- Phone
-
Address
Room 121, Building 2, No. 655 Gaoji Road, Sijing Town, Songjiang District, Shanghai
Shanghai Tingheng Weighing Instrument Co., Ltd
Room 121, Building 2, No. 655 Gaoji Road, Sijing Town, Songjiang District, Shanghai
1mg-200g E2 grade JF-1 non-magnetic stainless steel weightWeight selector for laboratory and precision scales
Weight grade:E1 E2 F1 F2 M1 M2
Weight material:JF-1 non-magnetic stainless steel standard weight non-magnetic stainless steel standard weight stainless steel standard weight steel chrome plated standard weight cast iron standard weight
E2 high-grade weight material magnetic susceptibility ≤ 0.0006
material density=8.00g/cm3
polarization intensity:E1≤2.5μT; E2≤8μT; F1≤25μT
Packaging: Aluminum alloy boxRound plastic box
The accuracy of conventional testing scales is the core work of most quality systems.M1 weight selector is recommended to use CarePac ®, This includes two appropriate weights for testing process tolerances up to 0.03%.
The recommended nominal value and weight category of this weight selector have been calculated for detecting specified process tolerances up to A balance of 0.03%. The smaller the process tolerance, the more accurate the weight category is required.


E1 grade stainless steel weights |
E2 grade stainless steel weights |
F1 grade stainless steel weights |
F2 grade stainless steel weight |
M1 grade stainless steel weight |
M1 grade steel chrome plated weight |
F1 level set weight specifications:
1mg~100g.1mg~200g.1mg~500g.1mg~1000g.1mg~2000g.1mg~5000g
F2 level single weight:
1mg.2mg.5mg.10mg.20mg.50mg.100mg.200mg.500mg.
1g.2g.5g.10g.20g.50g.10g.200g.500g.1000g.2000g.5000g.10kg.20kg
Milligram tablet weight:
1mg.2mg5mg.10mg.20mg.50mg.100mg.200mg.500mg
Multiple sets of weights with specific specifications:
suit |
1mg |
2 mg |
5 mg |
10 mg |
20 mg |
50 mg |
100 mg |
200 mg |
500 mg |
1g |
2 g |
5 g |
10 g |
20 g |
50 g |
100 g |
200 g |
500 g |
1kg |
2kg |
5kg |
quantity |
|
1mg~100g |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
0 |
0 |
0 |
0 |
0 |
21 |
|
1mg~200g |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
0 |
0 |
0 |
0 |
23 |
|
1mg~500g |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
0 |
0 |
0 |
24 |
|
1mg~1000g |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
0 |
0 |
25 |
|
1mg~2000g |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
0 |
27 |
|
1mg~5000g |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
1 |
2 |
1 |
28 |
|
Taboo actions to be noted during the use of 1mg-200gE2 grade JF-1 non-magnetic stainless steel weights.I hope it can be helpful to everyone.
attention1:hand-grab,This is in use,The most common mistake people make,But some people repeatedly make mistakes in their operations.
attention2:Do not wipe with a damp cloth.
attention3:Just leave it randomly,for convenience,Many people like to leave things haphazardly after using them up or adding or subtracting them,This is also a mistake that many people like to make.
attention4:Friction and collision with objects.
attention5:Lifting with plastic is also a precautionary measure,The surface of plastic is very smooth,Friction is not good enough,Easy to fall to the ground and cause damage.
Disclaimer for weight selectors used in laboratories and precision scales
The suggestions regarding the routine testing of scales using weights are for reference onlyIt does not have any binding force.
To achieve the highest weighing accuracy and optimize the use of weighing instrumentsRegular and timely calibration and testing must be carried out. The weight recommendation aims to improve weighing accuracy and optimize the use of weighing instruments.
Equipment users must determine their calibration and testing procedures based on their own discretion and at their own riskEspecially the process tolerance. Therefore, it is necessary to consider the specific characteristics of the activity field and regulatory requirements. The device user is ultimately responsible for determining the testing procedure and applicable process tolerances