*Yifumen IFM pressure sensor PN3070

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

*Yifumen IFM Pressure Sensor PN3070 Product Introduction: Two switch outputs, one of which can be programmed as IO Link and the other can be used as an analog output with red/green display to clearly indicate the acceptable range

Product Details

*Yifumen IFM pressure sensor PN3070Product Details

*Yifumen IFM pressure sensor PN3070

  • Two switch outputs, one programmable as IO Link and the other as an analog output
  • Red/green display, used to clearly indicate the acceptable range
  • The pipeline connection can be rotated for easy arrangement
  • High load protection, long-term stability
  • Durable design, suitable for harsh industrial environments
    Product features
    output signal Switch signal; Analog signal; IO-Link; (configurable)
    measurement range
    0...400 bar 0...5800 psi 0...40 MPa
    system interface Threaded connection G 1/4 internal thread M6 I
    application
    Special performance Gold plated contacts
    Measuring components metal diaphragm
    application For industrial applications
    medium Liquid and gas media
    Medium temperature [° C] -25...80
    Small value of blasting pressure
    1700 bar 24650 psi 170 MPa
    compressive strength
    800 bar 11580 psi 80 Mpa
    Vacuum resistance [mbar] -1000
    pressure relative pressure
    Electrical data
    Working voltage [V] 18... 30 DC; (compliant with EN 50178 SELV/PELV standard)
    Current loss [mA] < 35
    Insulation resistance small value [M Ω] 100; (500 V DC)
    protection level III
    Reverse phase protection have
    Startup delay time [s] < 0.3
    Watchdog Integrated Watchdog Circuit have
    Overall input/output
    Total number of inputs and outputs Number of digital outputs: 1; Analog output quantity: 1
    output
    output quantity 2
    output signal Switch signal; Analog signal; IO-Link; (configurable)
    Electrical Design PNP
    Number of digital outputs 1
    Output function Normally open/normally closed; (Parameters can be set)
    Switching output DC voltage drop large value [V] 2.5
    Continuous current load of switch output DC [mA] 150; (200 (...60 °C) 250 (...40 °C))
    Switching frequency DC [Hz] < 170
    Simulated output quantity 1
    Analog current output [mA] 4...20
    Load maximum value [Ω] 500
    Analog voltage output [V] 0...10
    Load resistance small value [Ω] 2000
    short circuit protection have
    Short circuit protection type pulse
    overload protection have
    Measurement/Setting Range
    measurement range
    0...400 bar 0...5800 psi 0...40 MPa
    Factory setting / CMPT = 2
    Switch point, SP
    4...400 bar 40...5800 psi 0.4...40 MPa
    Recovery point, rP
    2...398 bar 20...5780 psi 0.2...39.8 MPa
    Small distance between SP and rP
    2 bar 40 psi 0.2 MPa
    Set step distance
    2 bar 20 psi 0.2 MPa
    Status_B High Resolution / CMPT = 3
    Switch point, SP
    3...400 bar 49...5802 psi 0.3...40 MPa
    Recovery point, rP
    1...398 bar 20...5773 psi 0.1...39.8 MPa
    Small distance between SP and rP
    2 bar 30 psi 0.2 MPa
    Set step distance
    1 bar 1 psi 0.1 MPa
    Accuracy/Deviation
    Switch point accuracy [% of measurement range value] < ± 0,5
    Repetitive accuracy [% of measurement range value] < ± 0,1; (Temperature fluctuation<10 K)
    Characteristic curve deviation [% of measurement range value] < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL=Best Fit Straight Line; LS=Limit Point Setting)
    Lag deviation [% of measurement range value] < ± 0,25
    Long term stability [% of measurement range value] < ± 0,05; (Every 6 months)
    Temperature coefficient zero point [percentage of measurement range value/10 K] 0,2; (-25...80 °C)
    Temperature coefficient range [percentage of measurement range value/10 K] 0,2; (-25...80 °C)
    reaction time
    Reaction time [ms] < 3
    Programmable delay time dS, dr [s] 0...50
    Damping dAP [s] for switch output 0...4
    Damping for analog output (dAA) [s] 0...4
    Simulated output response time large value [ms] 3
    Software/Programming
    Parameter Settings Delay/Window; Normally open/normally closed; ON delay, turn off delay; Damping; Display unit; Current/voltage output
    interface
    communication interface IO-Link
    Transfer type COM2 (38,4 kBaud)
    IO-Link revision 1.1
    SDCI standard IEC 61131-9
    SIO mode have
    Required Material Port Type A
    Simulated process data 1
    Two digit output process data 1
    Supported DeviceIDs
    Operation mode Deviceid
    Factory setting / CMPT = 2 427
    Status_B High Resolution / CMPT = 3 606
    annotation
    For more information, please refer to the IODD PDF file in the 'Download' section
    Factory setting / CMPT = 2
    appearance Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
    Processing cycle small value [ms] 2.3
    IO Link pressure resolution [bar] 1
    IO Link pressure resolution [MPa] 0.1
    IO Link process data (periodic)
    function Position length
    pressure 14
    Binary switch information 1
    IO Link function (non periodic) Apply specific tags
    Status_B High Resolution / CMPT = 3
    appearance Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
    Processing cycle small value [ms] 3
    IO Link pressure resolution [bar] 0.2
    IO Link pressure resolution [MPa] 0.02
    IO Link process data (periodic)
    function Position length
    pressure 16
    Device Status 4
    Binary switch information 1
    IO Link function (non periodic) Apply specific tags
    working conditions
    Environmental temperature [° C] -25...80
    Storage temperature [° C] -40...100
    Shell protection level IP 65; IP 67
    Certification/Testing
    EMC electromagnetic compatibility
    DIN EN 61000-6-2
    DIN EN 61000-6-3
    impact-resistant
    DIN EN 60068-2-27 50 g (11 ms)
    earthquake resistance
    DIN EN 60068-2-6 20 g (10...2000 Hz)
    MTTF [year] 190
    UL Certification
    UL certification number J006
    Pressure Equipment Directive Good engineering practices; Can be used for Group 2 fluids; According to the fluid requirements of fluid group 1
    Mechanical technical data
    Weight [g] 231.5
    raw materials 1.4542 (17-4 PH / 630); 不锈钢 (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
    Materials (wet parts) 1.4542 (17-4 PH / 630)
    Switch action lifespan 100 million
    Tightening torque [Nm] 25...35; (Recommended tightening torque; depends on lubrication, sealing, and pressure rating)
    system interface Threaded connection G 1/4 internal thread M6 I
    Integrated limiter component No (can be modified)
    Display/operating components
    display
    Display units 3 x LED, Green (bar, psi, MPa)
    switch status 1 x LED, yellow
    measured value Alphanumeric display, red/green 4-digit number
    annotation
    packaging unit 1 piece
    electrical connection
    interface Connector: 1 x M12; Contact: gold-plated