wall thickness: 1.6 millimeters
8326980
Polyethylene sampling hose, including PTFE lined hose
Length (15 meters); Outer diameter: 8 millimeters; Inner diameter: 4.8 millimeters; Wall thickness: 1.6 millimeters
4594679
Sampling hose FKM (resistant to organic solvents)
Outer diameter: 6.4 millimeters; Inner diameter: 3.2 millimeters; Wall thickness: 1.6 millimeters
8325837
Dustproof and waterproof filtration membrane, including hose adapter 8319364
Dustproof and waterproof filtration membrane, without hose adapter 8319359
Expansion probe ES 150
Maximum length of 150 centimeters, including FKM sampling hose extension tube
8316533
Rod probe 90
Length: 90 centimeters, including FKM sampling hose extension tube
8316532
Floating ball probe, excluding hose 6802337