| Product features |
| output signal |
analog signal |
| measurement range |
| 0...250 bar |
0...3625 psi |
0...25 MPa |
|
| system interface |
Threaded connection G 1/4 internal thread |
| application |
| Special performance |
Gold plated contacts |
| application |
For industrial applications |
| medium |
Liquid and gas media |
| Conditionally applicable to |
For gas media with pressure>25 bar, only based on demand |
| Medium temperature [° C] |
-25...90; (Based on demand only: -40... 90 ° C) |
| Small value of blasting pressure |
|
| compressive strength |
|
| pressure |
relative pressure |
| Electrical data |
| Working voltage [V] |
16...32 DC |
| Current loss [mA] |
< 18 |
| Insulation resistance small value [M Ω] |
100; (500 V DC) |
| protection level |
III |
| Reverse phase protection |
have |
| Overall input/output |
| Total number of inputs and outputs |
Analog output quantity: 1 |
| output |
| output quantity |
1 |
| output signal |
analog signal |
| Simulated output quantity |
1 |
| Analog voltage output [V] |
0...10 |
| Load resistance small value [Ω] |
2000 |
| overload protection |
have |
| Measurement/Setting Range |
| measurement range |
| 0...250 bar |
0...3625 psi |
0...25 MPa |
|
| Accuracy/Deviation |
| Repetitive accuracy [% of measurement range value] |
< 0,1; (Temperature fluctuation<10 K) |
| Characteristic curve deviation [% of measurement range value] |
< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL=Best Fit Straight Line; LS=Limit Point Setting) |
| Long term stability [% of measurement range value] |
< ± 0,05; (Every 6 months) |
| Temperature coefficient zero point [percentage of measurement range value/10 K] |
0,1; (0...80 °C) |
| Temperature coefficient range [percentage of measurement range value/10 K] |
0,2; (0...80 °C) |
| reaction time |
| Step function response time simulation output [ms] |
3 |
| working conditions |
| Environmental temperature [° C] |
-25...80 |
| Storage temperature [° C] |
-40...100 |
| Shell protection level |
IP 68; IP 69K |
| Certification/Testing |
| EMC electromagnetic compatibility |
| EN 61000-4-2 ESD |
4 kV CD / 8 kV AD |
| EN 61000-4-3 HF Electromagnetic Field Radiation |
30 V/m |
| EN 61000-4-4 Burst |
2 kV |
| EN 61000-4-6 Conducted Immunity to Radio Frequency Field Induction |
10 V |
| Interference radiation |
According to the highway vehicle standard 004/104/EC |
| CISPR 25 |
|
| Immunity |
According to the highway vehicle standard 004/104/EC |
| ISO 11452-2 HF Electromagnetic Field Radiation |
100 V/m |
| ISO 7637-2 pulse |
Strict Level 4 |
|
| impact-resistant |
| DIN EN 60068-2-27 |
50 g (11 ms) |
| DIN EN 61373 |
Category 3 |
|
| earthquake resistance |
| DIN EN 60068-2-6 |
20 g (10...2000 Hz) |
| DIN EN 61373 |
Category 2 |
|
| MTTF [year] |
478 |
| UL Certification |
| UL certification number |
J008 |
|
| Pressure Equipment Directive |
Good engineering practices; Can be used for Group 2 fluids; According to the fluid requirements of fluid group 1 |
| railway application |
| DIN EN 50155 / IEC 60571 |
Class T3, C1, S1 |
|
| Mechanical technical data |
| Weight [g] |
223.5 |
| raw materials |
Stainless steel (1.4404/316L); FKM; PA; EPDM/X |
| Materials (wet parts) |
Stainless steel (1.4305/303); Ceramics; FKM |
| Switch action lifespan |
100 million |
| system interface |
Threaded connection G 1/4 internal thread |
| Integrated limiter component |
No (can be modified) |
| annotation |
| packaging unit |
1 piece |
| electrical connection |
| interface |
Connector: 1 x M12; Contact: gold-plated |