8-channel fully automatic liquid separator CYFY-8 is suitable for multiple versions Main features:
1. The equipment adopts a precision peristaltic pump for non-contact liquid separation, and the whole machine is exquisite and compact, which can be placed in a super clean table for use.
2. Adopting a 7-inch color LCD touch screen, the operation is simple, and the liquid separation methods include quantitative separation and non quantitative separation. You can choose to add liquid to the whole board or any column.
3. The separation accuracy is high, with an error of less than 1.5% for a 96 well plate of 100 μ L. The minimum separation volume is as low as 5 µ L, and the addition time for a 96 well plate of 100 µ L is 12 seconds.
4. The separation strength can be adjusted in two levels, high and low, suitable for different experimental needs.
5. The movable waste liquid tank facilitates the discharge of waste liquid, and the bottom of the waste liquid tank can be connected to a pipeline to automatically recover waste liquid into the waste liquid bottle.
6. After separation, it can perform functions such as oscillation, pullback, and rinsing.
7. Applicable plate types: 96 well plate, 48 well plate, 384 plate, eight tube PCR tube, 96 PCR plate, enzyme-linked immunosorbent assay plate, various test tubes, centrifuge tubes, EP tubes (compatible with corresponding adapter racks)
8-channel fully automatic liquid separator CYFY-8 is suitable for various types of technical parameters:
1Model: CYFY-8
2Applicable version: 96 hole plate (standard)
3Separation method: Whole board or any column, column separation volume can be set
4Liquid separation speed: adjustable in two levels of "high low"
5Liquid separation volume: 1-2000 µ l (can be customized according to customer requirements)
6Liquid distribution pipeline: 8 channels
7Display mode: 7-inch LCD touch screen
8Liquid separation accuracy: 100 µ l ≤ 1.5% (96 well plate)
9Cleaning function: automatic lubrication and suction function
10Auxiliary functions: oscillation, return function
11Compatible container: customizable according to needs
12Working temperature: -20 ℃ -40 ℃
13Relative humidity:<80%
14Liquid requirements:Can be packaged in barrels or bottles
15Suitable container:On-demand customization
Working principle and precautions of the liquid analyzer
The working principle of a liquid separator is simple, as it utilizes the incompatibility and gravity of liquids. The liquid in the separator will be divided into two phases that are separated from each other due to their different densities and strong incompatibility. As a result, they will naturally stratify, with the organic phase on top and the aqueous phase on the bottom. When it is necessary to separate two phases, the liquid is usually injected into the separator through a funnel, and then after the two phases separate, the bottom valve is opened to release the bottom water phase from the container. After the water phase is completely drained, close the valve and use a dry filter paper (or calcium chloride)
Precautions
(1) Maintenance and upkeep
Please regularly check the wear condition of the pump tube, and replace it promptly if any abnormalities or damages are found. Before long-term storage, the equipment needs to be cleaned and the pump tube removed. During storage, attention should be paid to moisture prevention.
1. Regularly check whether the connections of each component of the machine are tightened to ensure that the machine will not be damaged due to looseness during operation.
2. Regularly clean the residue inside the machine, keep it clean, and prevent corrosion.
3. Maintain appropriate temperature and humidity in the laboratory, avoiding environments that are too cold, too hot, or too humid, which may affect the stable operation of the instruments.
4. Regularly calibrate instruments to ensure the accuracy of measurement results.
5. Keep the instrument dry, especially during operation, pay attention to timely closing the system valves to prevent liquid leakage.
6. Regularly update software programs to ensure excellent performance and operation of the instrument.
7. Do not disassemble or modify the instrument at will. If maintenance is required, please contact professional personnel for operation.
During use, if any abnormalities are found, the operation should be stopped immediately and relevant personnel should be contacted.
(2) Liquid volume calibration
The calibration of the equipment needs to be carried out in conjunction with an analytical balance. The actual liquid output is converted into volume by weighing and compared with the set value of the equipment for verification. The liquid output is adjusted by adjusting the ratchet buckle on the peristaltic pump head. Pulling the ratchet buckle upwards reduces the fluid output, while pulling it downwards increases the fluid output. The separation accuracy can reach within 1.5% of 100 μ l error on a 96 well plate, with a minimum separation volume as low as 5 µ L. The addition time for 100 µ L on a 96 well plate is 10 seconds.
What is the maintenance cycle for an 8-channel liquid separator
As a precise and efficient automated liquid separation equipment in the laboratory, the maintenance cycle of the 8-channel liquid separator is crucial for ensuring the long-term stable operation of the instrument. Generally speaking, the maintenance cycle of an 8-channel liquid separator varies depending on its frequency of use, working environment, and specific model.
Under normal usage conditions, it is recommended to conduct comprehensive maintenance every six months to one year to ensure the instrument's liquid separation accuracy, smooth operation, and overall performance. The maintenance content mainly includes the following aspects:
Firstly, it is necessary to inspect the mechanical components of the instrument, such as the peristaltic pump, robotic arm, and separation pipeline, to check for wear or looseness, and replace the worn parts in a timely manner;
Secondly, check and clean the display screen, buttons, and casing of the instrument to prevent dust and liquid residue from causing damage to the instrument;
At the same time, it is necessary to perform dust removal and testing on the internal circuit board and sensors of the instrument to ensure their normal operation;
Finally, calibrate the instrument and use an analytical balance to verify the accuracy of liquid separation by measuring the actual liquid output. Adjust the ratchet buckle on the peristaltic pump head to achieve excellent liquid separation effect.
It is worth noting that in special usage environments such as high humidity, high temperature, or frequently used laboratories, maintenance cycles may need to be shortened to cope with more demanding working conditions.
In addition, regular software updates and upgrades are also important means to maintain instrument performance and stability.
In summary, a reasonable maintenance cycle and meticulous maintenance measures can extend the service life of the 8-channel liquid separator and improve experiments
Efficiency and ensuring the accuracy of experimental data are of great significance.
Laboratory personnel should develop a scientific maintenance plan based on actual conditions and strictly implement it to ensure the long-term stable operation of the instruments.