Benzene detector X-pid 9000 toxic and harmful gas measuring instrument

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

DRAEGER Benzene is an organic compound, a simple aromatic hydrocarbon with the chemical formula C6H6. It is a colorless and transparent liquid that is sweet, flammable, carcinogenic, and toxic at room temperature. It is difficult to dissolve in water, easily soluble in organic solvents, and can also be used as an organic solvent itself

Product Details

Benzene detector X-pid 9000 toxic and harmful gas measuring instrument

Dr ä ger X-pid 9000/9500 does not require preparation and can be used immediately after quick startup. The selective measurement in the "analysis" mode can be completed in just a few seconds. To perform benzene measurement, simply press the button and it will take 30 seconds to complete. After a 60 second interval, the device can measure benzene again. Compared to other detection systems, Dr ä ger X-pid 9000/9500 can save a lot of time and enable further monitoring. Simultaneously measuring other compounds such as benzene and butadiene further reduces detection time.

637835841584782427639.jpg


Benzene detector X-pid 9000 toxic and harmful gas measuring instrument

The following technical specification data is only applicable to Dr ä ger X-pid9000/9500 sensor unit.
Dimensions (width x height x depth) approximately 132 x 281 x 56 millimeters
Weight approximately 880 grams (2 pounds)
Temperature -10 to+35 ° C
Pressure range of 700 to 1300 millibars
Working environment conditions
Relative humidity: 10% to 95%
Protection level IP54
About 10 minute start-up phase
May be prolonged in low temperature environments
The working time is usually 8 hours, which decreases with the decrease of ambient temperature
short
ATEX II 1G Ex ia IIC T4 Ga
IECEx Ex ia IIC T4 Ga
CCSAus Class I, Class 1, Group A, Group B, Group C, Group D
T4、Ex ia
Category I, Zone 0, A/Ex ia IIC T4 Ga
RED (Directive 2014/53/EU)
certification
CE marking
ATEX (Directive 2014/34/EU)

Raw & & X-pid

List of target compounds in 9000/9500 "Analysis" mode
Raw & & X-pid

The target compounds of 9000 are limited to benzene and 1,3-butadiene. Dräger X-pid

9500 is suitable for the following target compounds.
Compound CAS number
Acrylic Quan 107-02-8
Benzene 71-43-2
1,3-Butadiene 106-99-0
2-butanone 78-93-3
Butyl acrylate 141-32-2
Chlorobenzene 108-90-7
1,1-Dichloroethylene 75-35-4
Cis-1,2-dichloroethylene 156-59-2
Trans-1,2-dichloroethylene 156-60-5
Epichlorohydrin 106-89-8
Ethyl acetate 141-78-6
Ethyl acrylate 140-88-5
Ethylbenzene 100-41-4
Ethylene oxide 75-21-8
N-hexane 110-54-3
Isobutene 115-11-7
Methyl acrylate 96-33-3
Methyl Bromide 74-83-9
Phosphine 7803-51-2
Epoxy propane 75-56-9
Styrene 100-42-5
Tetrachloroethylene 127-18-4
* 109-99-9
Toluene 108-88-3
Trichloroethylene 79-01-6


Order Information
Explain the order number
Raw & & X-pid

9000, including sensor unit, control unit, pre installed mobile applications, power supply, and charging
Wire, test gas adapter, and dust-proof and waterproof filtration membrane
6851847
Raw & & X-pid

9500, including sensor unit, control unit, pre installed mobile applications, power supply, and charging
Wire, test gas adapter, and dust-proof and waterproof filtration membrane
6851848
Raw & & X-pid

9500 AUS/SGP, Including sensor unit, control unit, and pre installed mobile applications, electricity
Source, charging cable, test gas adapter, and dust-proof and waterproof filtration membrane
6850014
Raw & & X-pid

9500 CAN, Including sensor unit, control unit, pre installed mobile application, power supply
Charging cable, test gas adapter, and dust-proof and waterproof filtration membrane
6850015
将 Dräger X-pid

Mobile application upgraded from version 9000 to version 9500 6851849
Testing and Calibration Gas 58L
10ppm isobutene, 10ppm toluene
6814046
Test gas 58 l
Benzene 5ppm
6814050
Pressure reducing valve basic model 0.5 LPM; Suitable for 58L test gas cylinder 6810397
Raw & & X-pid

9000/9500 Test Gas Adapter 6851850
Raw & & X-pid

9000/9500 outer box 6851851
Polyethylene sampling hose, including PTFE lined hose
Length (3 meters); Outer diameter: 8 millimeters; Inner diameter: 4.8 millimeters; Wall thickness: 1.6 millimeters
8326980
Polyethylene sampling hose, including PTFE lined hose
Length (15 meters); Outer diameter: 8 millimeters; Inner diameter: 4.8 millimeters; Wall thickness: 1.6 millimeters
4594679
Sampling hose FKM (resistant to organic solvents)
Outer diameter: 6.4 millimeters; Inner diameter: 3.2 millimeters; Wall thickness: 1.6 millimeters
8325837
Dustproof and waterproof filtration membrane, including hose adapter 8319364
Dustproof and waterproof filtration membrane, without hose adapter 8319359
Expansion probe ES 150
Maximum length of 150 centimeters, including FKM sampling hose extension tube
8316533
Rod probe 90
Length: 90 centimeters, including FKM sampling hose extension tube
8316532
Floating ball probe, excluding hose 6802337