One Box production: |
1 |
The shell is made of high-quality SECC steel plate and baked paint processed by CNC machine tools. The surface of the shell is treated with spray coating, making it more smooth and beautiful; The inner liner is made of imported high-quality SUS304 stainless steel plate; |
2 |
The insulation material is high-density glass fiber cotton with a thickness of 80mm; |
3 |
The mixing system adopts a long axis fan motor and a stainless steel multi blade impeller that is resistant to high and low temperatures to achieve strong convection and vertical diffusion circulation; |
4 |
Double layer high tensile sealing strips with high temperature resistance are used between the door and the box to ensure the sealing of the testing area; Using non reactive door handles makes operation easier; |
5 |
And high-quality fixed PU movable wheels are installed at the bottom of the machine, which can easily move the machine to the designated position and finally fix the casters; |
6 |
Install a set of visual observation windows at a reasonable position on the door of the equipment. The observation windows are made of multi-layer insulated tempered glass, which can clearly observe the test process. |
2、 Main functions |
The xenon lamp weather resistance test chamber has the following functions: |
1 |
Full spectrum xenon lamp; |
2 |
Multiple filtering systems to choose from; |
3 |
Solar irradiance control |
4 |
Water spray function |
5 |
Relative humidity control |
6 |
Blackboard/or test chamber air temperature control system |
7 |
Test methods that meet the requirements |
8 |
Irregular shaped fixed bracket |
9 |
Reasonably priced and replaceable xenon lamp tube |
3、 Detailed specifications |
1 |
Model: HSN-500A |
2 |
Studio size: D500mm * W760mm * H500mm |
3 |
Machine full size: D1200mm * W1140mm * H1490mm |
4 |
Sample tray size: 450 * 720mm |
5 |
Temperature range: adjustable from 40 ℃ to 80 ℃
|
6 |
Humidity range: 50% to 90% R • H adjustable |
7 |
Blackboard temperature: 63 ℃, 100 ℃± 3 ℃ |
8 |
Temperature fluctuation: ± 0.5 ℃ |
9 |
Temperature deviation: ± 2.0 ℃ |
10 |
Glass window filter: 4 pieces(1 spare), the average irradiation intensity transmitted through the three filters is 550W/㎡
|
11 |
Xenon lamp source: imported air-cooled lamp tube |
12 |
Xenon lamp quantity: 4 (1 spare) American Q-PANEL lamp tube |
13 |
Lamp lifespan: 1600 hours |
14 |
Rainfall duration: 0-9999 minutes, adjustable for continuous rainfall |
15 |
Rainfall cycle: 0-240min, adjustable interval (intermittent) rainfall |
16 |
Spray cycle (spray time/no spray time): 18min/102min or 12min/48min |
17 |
Rainwater pressure: 0.12-0.15Mpa |
18 |
Spray nozzle aperture: Ø 0.8mm |
19 |
Xenon lamp power: 1.8 KW per lamp |
20 |
Heating power: 3KW |
21 |
Humidification power: 1.5KW |
22 |
Distance between sample holder and lamp: 230-280mm |
23 |
Wavelength: 290-800nm |
24 |
The light cycle is continuously adjustable, with a time range of 1 to 999h, m, s |
25 |
Irradiance: The average irradiance between 290nm and 800nm wavelengths is 550W/㎡ |
26 |
Machine weight:About 600 tons
|
4、 Circuit control system |
Explanation: This xenon lamp weather resistance test chamber has multiple cycle programs, blackboard temperature, and test chamber air temperature and humidity to choose from, and is used for programming to simulate different usage environments. The exposure function and temperature are controlled by a thin film button type intelligent temperature controller with microcomputer automatic calculation and PID self-tuning function, which is easy and fast to operate. Time can be divided into total time, lighting time, spraying and stopping time, which are set separately. After the setting is completed, the equipment will automatically run according to the input program. The light irradiance display will display the current light irradiance intensity at any time. During the experiment, if any abnormalities occur or after the experiment is completed, the equipment will immediately sound an alarm and automatically terminate the experiment. |
1 |
The temperature and humidity control instrument adopts a fully imported high-precision digital display microcomputer integrated controller from South Korea |
2 |
Accuracy: 0.1 ℃ (display range) |
3 |
Resolution: ± 0.1 ℃ |
4 |
Temperature sensor: PT100 platinum resistance thermometer |
5 |
Control mode: Thermal balance temperature and humidity control mode |
6 |
All electrical appliances use Schneider series products |
7 |
Temperature and humidity control is achieved through coordinated control of the same channel using the P.I.D+S.S.R system |
8 |
Equipped with automatic calculation function, it can immediately correct the temperature and humidity change conditions, making temperature and humidity control more accurate and stable |
5、 Control of refrigeration and dehumidification systems |
1 |
Compressor: Fully enclosed, imported from France with original packaging "Taikang"; |
2 |
Refrigeration method: mechanical single machine refrigeration |
3 |
Condensation method: air-cooled |
4 |
Refrigerant: R404A (environmentally friendly) |
5 |
The entire system pipeline undergoes a 48 hour leak detection test with ventilation and pressurization |
6 |
The heating and cooling systems are completely independent |
7 |
Internal spiral refrigerant copper tube |
8 |
Fin slope evaporator (with automatic defrosting system) |
9 |
The dry filter, refrigerant flow window, repair valve, oil separator, solenoid valve, and storage tank are all imported original parts |
10 |
Dehumidification system: using evaporator coil dew point temperature laminar contact dehumidification method |
6、 Protection system |
1 |
Fan overheat protection |
2 |
Overall equipment under phase/reverse phase protection |
3 |
Overload protection for refrigeration system |
4 |
Refrigeration system overpressure protection |
5 |
overtemperature protection |
6 |
Overheating of water pump, overcurrent protection |
7 |
Other issues include electrical leakage |
8 |
water shortage indication |
9 |
Automatic shutdown after fault alarm |
7、 Random data |
1 |
Certificate of conformity, warranty card |
2 |
Instructions: Operating methods, precautions, basic shipping accessories, maintenance and repair matters |
8、 Equipment usage conditions |
1 |
Environmental temperature: 5 ℃~+28 ℃ (average temperature within 24 hours ≤ 28 ℃) |
2 |
Environmental humidity: ≤ 85% |
3 |
Power requirement: AC380 (± 10%) V/50HZ three-phase four wire system |
4 |
Pre installed capacity: 11KW |
9、 Applicable standards |
This product complies withGB/T16422.2-1999, DIN75220, ASTMG155, ISO10SB02/B04, SAEJ2527, SAEJ2421Waiting for standards. |