| Product features |
| output signal |
Switch signal; Analog signal; IO-Link; (configurable) |
| measurement range |
| 0...400 bar |
0...5800 psi |
0...40 MPa |
|
| system interface |
Threaded connection G 1/4 internal thread M6 I |
| application |
| Special performance |
Gold plated contacts |
| Measuring components |
metal diaphragm |
| application |
For industrial applications |
| medium |
Liquid and gas media |
| Medium temperature [° C] |
-25...80 |
| Small value of blasting pressure |
| 1700 bar |
24650 psi |
170 MPa |
|
| compressive strength |
|
| Vacuum resistance [mbar] |
-1000 |
| pressure |
relative pressure |
| Electrical data |
| Working voltage [V] |
18... 30 DC; (compliant with EN 50178 SELV/PELV standard) |
| Current loss [mA] |
< 35 |
| Insulation resistance small value [M Ω] |
100; (500 V DC) |
| protection level |
III |
| Reverse phase protection |
have |
| Startup delay time [s] |
< 0.3 |
| Watchdog Integrated Watchdog Circuit |
have |
| Overall input/output |
| Total number of inputs and outputs |
Number of digital outputs: 1; Analog output quantity: 1 |
| output |
| output quantity |
2 |
| output signal |
Switch signal; Analog signal; IO-Link; (configurable) |
| Electrical Design |
PNP |
| Number of digital outputs |
1 |
| Output function |
Normally open/normally closed; (Parameters can be set) |
| Switching output DC voltage drop large value [V] |
2.5 |
| Continuous current load of switch output DC [mA] |
150; (200 (...60 °C) 250 (...40 °C)) |
| Switching frequency DC [Hz] |
< 170 |
| Simulated output quantity |
1 |
| Analog current output [mA] |
4...20 |
| Load maximum value [Ω] |
500 |
| Analog voltage output [V] |
0...10 |
| Load resistance small value [Ω] |
2000 |
| short circuit protection |
have |
| Short circuit protection type |
pulse |
| overload protection |
have |
| Measurement/Setting Range |
| measurement range |
| 0...400 bar |
0...5800 psi |
0...40 MPa |
|
| Factory setting / CMPT = 2 |
| Switch point, SP |
| 4...400 bar |
40...5800 psi |
0.4...40 MPa |
|
| Recovery point, rP |
| 2...398 bar |
20...5780 psi |
0.2...39.8 MPa |
|
| Small distance between SP and rP |
|
| Set step distance |
|
| Status_B High Resolution / CMPT = 3 |
| Switch point, SP |
| 3...400 bar |
49...5802 psi |
0.3...40 MPa |
|
| Recovery point, rP |
| 1...398 bar |
20...5773 psi |
0.1...39.8 MPa |
|
| Small distance between SP and rP |
|
| Set step distance |
|
| Accuracy/Deviation |
| Switch point accuracy [% of measurement range value] |
< ± 0,5 |
| Repetitive accuracy [% of measurement range value] |
< ± 0,1; (Temperature fluctuation<10 K) |
| Characteristic curve deviation [% of measurement range value] |
< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL=Best Fit Straight Line; LS=Limit Point Setting) |
| Lag deviation [% of measurement range value] |
< ± 0,25 |
| Long term stability [% of measurement range value] |
< ± 0,05; (Every 6 months) |
| Temperature coefficient zero point [percentage of measurement range value/10 K] |
0,2; (-25...80 °C) |
| Temperature coefficient range [percentage of measurement range value/10 K] |
0,2; (-25...80 °C) |
| reaction time |
| Reaction time [ms] |
< 3 |
| Programmable delay time dS, dr [s] |
0...50 |
| Damping dAP [s] for switch output |
0...4 |
| Damping for analog output (dAA) [s] |
0...4 |
| Simulated output response time large value [ms] |
3 |
| Software/Programming |
| Parameter Settings |
Delay/Window; Normally open/normally closed; ON delay, turn off delay; Damping; Display unit; Current/voltage output |
| interface |
| communication interface |
IO-Link |
| Transfer type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| SIO mode |
have |
| Required Material Port Type |
A |
| Simulated process data |
1 |
| Two digit output process data |
1 |
| Supported DeviceIDs |
| Operation mode |
Deviceid |
| Factory setting / CMPT = 2 |
427 |
| Status_B High Resolution / CMPT = 3 |
606 |
|
| annotation |
| For more information, please refer to the IODD PDF file in the 'Download' section |
|
| Factory setting / CMPT = 2 |
| appearance |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
| Processing cycle small value [ms] |
2.3 |
| IO Link pressure resolution [bar] |
1 |
| IO Link pressure resolution [MPa] |
0.1 |
| IO Link process data (periodic) |
| function |
Position length |
| pressure |
14 |
| Binary switch information |
1 |
|
| IO Link function (non periodic) |
Apply specific tags |
| Status_B High Resolution / CMPT = 3 |
| appearance |
Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) |
| Processing cycle small value [ms] |
3 |
| IO Link pressure resolution [bar] |
0.2 |
| IO Link pressure resolution [MPa] |
0.02 |
| IO Link process data (periodic) |
| function |
Position length |
| pressure |
16 |
| Device Status |
4 |
| Binary switch information |
1 |
|
| IO Link function (non periodic) |
Apply specific tags |
| working conditions |
| Environmental temperature [° C] |
-25...80 |
| Storage temperature [° C] |
-40...100 |
| Shell protection level |
IP 65; IP 67 |
| Certification/Testing |
| EMC electromagnetic compatibility |
| DIN EN 61000-6-2 |
|
| DIN EN 61000-6-3 |
|
|
| impact-resistant |
| DIN EN 60068-2-27 |
50 g (11 ms) |
|
| earthquake resistance |
| DIN EN 60068-2-6 |
20 g (10...2000 Hz) |
|
| MTTF [year] |
190 |
| UL Certification |
| UL certification number |
J006 |
|
| Pressure Equipment Directive |
Good engineering practices; Can be used for Group 2 fluids; According to the fluid requirements of fluid group 1 |
| Mechanical technical data |
| Weight [g] |
231.5 |
| raw materials |
1.4542 (17-4 PH / 630); 不锈钢 (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC |
| Materials (wet parts) |
1.4542 (17-4 PH / 630) |
| Switch action lifespan |
100 million |
| Tightening torque [Nm] |
25...35; (Recommended tightening torque; depends on lubrication, sealing, and pressure rating) |
| system interface |
Threaded connection G 1/4 internal thread M6 I |
| Integrated limiter component |
No (can be modified) |
| Display/operating components |
| display |
| Display units |
3 x LED, Green (bar, psi, MPa) |
| switch status |
1 x LED, yellow |
| measured value |
Alphanumeric display, red/green 4-digit number |
|
| annotation |
| packaging unit |
1 piece |
| electrical connection |
| interface |
Connector: 1 x M12; Contact: gold-plated |