| Product features |
| output signal |
switch signal |
| measurement range |
|
| system interface |
Threaded connection G 1/4 external thread internal thread: M5 |
| application |
| application |
For industrial applications |
| medium |
Liquid and gas media |
| Medium temperature [° C] |
-25...80 |
| Small value of blasting pressure |
|
| compressive strength |
|
| pressure |
relative pressure |
| Electrical data |
| Working voltage [V] |
9.6...32 DC |
| Current loss [mA] |
< 25 |
| Insulation resistance small value [M Ω] |
100; (500 V DC) |
| protection level |
III |
| Reverse phase protection |
have |
| Overall input/output |
| Total number of inputs and outputs |
Number of digital outputs: 2 |
| output |
| output quantity |
2 |
| output signal |
switch signal |
| Electrical Design |
PNP |
| Number of digital outputs |
2 |
| Output function |
NC+NO |
| Switching output DC voltage drop large value [V] |
2 |
| Continuous current load of switch output DC [mA] |
500 |
| Switching frequency DC [Hz] |
100 |
| short circuit protection |
have |
| Short circuit protection type |
pulse |
| overload protection |
have |
| Measurement/Setting Range |
| measurement range |
|
| Switch point, SP |
| 5...100 bar |
75...1450 psi |
|
| Recovery point, rP |
|
| Accuracy/Deviation |
| Switch point accuracy [percentage of final value] |
< ± 2,5; (Adjustment accuracy) |
| Repetitive accuracy [percentage of final value] |
< ± 0,5; (Temperature fluctuation<10 K) |
| Characteristic curve deviation [percentage of final value] |
< ± 1,5 (BFSL) / < ± 2,5 (LS); (BFSL=Best Fit Straight Line; LS=Limit Point Setting) |
| Temperature change rate/10 K |
< ± 0.5 |
| Software/Programming |
| Switch point adjustment |
Rotating Ring |
| working conditions |
| Environmental temperature [° C] |
-25...80 |
| Storage temperature [° C] |
-40...100 |
| Shell protection level |
IP 67 |
| Certification/Testing |
| EMC electromagnetic compatibility |
| DIN EN 61000-6-2 |
|
| DIN EN 61000-6-3 |
|
|
| impact-resistant |
| DIN IEC 68-2-27 |
50 g (11 ms) |
|
| earthquake resistance |
| DIN IEC 68-2-6 |
20 g (10...2000 Hz) |
|
| MTTF [year] |
450 |
| Pressure Equipment Directive |
Good engineering practices; Can be used for Group 2 fluids; According to the fluid requirements of fluid group 1 |
| Mechanical technical data |
| Weight [K40] |
94 |
| raw materials |
PBT; PC; FKM; Stainless steel (1.4404/316L) |
| Materials (wet parts) |
Stainless steel (1.4404/316L); FKM |
| Switch action lifespan |
fifty million |
| Tightening torque [Nm] |
25 |
| system interface |
Threaded connection G 1/4 external thread internal thread: M5 |
| Integrated limiter component |
No (can be modified) |
| Display/operating components |
| display |
| operation |
LED, green |
| switch status |
LED, yellow |
|
| With scale |
have |
| annotation |
| packaging unit |
1 piece |
| electrical connection |
| interface |
Connector: 1 x M12 |