Atomic absorption spectrometer (six lamp position, flame method)

NegotiableUpdate on 01/08
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The CAAM-2024C atomic absorption spectrometer (six lamp position, flame method) is equipped with high-performance dual cathode power supply. The instrument has a built-in circuit that can use high-performance element lamps (dual cathode element lamps) to avoid unstable factors caused by the use of external current adapters.
Product Details

1、 Product Introduction:

CAAM-2024C 型Atomic absorption spectrometer (six lamp position, flame method)It is jointly developed by multiple industry experts in China and renowned professors from Tsinghua University. It mainly uses flame atomic absorption analysis method, and also has multiple functions such as flow injection hydride atomic absorption method and graphite furnace atomic absorption method. It is a physical and chemical analysis instrument with many functions and high cost-effectiveness. Professors Wu Tingzhao and Chen Lianyuan, who developed this instrument, are experts in the atomic absorption industry in China for many years and have experience in developing various types of instruments. They have combined their years of experience to improve the sensitivity of element testing in atomic absorption spectrometers to a new level. Their technology enables the sensitivity of flame atomic absorption to reach a high level, that is, 1 μ g/ml/Cu absorbance ≥ 0.3 (sensitivity<0.015 μ g/ml/1% A).

2、 Detection methods and detectable trace elements of atomic absorption spectrometer (for reference only):

Atomic absorption flame method (air acetylene) can detect elements up to PPM level.

Sodium (Na), potassium (K), magnesium (Mg), calcium (Ca), chromium (Cr), manganese (Mn), iron (Fe), cobalt (Co), nickel (Ni), platinum (Pt), gold (Au), copper (Cu), silver (Ag), zinc (Zn), cadmium (Cd), lead (Pb), bismuth (Bi), lithium (Li), etc.

IIICAAM-2024C 型Atomic absorption spectrometer (six lamp position, flame method)Main Features

1. High performance lamp power supply: Equipped with high-performance dual cathode power supply, the instrument has a built-in high-performance element lamp (dual cathode element lamp) circuit to avoid unstable factors caused by the use of external current adapters.

2. When adjusting the combustion assistance ratio of the flame atomizer, the equipment's gas path box adopts a dual gas path control flow method, truly achieving flow control of gas and auxiliary gas. Due to the fact that many manufacturers only observe the flow rate of combustion assistance gas and rely solely on adjusting the gas flow rate, they cannot achieve true combustion assistance ratio regulation. Especially when making samples of organic components, the reliability of this aspect is highlighted. Some manufacturers can only reduce the output pressure of the auxiliary gas if they want to change the flow rate of the auxiliary gas, which brings a lot of unnecessary cumbersome processes to the operation.

3. The monochromator adopts a gap elimination screw sine mechanism for spectral separation, eliminating the phenomenon of backlash and return difference in the transmission mechanism, and achieving faster wavelength scanning speed.

4. Multiple slits are adopted, and special slits for high-temperature elements that can be used in the visible light region are specially added to avoid some elements that cannot be detected or the detection results are unreliable.

5. The control of the Element Lamp Lighthouse adopts dual synchronous wheel and dual synchronous belt technology to improve accuracy, ensure smooth, precise, and reliable operation.

6. Core key components:

1) Photomultiplier tube: Original Hamamatsu brand.

2) Grating: Developed by Changchun Institute of Optics and Fine Mechanics, Chinese Academy of Sciences

4、 Workstation Introduction

Software features

Instructions

Metal element detection

Capable of detecting element concentrations and net absorption values based on set elements, measurement time, delay time, etc., and generating curves.

Unknown sample detection

Capable of detecting the absorbance, concentration, relative deviation, etc. of unknown samples.

Report Generation

Capable of generating elemental determination data reports, including detection conditions, standard sample measurement results, standard working curves, unknown sample measurement results, etc.

instrument calibration

Can calibrate instruments based on the selected lamp position, negative high voltage, etc.

chart plotting

Ability to generate working curves by selecting fitting methods, concentrations, etc

Automatic peak searching

Calculate the position based on the selected element and generate the corresponding wavelength.

Element lamp control

Ability to select lamp position, set current and voltage, and set preheating lamp position.

Automatic ignition

Can control the device to ignite the combustion head.

Smart Alarm

It can detect the temperature of the graphite furnace head, gas pressure, cooling water flow rate, etc. When the data is abnormal, it will automatically alarm and stop heating.



原子吸收光谱仪(六灯位,火焰法)


原子吸收光谱仪(六灯位,火焰法)

5、 Technical parameters

1. Working conditions

1.1 Power Requirements: 220V (+5%~-10%), 50/60 Hz; 5000VA。

1.2 Environmental temperature:+15 ℃ to+35 ℃.

1.3 Relative humidity: 20-80%.

2. Technical indicators

2.1 Spectral system

2.1.1 Grating lines: 1800 lines/mm.

2.1.2 Wavelength range: 190-900nm.

2.1.3 Spectral bandwidth: automatically adjustable in five levels: 0.1, 0.2, 0.4, 1.0, and 2.0nm.

2.1.4 Wavelength accuracy: ± 0.15nm, wavelength repeatability: ≤ 0.05nm.

2.1.5 Baseline drift: Static ≤± 0.002A/30 minutes, dynamic ≤± 0.004A/30 minutes.

2.1.6 Light source: Six light positions, automatic switching of turret, secondary limit control technology, automatic collimation.

2.1.7 High performance power supply: Built in 2 high-performance lamp dual cathode power supplies.

2.2火焰原子化器

*2.2.1 Characteristic concentration (Cu): 0.015 μ g/mL/1%.

*2.2.2 Detection limit (Cu): 0.002 μ g/mL.

*2.2.3 Precision: RSD ≤ 0.5%.

2.2.4 Combustion head: Metal titanium combustion head.

2.2.5 spray: metal sheathed high-efficiency glass atomizer.

2.2.6 Atomization chamber: Explosion proof and corrosion-resistant polymer material atomization chamber.

2.2.7 Adjustment System: Fully automatic PC controlled six lamp brick tower, automatic alignment, automatic optimization, and automatic ignition.

2.2.8 Safety protection: It has automatic safety protection function, automatic gas path protection against backfire, acetylene leakage alarm, automatic shutdown system, and automatic power-off in case of abnormalities.

2.2.9 Background correction: Deuterium lamp background correction: capable of correcting 1A background.

2.3 Data Processing

*2.3.1 Measurement methods: flame method, hydride method

2.3.2 Concentration calculation method: Standard curve method (1-3 degree curve), automatic fitting, standard addition method.

2.3.3 Repeat measurement times: 1-99 times, calculate the average, provide the standard deviation and relative standard deviation.

2.3.4 Result printing: Parameter printing, data result printing, graphic printing, can export WORD and EXCEL documents.

2.3.5 Full Chinese interface, simple and convenient operation, can rotate the light position and automatically ignite through software operation.

*2.3.6 Communication Interface: The computer communicates with the host via USB interface.

6、 After sales technical service institutions and commitments

Our after-sales technical service organization is headquartered in Beijing, with external offices in Nanjing, Zhengzhou, Chengdu, Kunming, Shijiazhuang, Lanzhou, Wuhan, and other provinces and regions across the country. Our aim is to enable customers to use our instruments effectively, respond promptly, solve problems they encounter, and use them with peace of mind.

Service commitment:

Our company guarantees to strictly ship the goods according to the delivery deadline specified in the supply contract.

2. Our company guarantees that the initial user who purchases this instrument will receive a one-year (12-month) warranty from the date of installation and commissioning. Free software upgrades will be provided within 10 years, and the instrument will be serviced with spare parts for no less than 15 years.

3. After the warranty period, our company adheres to the after-sales service principles of "giving one cent profit for one cent reputation" and "no profit service". Repairs will only be charged for the cost of parts (or discounted by 20% of the quoted price) and half price labor costs, with low travel expenses.

4. After installation and debugging, the user should fill out the maintenance and installation card in detail and return it to our company. Our company will archive the detailed information. If the instrument malfunctions, please contact our company in a timely manner. The company will respond within 24 hours after receiving the repair notice. Under normal circumstances, service personnel will arrive at the scene within 48 hours, and the latest response time should not exceed one week.

5. The instrument is provided by our company for free installation, debugging, and training of technical personnel in the user's location. We also assist in providing analysis methods. Users can come to our company for technical learning at any time according to their needs. Training and learning are free of charge, and accommodation and meals are provided by themselves.

Our company holds at least one user technical training course per year. Users can decide on their own when to attend the training based on the usage of the instrument. Regularly follow up with users every quarter to assist them in solving analysis problems encountered during use in a timely manner.

If the user's spare parts are damaged, they can directly purchase from our company, and the company will send them by express delivery or send someone to deliver them.

7、 Standard configuration list

serial number

name

unit

quantity

Remarks

1

Host

Taiwan

1

Six light positions, automatic adjustment

2

air compressor

Taiwan

1


3

Computer

Taiwan

1

Brand desktop computer

4

printer

Taiwan

1

Brand inkjet printer

5

nebulizer

a

2

Metal covered glass high-efficiency atomizer

6

Hollow cathode lamp

only

3

Three optional elements for users to choose from

7

power supply cable for the main unit

root

1


8

Host signal line

root

1

USB signal cable

9

dual-purpose screwdriver

a

1


10

1.5A fuse

a

2


11

3A fuse

a

2


12

Protect the ground wire

root

1

Instrument back connection

13

Acetylene pipe clamp

a

3


14

Acetylene pipe joint

a

1


15

Acetylene gas source pipe

rice

3


16

waste liquid pipe

rice

1.5

ф10mm

17

Gas pipeline

rice

5

ф6mm

18

Packing List

copy

1


19

Warranty Card

copy

1


20

Certificate of Conformity

copy

1


21

Inspection Report

copy

1


22

Technical CD

copy

1

Contains electronic manual

Software installation program

原子吸收光谱仪(六灯位,火焰法)