| Product features |
| output signal |
Switch signal; Analog signal; IO-Link; (configurable) |
| measurement range |
| -1...10 bar |
-14.6...145 psi |
-100...1000 kPa |
-0.1...1 MPa |
|
| system interface |
Threaded connection 1/4 'NPT internal thread |
| application |
| Special performance |
Gold plated contacts |
| Measuring components |
Ceramic capacitive pressure measuring element |
| application |
For industrial applications |
| medium |
Liquid and gas media |
| Medium temperature [° C] |
-25...80 |
| Small value of blasting pressure |
|
| compressive strength |
|
| Vacuum resistance [mbar] |
-1000 |
| pressure |
Relative pressure; vacuum |
| Maximum allowable work pressure (for applications that comply with CRN standards) |
|
| Electrical data |
| Working voltage [V] |
18... 30 DC; (compliant with EN 50178 SELV/PELV standard) |
| Current loss [mA] |
< 35 |
| Insulation resistance small value [M Ω] |
100; (500 V DC) |
| Protection level |
III |
| Reverse phase protection |
have |
| Startup delay time [s] |
0.3 |
| Watchdog Integrated Watchdog Circuit |
have |
| Overall input/output |
| Total number of inputs and outputs |
Number of digital outputs: 2; Analog output quantity: 1 |
| output |
| Output quantity |
2 |
| output signal |
Switch signal; Analog signal; IO-Link; (configurable) |
| Electrical Design |
PNP/NPN |
| Number of digital outputs |
2 |
| output function |
Normally open/normally closed; (Parameters can be set) |
| Switching output DC voltage drop large value [V] |
2 |
| Continuous current load of switch output DC [mA] |
250 |
| Switching frequency DC [Hz] |
< 500 |
| Simulated output quantity |
1 |
| Analog current output [mA] |
4...20; (Adjustable range 1:5) |
| Load maximum value [Ω] |
500 |
| Analog voltage output [V] |
0...10; (Adjustable range 1:5) |
| Load resistance small value [Ω] |
2000 |
| short circuit protection |
have |
| Short circuit protection type |
pulse |
| overload protection |
have |
| Measurement/Setting Range |
| measurement range |
| -1...10 bar |
-14.6...145 psi |
-100...1000 kPa |
-0.1...1 MPa |
|
| Switch point, SP |
| -0.94...10 bar |
-13.6...145 psi |
-0.094...1 MPa |
|
| Recovery point, rP |
| -0.98...9.96 bar |
-14.2...144.4 psi |
-0.098...0.996 MPa |
|
| Starting point of measurement value |
| -1...8 bar |
-14.6...116 psi |
-0.1...0.8 MPa |
|
| Measurement endpoint |
| 1...10 bar |
14.6...145 psi |
0.1...1 MPa |
|
| Set step distance |
| 0.02 bar |
0.2 psi |
0.002 MPa |
|
| Accuracy/Deviation |
| Switch point accuracy [% of measurement range value] |
< ± 0,4; (Turn down 1:1) |
| Repetitive accuracy [% of measurement range value] |
< ± 0,1; (Temperature fluctuation<10 K; Turn down 1:1) |
| Characteristic curve deviation [% of measurement range value] |
< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL=Best Fit Straight Line; LS=Limit Point Setting) |
| Lag deviation [% of measurement range value] |
< ± 0,1; (Turn down 1:1) |
| Long term stability [% of measurement range value] |
< ± 0,05; (Turn down 1:1; every 6 months) |
| Temperature coefficient zero point [percentage of measurement range value/10 K] |
< ± 0,2; (-0...80 °C) |
| Temperature coefficient range [percentage of measurement range value/10 K] |
< ± 0,2; (-0...80 °C) |
| reaction time |
| Reaction time [ms] |
< 1.5 |
| Programmable delay time dS, dr [s] |
0...50 |
| Damping dAP [s] for switch output |
0...4 |
| Damping for analog output (dAA) [s] |
0...4 |
| Simulated output response time large value [ms] |
3 |
| Software/Programming |
| Parameter Settings |
Delay/Window; Normally open/normally closed; ON delay, turn off delay; Damping; Display unit; Current/voltage output |
| interface |
| communication interface |
IO-Link |
| Transfer type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| appearance |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
| SIO mode |
have |
| Required Material Port Type |
A |
| Simulated process data |
1 |
| Two digit output process data |
2 |
| Processing cycle small value [ms] |
2.3 |
| Supported DeviceIDs |
| Operation mode |
Deviceid |
| default |
473 |
|
| working conditions |
| Environmental temperature [° C] |
-25...80 |
| Storage temperature [° C] |
-40...100 |
| Shell protection level |
IP 65; IP 67 |
| Certification/Testing |
| EMC Electromagnetic Compatibility |
| DIN EN 61000-6-2 |
|
| DIN EN 61000-6-3 |
|
|
| impact-resistant |
| DIN EN 60068-2-27 |
50 g (11 ms) |
|
| earthquake resistance |
| DIN EN 60068-2-6 |
20 g (10...2000 Hz) |
|
| MTTF [year] |
138 |
| UL Certification |
| UL certification number |
J012 |
|
| Pressure Equipment Directive |
Good engineering practices; Can be used for Group 2 fluids; According to the fluid requirements of fluid group 1 |
| Mechanical technical data |
| Weight [g] |
221.5 |
| raw materials |
不锈钢 (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC |
| Materials (wet parts) |
Stainless steel (1.4404/316L); Al2O3 (ceramic); FKM |
| Switch action lifespan |
100 million |
| Tightening torque [Nm] |
> 50; (Depending on lubrication, sealing, and pressure rating) |
| system interface |
Threaded connection 1/4 'NPT internal thread |
| Integrated limiter component |
No (can be modified) |
| Display/operating components |
| display |
| display unit |
3 x LED, Green (bar, psi, MPa) |
| switch status |
2 x LED, yellow |
| measured value |
Alphanumeric display, red/green 4-digit number |
|
| annotation |
| packaging unit |
1 piece |
| electrical connection |
| interface |
Connector: 1 x M12; Contact: gold-plated |