Welcome Customer !

Membership

Help

Shanghai Yibo Electromechanical Equipment Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products
Product Categories

Shanghai Yibo Electromechanical Equipment Co., Ltd

  • E-mail

  • Phone

  • Address

    No. 182 Anbian Road, Putuo District, Shanghai

Contact Now

*Yifumen IFM pressure sensor SM6000

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

*Yifumen IFM Pressure Sensor SM6000 Product Introduction: Two switch outputs, one of which can be programmed as IO Link and the other can be used as an analog output

Product Details

*Yifumen IFM pressure sensor SM6000Product Details

*Yifumen IFM pressure sensor SM6000

Product features
Total number of inputs and outputs Number of digital outputs: 2; Analog output quantity: 1
measurement range
0.1...25 l/min 0.005...1.5 m³/h
system interface Threaded connection G 1/2 DN15 flat seal
application
Special performance Gold plated contacts
application Adder function; For industrial applications
Install Connect the pipeline through an adapter
medium Conductive liquid; Water; Water is the basic medium
Media Description
Conductivity: ≥ 20 µ S/cm
Viscosity:<70 mm ²/s (40 ° C)
Medium temperature [° C] -10...70
Compressive strength [bar] 16
Compressive strength [Mpa] 1.6
Maximum allowable work pressure (for applications that comply with CRN standards) [bar] 17.7
Electrical data
Working voltage [V] 18... 30 DC; (compliant with EN 50178 SELV/PELV standard)
Current loss [mA] 95; (24 V)
Insulation resistance small value [M Ω] 100; (500 V DC)
Protection level III
Reverse phase protection have
Startup delay time [s] 5
Overall input/output
Total number of inputs and outputs Number of digital outputs: 2; Analog output quantity: 1
input
input Counter reset
output
Output quantity 2
output signal Switch signal; Analog signal; Pulse signal; IO-Link; (configurable)
Electrical Design PNP/NPN
Number of digital outputs 2
output function Normally open/normally closed; (Parameters can be set)
Switching output DC voltage drop large value [V] 2
Continuous current load of switch output DC [mA] 200
Simulated output quantity 1
Analog current output [mA] 4...20; (Adjustable range)
Load maximum value [Ω] 500
Analog voltage output [V] 0...10; (Adjustable range)
Load resistance small value [Ω] 2000
pulse output flow meter
short circuit protection have
Short circuit protection type pulse
overload protection have
Measurement/Setting Range
measurement range
0.1...25 l/min 0.005...1.5 m³/h
display range
-30...30 l/min -1.8...1.8 m³/h
resolution
0.02 l/min 0.002 m³/h
Switch point, SP
0.25...25 l/min 0.015...1.5 m³/h
Recovery point, rP
0.1...24.9 l/min 0.005...1.495 m³/h
Measurement starting point, ASP
0...20 l/min 0...1.2 m³/h
Measurement endpoint, AEP
5...25 l/min 0.3...1.5 m³/h
step distance
0.02 l/min 0.002 m³/h
traffic monitoring
pulse value 0.00001...30 000 m³
Pulse length [s] 0,01...2
Temperature monitoring
Measurement range [° C] -20...80
Resolution [° C] 0.2
Switch point, SP [° C] -19.2...80
Recovery point, rP [° C] -19.6...79.6
Measurement starting point [° C] -20...60
Measurement endpoint [° C] 0...80
Set step distance [° C] 0.2
Accuracy/Deviation
traffic monitoring
Degree (within the measurement range) ± (0,8 % MW + 0,5 % MEW)
repeatability accuracy ± 0,2% MEW
Temperature monitoring
度 [K] ± 2,5 (Q > 1 l/min)
reaction time
traffic monitoring
Reaction time [s] 0.15; (dAP = 0, T19)
Programmable delay time dS, dr [s] 0...50
Damping dAP [s] for switch output 0...5
Temperature monitoring
Response time T05/T09 [s] T09 = 20 (Q > 1 l/min)
Software/Programming
Parameter Settings Traffic monitoring; Quantity calculation; Pre-set capacity meter; Temperature monitoring; Delay/Window; Normally open/normally closed; Output polarity; Current/voltage/pulse output; Start delay; Display can be turned off; display unit
interface
communication interface IO-Link
Transfer type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
appearance Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode have
Required Material Port Type A
Simulated process data 3
Two digit output process data 2
Processing cycle small value [ms] 5
Supported DeviceIDs
Operation mode Deviceid
default 569
working conditions
Environmental temperature [° C] -10...60
Storage temperature [° C] -25...80
Shell protection level IP 67
Certification/Testing
EMC Electromagnetic Compatibility
DIN EN 60947-5-9
impact-resistant
DIN IEC 68-2-27 20 g (11 ms)
earthquake resistance
DIN IEC 68-2-6 5 g (10...2000 Hz)
MTTF [year] 162
Pressure Equipment Directive Good engineering practices; Can be used for Group 2 fluids; According to the fluid requirements of fluid group 1
Mechanical technical data
Weight [g] 542.5
raw materials Stainless steel (1.4404/316L); PBT-GF20; PC; FKM; TPE
Materials (wet parts) Stainless steel (1.4404/316L); PEEK; FKM
system interface Threaded connection G 1/2 DN15 flat seal
Display/operating components
display
display unit 6 x LED, Green (l/min, m ³/h, l, m ³, 10 ³, ° C)
switch status 2 x LED, yellow
measured value Alphanumeric display, 4-digit number
programming Alphanumeric display, 4-digit number
annotation
annotation
MW=measured value
MEW = Final value of the measuring range
packaging unit 1 piece
electrical connection
interface Connector: 1 x M12; Contact: gold-plated