1mg-200g E2 grade JF-1 non-magnetic stainless steel weight

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The 1mg-200gE2 grade JF-1 non-magnetic stainless steel weight is a physical measuring tool with a given mass and specified shape. Used for calibrating scales and measuring on scales. Weights must be combined with a balance or scale (weights used on scales are often referred to as weights) in order to be used to determine the mass of other objects, so it is a subordinate physical measuring tool.

Product Details

1mg-200g E2 grade JF-1 non-magnetic stainless steel weightWeight selector for laboratory and precision scales

Weight grade:E1 E2 F1 F2 M1 M2

Weight material:JF-1 non-magnetic stainless steel standard weight non-magnetic stainless steel standard weight stainless steel standard weight steel chrome plated standard weight cast iron standard weight

E2 high-grade weight material magnetic susceptibility ≤ 0.0006

material density=8.00g/cm3

polarization intensity:E1≤2.5μT; E2≤8μT; F1≤25μT

Packaging: Aluminum alloy boxRound plastic box

The accuracy of conventional testing scales is the core work of most quality systems.M1 weight selector is recommended to use CarePac ®, This includes two appropriate weights for testing process tolerances up to 0.03%.

The recommended nominal value and weight category of this weight selector have been calculated for detecting specified process tolerances up to A balance of 0.03%. The smaller the process tolerance, the more accurate the weight category is required.



E1 grade stainless steel weights

E2 grade stainless steel weights

F1 grade stainless steel weights

F2 grade stainless steel weight

M1 grade stainless steel weight

M1 grade steel chrome plated weight

F1 level set weight specifications:

1mg~100g.1mg~200g.1mg~500g.1mg~1000g.1mg~2000g.1mg~5000g

F2 level single weight:

1mg.2mg.5mg.10mg.20mg.50mg.100mg.200mg.500mg.

1g.2g.5g.10g.20g.50g.10g.200g.500g.1000g.2000g.5000g.10kg.20kg

Milligram tablet weight:

1mg.2mg5mg.10mg.20mg.50mg.100mg.200mg.500mg

Multiple sets of weights with specific specifications:

suit

1mg

2 mg

5 mg

10 mg

20 mg

50 mg

100 mg

200 mg

500 mg

1g

2 g

5 g

10 g

20 g

50 g

100 g

200 g

500 g

1kg

2kg

5kg

quantity

1mg~100g

1

2

1

1

2

1

1

2

1

1

2

1

1

2

1

1

0

0

0

0

0

21

1mg~200g

1

2

1

1

2

1

1

2

1

1

2

1

1

2

1

1

2

0

0

0

0

23

1mg~500g

1

2

1

1

2

1

1

2

1

1

2

1

1

2

1

1

2

1

0

0

0

24

1mg~1000g

1

2

1

1

2

1

1

2

1

1

2

1

1

2

1

1

2

1

1

0

0

25

1mg~2000g

1

2

1

1

2

1

1

2

1

1

2

1

1

2

1

1

2

1

1

2

0

27

1mg~5000g

1

2

1

1

2

1

1

2

1

1

2

1

1

2

1

1

2

1

1

2

1

28

Taboo actions to be noted during the use of 1mg-200gE2 grade JF-1 non-magnetic stainless steel weights.I hope it can be helpful to everyone.

attention1:hand-grab,This is in use,The most common mistake people make,But some people repeatedly make mistakes in their operations.

attention2:Do not wipe with a damp cloth.

attention3:Just leave it randomly,for convenience,Many people like to leave things haphazardly after using them up or adding or subtracting them,This is also a mistake that many people like to make.

attention4:Friction and collision with objects.

attention5:Lifting with plastic is also a precautionary measure,The surface of plastic is very smooth,Friction is not good enough,Easy to fall to the ground and cause damage.


Disclaimer for weight selectors used in laboratories and precision scales

The suggestions regarding the routine testing of scales using weights are for reference onlyIt does not have any binding force.

To achieve the highest weighing accuracy and optimize the use of weighing instrumentsRegular and timely calibration and testing must be carried out. The weight recommendation aims to improve weighing accuracy and optimize the use of weighing instruments.

Equipment users must determine their calibration and testing procedures based on their own discretion and at their own riskEspecially the process tolerance. Therefore, it is necessary to consider the specific characteristics of the activity field and regulatory requirements. The device user is ultimately responsible for determining the testing procedure and applicable process tolerances