E-mail
hzjoule@163.com
-
Phone
19012707638
-
Address
No. 598 Hejing Road, Hezhuang Street, Qiantang District, Hangzhou City, Zhejiang Province
Hangzhou Joule Intelligent Technology Co., Ltd
hzjoule@163.com
19012707638
No. 598 Hejing Road, Hezhuang Street, Qiantang District, Hangzhou City, Zhejiang Province
Adiabatic calorimeterIntroduction
Adiabatic accelerated calorimeter is an analytical instrument designed to evaluate the thermal stability and potential reaction hazards of chemical substances under adiabatic conditions. This instrument accelerates the exothermic reaction process inside the sample by precisely controlling the sample environment, isolating external heat exchange, simulating temperature changes under storage or transportation conditions. The adiabatic acceleration calorimeter can monitor and record key parameters such as temperature and pressure of the sample in real-time during the reaction process, providing important safety assessment data for the research and development, production, storage, and transportation of chemicals. Its high-precision sensors and excellent measurement control and data processing system ensure the accuracy and reliability of test results, making it an indispensable safety assessment tool in fields such as chemical, pharmaceutical, and energy.
Adiabatic calorimeterTest Standard
SN/T 3078.1-2012、NY/T 3784-2020、ASTM1981-98(2020)……
Product Specifications
Product Model |
ARC Athena |
Container diameter mm |
90 |
Container depth mm |
110 |
Furnace body material |
CuCrZr |
Technical Specifications
parameter |
value |
Temperature control range |
Room temperature~600 ℃ |
Temperature control mode |
Heating Wait Search (HWS) mode, enhanced HWS mode, constant temperature Mode, isokinetic scanning mode, etc |
Temperature display resolution |
0.001℃ |
temperature stability |
0.01℃/min |
Temperature detection threshold |
0.005~0.02℃/min |
Temperature tracking rate |
0.005℃/min-40℃/min |
Maximum withstand voltage |
20MPa |
Pressure resolution |
1kPa |
Sample pool material |
Stainless steel, titanium alloy, Hastelloy alloy |
Phi值 |
≤1.35 |
interface |
RJ45 |
power |
≤3000W |
Optional features
function |
Brand/Model |
parameter |
Mixing function |
/ |
Mixing rate greater than 100rpm |
Low temperature module |
/ |
Liquid nitrogen purge refrigeration |
Product Features
Accurately simulate adiabatic conditions to ensure the authenticity of test results.
High precision sensors capture subtle changes in heat and provide reliable data.
Equipped with heat dissipation correction function, making the calculation of heat generation at the moment of explosion more accurate. The temperature measurement and control range is wide, which can meet the testing needs of different samples.
Real time monitoring of multiple parameters to fully understand the reaction status of the sample.
Chemical safety assessment effectively prevents the risk of production accidents.
Installation requirements
power supply |
AC220V/50Hz |
Venue requirements |
Inside the fume hood |
Environmental Requirements |
The equipment should be placed horizontally in a well ventilated laboratory, with sufficient space around for operation and maintenance. Temperature: (5-40) ℃, humidity:<85% RH |
environmental requirements |
During the experiment, smoke will be generated. It is recommended to install a smoke collection hood and exhaust duct above the equipment to solve the problem of smoke emissions |