| Product features |
| Total number of inputs and outputs |
Number of digital outputs: 2; Analog output quantity: 1 |
| measurement range |
| 0.1...25 l/min |
0.005...1.5 m³/h |
|
| system interface |
Threaded connection G 1/2 DN15 flat seal |
| application |
| Special performance |
Gold plated contacts |
| application |
Adder function; For industrial applications |
| Install |
Connect the pipeline through an adapter |
| medium |
Conductive liquid; Water; Water is the basic medium |
| Media Description |
| Conductivity: ≥ 20 µ S/cm |
| Viscosity:<70 mm ²/s (40 ° C) |
|
| Medium temperature [° C] |
-10...70 |
| Compressive strength [bar] |
16 |
| Compressive strength [Mpa] |
1.6 |
| Maximum allowable work pressure (for applications that comply with CRN standards) [bar] |
17.7 |
| Electrical data |
| Working voltage [V] |
18... 30 DC; (compliant with EN 50178 SELV/PELV standard) |
| Current loss [mA] |
95; (24 V) |
| Insulation resistance small value [M Ω] |
100; (500 V DC) |
| Protection level |
III |
| Reverse phase protection |
have |
| Startup delay time [s] |
5 |
| Overall input/output |
| Total number of inputs and outputs |
Number of digital outputs: 2; Analog output quantity: 1 |
| input |
| input |
Counter reset |
| output |
| Output quantity |
2 |
| output signal |
Switch signal; Analog signal; Pulse signal; IO-Link; (configurable) |
| Electrical Design |
PNP/NPN |
| Number of digital outputs |
2 |
| output function |
Normally open/normally closed; (Parameters can be set) |
| Switching output DC voltage drop large value [V] |
2 |
| Continuous current load of switch output DC [mA] |
200 |
| Simulated output quantity |
1 |
| Analog current output [mA] |
4...20; (Adjustable range) |
| Load maximum value [Ω] |
500 |
| Analog voltage output [V] |
0...10; (Adjustable range) |
| Load resistance small value [Ω] |
2000 |
| pulse output |
flow meter |
| short circuit protection |
have |
| Short circuit protection type |
pulse |
| overload protection |
have |
| Measurement/Setting Range |
| measurement range |
| 0.1...25 l/min |
0.005...1.5 m³/h |
|
| display range |
| -30...30 l/min |
-1.8...1.8 m³/h |
|
| resolution |
|
| Switch point, SP |
| 0.25...25 l/min |
0.015...1.5 m³/h |
|
| Recovery point, rP |
| 0.1...24.9 l/min |
0.005...1.495 m³/h |
|
| Measurement starting point, ASP |
| 0...20 l/min |
0...1.2 m³/h |
|
| Measurement endpoint, AEP |
| 5...25 l/min |
0.3...1.5 m³/h |
|
| step distance |
|
| traffic monitoring |
| pulse value |
0.00001...30 000 m³ |
| Pulse length [s] |
0,01...2 |
| Temperature monitoring |
| Measurement range [° C] |
-20...80 |
| Resolution [° C] |
0.2 |
| Switch point, SP [° C] |
-19.2...80 |
| Recovery point, rP [° C] |
-19.6...79.6 |
| Measurement starting point [° C] |
-20...60 |
| Measurement endpoint [° C] |
0...80 |
| Set step distance [° C] |
0.2 |
| Accuracy/Deviation |
| traffic monitoring |
| Degree (within the measurement range) |
± (0,8 % MW + 0,5 % MEW) |
| repeatability accuracy |
± 0,2% MEW |
| Temperature monitoring |
| 度 [K] |
± 2,5 (Q > 1 l/min) |
| reaction time |
| traffic monitoring |
| Reaction time [s] |
0.15; (dAP = 0, T19) |
| Programmable delay time dS, dr [s] |
0...50 |
| Damping dAP [s] for switch output |
0...5 |
| Temperature monitoring |
| Response time T05/T09 [s] |
T09 = 20 (Q > 1 l/min) |
| Software/Programming |
| Parameter Settings |
Traffic monitoring; Quantity calculation; Pre-set capacity meter; Temperature monitoring; Delay/Window; Normally open/normally closed; Output polarity; Current/voltage/pulse output; Start delay; Display can be turned off; display unit |
| interface |
| communication interface |
IO-Link |
| Transfer type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| appearance |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
| SIO mode |
have |
| Required Material Port Type |
A |
| Simulated process data |
3 |
| Two digit output process data |
2 |
| Processing cycle small value [ms] |
5 |
| Supported DeviceIDs |
| Operation mode |
Deviceid |
| default |
569 |
|
| working conditions |
| Environmental temperature [° C] |
-10...60 |
| Storage temperature [° C] |
-25...80 |
| Shell protection level |
IP 67 |
| Certification/Testing |
| EMC Electromagnetic Compatibility |
|
| impact-resistant |
| DIN IEC 68-2-27 |
20 g (11 ms) |
|
| earthquake resistance |
| DIN IEC 68-2-6 |
5 g (10...2000 Hz) |
|
| MTTF [year] |
162 |
| Pressure Equipment Directive |
Good engineering practices; Can be used for Group 2 fluids; According to the fluid requirements of fluid group 1 |
| Mechanical technical data |
| Weight [g] |
542.5 |
| raw materials |
Stainless steel (1.4404/316L); PBT-GF20; PC; FKM; TPE |
| Materials (wet parts) |
Stainless steel (1.4404/316L); PEEK; FKM |
| system interface |
Threaded connection G 1/2 DN15 flat seal |
| Display/operating components |
| display |
| display unit |
6 x LED, Green (l/min, m ³/h, l, m ³, 10 ³, ° C) |
| switch status |
2 x LED, yellow |
| measured value |
Alphanumeric display, 4-digit number |
| programming |
Alphanumeric display, 4-digit number |
|
| annotation |
| annotation |
| MW=measured value |
| MEW = Final value of the measuring range |
|
| packaging unit |
1 piece |
| electrical connection |
| interface |
Connector: 1 x M12; Contact: gold-plated |