In the field of pharmaceuticals and medical devices, the initial adhesion of products such as Babu plaster and transdermal patch is a key indicator for evaluating their user experience and effectiveness. Jinan Xio Electromechanical has launched a professional level product based on a deep understanding of pharmaceutical packaging and adhesive testingBabu initial adhesion testerIntended to provide customers with precise and efficient solutions for quantifying initial adhesion force. This instrument strictly follows the internationally recognized probe testing method and scientifically evaluates its initial adhesion performance by simulating the brief contact pressure and separation process during the initial use of the product.
This instrument integrates high-precision measurement, intelligent control, and professional adaptability. Its core advantages include:
Professional probe method testingStrictly based on the principle of Probe Tack Test, standard 5mm precision grinding flat probe is equipped for contact, maintenance and constant speed separation using standardized procedures, directly measuring the maximum separation force with objective and accurate data, suitable forBabu initial viscosity test.
High precision and repeatabilityAdopting imported high-precision force sensors and a stable PLC motion control system, the measurement accuracy is as high as ± 0.5%, effectively ensuring the reproducibility of test results and meeting the strict quality control and R&D comparison requirements of the pharmaceutical industry.
Intelligent operation experienceEquipped with a 7-inch high-definition touch screen (HMI), the user interface is user-friendly, allowing for intuitive setting of key parameters such as contact force, holding time, separation speed, and real-time display of force time curves, making operation simple and intuitive.
Efficient testing processEquipped with automatic reset function of the measuring head, it will automatically return to the starting position after a single test is completed. Equipped with a built-in micro printer, it can instantly print test results and brief reports, significantly improving batch testing efficiency.
Powerful functional expansion capabilityThe test speed can achieve stepless speed regulation within the range of 1-500mm/min. The instrument platform has good scalability and can be easily extended to other platforms by replacing fixtures or probesInitial adhesion test of tapeorAdhesive typeProduct evaluation.
This equipment is described according to standards such as ASTM D2979Probe type initial adhesion testing machineGeneral methods. The instrument drives a flat probe with a specified diameter (such as 5mm) to descend at a constant speed and apply a set contact pressure to the adhesive layer on the surface of the sample. After maintaining a preset short period of time, the probe is lifted vertically in reverse at a constant speed to separate from the sample. The force sensor monitors the resistance throughout the separation process and records its peak value. The peak force value is defined as the "initial adhesion" of the sample, scientifically reflecting the adhesive properties exhibited by the material under mild and transient pressure.
| parameter item | Technical Specifications |
|---|---|
| Range of force measurement | 0-200N (standard, other ranges can be customized) |
| Accuracy of force measurement | ±0.5% |
| Test speed range | 1-500 mm/min, Stepless continuous adjustable |
| Displacement resolution | 0.01mm |
| Standard probe | Φ 5mm stainless steel flat probe (other specifications can be customized) |
| data output | 7-inch touch screen display, built-in micro printer |
| power supply | AC 220V 50Hz |
The design and testing methods of this instrument comply with the following major international standards and specifications:
International Standard:ASTM D2979-Standard test method for adhesive properties of pressure-sensitive adhesive tapes (probe method). This isProbe type initial adhesion testerThe core method standards.
Industry application referenceIts testing principle is widely used to evaluate the initial adhesion of medical pressure-sensitive adhesives, Babs, transdermal patches and other products, and is one of the effective testing methods in the pharmaceutical and medical device industries.
This instrument is a key equipment for product development and quality control in the following industries:
Pharmaceutical and Babu productionSpecially designed forInitial adhesion of Babu agentThe determination of adhesion properties between the plaster and the backing layer, as well as between the plaster and the skin during the initial contact period, is an important step in the factory inspection of products such as Babu plaster and traditional Chinese medicine plaster.
Medical device manufacturingUsed to test the initial adhesion of disposable heart electrodes, pain relief patches, heating patches, and adhesive tapes, and evaluate their positioning and fixation ability during use.
Adhesive industryServing pressure-sensitive adhesive (PSA) manufacturers, used for various adhesive tapes, self-adhesive labels, protective films, and other productsInitial adhesion testResearch and development of formulas.
Research and Quality SupervisionProvide standard testing tools for drug inspection institutes, third-party testing institutions, universities, and research institutes for product performance research, quality evaluation, and standard setting.
Jinan Xio Electromechanical is well aware of the specific challenges faced by different customers in material testing, and therefore provides deeply customized solutions:
Customized specialized testing fixturesDesign and manufacture specialized sample fixing fixtures and testing platforms for special patches of different sizes and shapes (such as irregular Babu patches, small-sized electrode sheets) or samples that are difficult to fix.
Personalized development of testing programsWe can customize non-standard contact pressure, holding time, separation angle, or complex multi cycle testing procedures according to customer product standards or internal research needs.
Special environment simulation integrationCustomizable integrated temperature control module, enabling operation under specific temperature conditions (such as human skin temperature)Initial adhesion testMake the testing conditions more closely aligned with actual usage scenarios.
Data interface and report customizationProvide a test data export interface or customize software report templates according to customer requirements. We are committed to ensuring that every deviceBabu initial adhesion testerWe can accurately solve customers' specific testing needs and become a reliable partner for improving product quality and R&D efficiency.