Welcome Customer !

Membership

Help

Shanghai Yibo Electromechanical Equipment Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products
Product Categories

Shanghai Yibo Electromechanical Equipment Co., Ltd

  • E-mail

  • Phone

  • Address

    No. 182 Anbian Road, Putuo District, Shanghai

Contact Now

*Yifumen IFM pressure sensor PN2294

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

*Yifumen IFM Pressure Sensor PN2294 Product Introduction: Programmable switch output, equipped with IO Link and adjustable analog output $r $n red/green display, used to clearly identify the acceptable range

Product Details

*Yifumen IFM pressure sensor PN2294Product Details

*Yifumen IFM pressure sensor PN2294

  • Programmable switch output, equipped with IO Link and adjustable analog output
  • Red/green display, used to clearly indicate the acceptable range
  • The pipeline connection can be rotated for easy arrangement
  • High load protection, long-term stability
  • Durable design, suitable for harsh industrial environments
    Product features
    output signal Switch signal; Analog signal; IO-Link; (configurable)
    measurement range
    -1...10 bar -14.6...145 psi -100...1000 kPa -0.1...1 MPa
    system interface Threaded connection 1/4 'NPT internal thread
    application
    Special performance Gold plated contacts
    Measuring components Ceramic capacitive pressure measuring element
    application For industrial applications
    medium Liquid and gas media
    Medium temperature [° C] -25...80
    Small value of blasting pressure
    150 bar 2175 psi 15 MPa
    compressive strength
    75 bar 1087 psi 7.5 Mpa
    Vacuum resistance [mbar] -1000
    pressure Relative pressure; vacuum
    Maximum allowable work pressure (for applications that comply with CRN standards)
    50 bar 725 psi 5 MPa
    Electrical data
    Working voltage [V] 18... 30 DC; (compliant with EN 50178 SELV/PELV standard)
    Current loss [mA] < 35
    Insulation resistance small value [M Ω] 100; (500 V DC)
    Protection level III
    Reverse phase protection have
    Startup delay time [s] 0.3
    Watchdog Integrated Watchdog Circuit have
    Overall input/output
    Total number of inputs and outputs Number of digital outputs: 2; Analog output quantity: 1
    output
    Output quantity 2
    output signal Switch signal; Analog signal; IO-Link; (configurable)
    Electrical Design PNP/NPN
    Number of digital outputs 2
    output function Normally open/normally closed; (Parameters can be set)
    Switching output DC voltage drop large value [V] 2
    Continuous current load of switch output DC [mA] 250
    Switching frequency DC [Hz] < 500
    Simulated output quantity 1
    Analog current output [mA] 4...20; (Adjustable range 1:5)
    Load maximum value [Ω] 500
    Analog voltage output [V] 0...10; (Adjustable range 1:5)
    Load resistance small value [Ω] 2000
    short circuit protection have
    Short circuit protection type pulse
    overload protection have
    Measurement/Setting Range
    measurement range
    -1...10 bar -14.6...145 psi -100...1000 kPa -0.1...1 MPa
    Switch point, SP
    -0.94...10 bar -13.6...145 psi -0.094...1 MPa
    Recovery point, rP
    -0.98...9.96 bar -14.2...144.4 psi -0.098...0.996 MPa
    Starting point of measurement value
    -1...8 bar -14.6...116 psi -0.1...0.8 MPa
    Measurement endpoint
    1...10 bar 14.6...145 psi 0.1...1 MPa
    Set step distance
    0.02 bar 0.2 psi 0.002 MPa
    Accuracy/Deviation
    Switch point accuracy [% of measurement range value] < ± 0,4; (Turn down 1:1)
    Repetitive accuracy [% of measurement range value] < ± 0,1; (Temperature fluctuation<10 K; Turn down 1:1)
    Characteristic curve deviation [% of measurement range value] < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL=Best Fit Straight Line; LS=Limit Point Setting)
    Lag deviation [% of measurement range value] < ± 0,1; (Turn down 1:1)
    Long term stability [% of measurement range value] < ± 0,05; (Turn down 1:1; every 6 months)
    Temperature coefficient zero point [percentage of measurement range value/10 K] < ± 0,2; (-0...80 °C)
    Temperature coefficient range [percentage of measurement range value/10 K] < ± 0,2; (-0...80 °C)
    reaction time
    Reaction time [ms] < 1.5
    Programmable delay time dS, dr [s] 0...50
    Damping dAP [s] for switch output 0...4
    Damping for analog output (dAA) [s] 0...4
    Simulated output response time large value [ms] 3
    Software/Programming
    Parameter Settings Delay/Window; Normally open/normally closed; ON delay, turn off delay; Damping; Display unit; Current/voltage output
    interface
    communication interface IO-Link
    Transfer type COM2 (38,4 kBaud)
    IO-Link revision 1.1
    SDCI standard IEC 61131-9
    appearance Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
    SIO mode have
    Required Material Port Type A
    Simulated process data 1
    Two digit output process data 2
    Processing cycle small value [ms] 2.3
    Supported DeviceIDs
    Operation mode Deviceid
    default 473
    working conditions
    Environmental temperature [° C] -25...80
    Storage temperature [° C] -40...100
    Shell protection level IP 65; IP 67
    Certification/Testing
    EMC Electromagnetic Compatibility
    DIN EN 61000-6-2
    DIN EN 61000-6-3
    impact-resistant
    DIN EN 60068-2-27 50 g (11 ms)
    earthquake resistance
    DIN EN 60068-2-6 20 g (10...2000 Hz)
    MTTF [year] 138
    UL Certification
    UL certification number J012
    Pressure Equipment Directive Good engineering practices; Can be used for Group 2 fluids; According to the fluid requirements of fluid group 1
    Mechanical technical data
    Weight [g] 221.5
    raw materials 不锈钢 (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC
    Materials (wet parts) Stainless steel (1.4404/316L); Al2O3 (ceramic); FKM
    Switch action lifespan 100 million
    Tightening torque [Nm] > 50; (Depending on lubrication, sealing, and pressure rating)
    system interface Threaded connection 1/4 'NPT internal thread
    Integrated limiter component No (can be modified)
    Display/operating components
    display
    display unit 3 x LED, Green (bar, psi, MPa)
    switch status 2 x LED, yellow
    measured value Alphanumeric display, red/green 4-digit number
    annotation
    packaging unit 1 piece
    electrical connection
    interface Connector: 1 x M12; Contact: gold-plated